EATON NEMA Size 0 Reversing Starter

The EATON NEMA Magnetic Motor Starter: Reversing (SKU AN59BN0T5E005, MPN AN59BN0T5E005) is a three-phase reversing starter with an electronic overload, NEMA Size 0, rated 18 A, and a 24V AC coil. It includes a 1NO…

SKU 3G-OTH-41743

Brand
EATON
Item
NEMA Size 0 Reversing Starter
Part Number
AN59BN0T5E005
Category
Reversing Starters with Electronic Overloads
Available to Order
Also known as:AN59BN0T5E005EATON
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

EATON
Manufacturer Part Number
AN59BN0T5E005
Type
NEMA Size 0, 18 A
Phase
Three
Poles
3
AC Coil
24V
Operator
None
Coil Voltage
24V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter: Reversing (SKU AN59BN0T5E005, MPN AN59BN0T5E005) is a three-phase reversing starter with an electronic overload, NEMA Size 0, rated 18 A, and a 24V AC coil. It includes a 1NO auxiliary contact and a pilot light for signaling, with no operator or operator controls.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter used for?

The EATON NEMA Magnetic Motor Starter is used for reversing three-phase motors in industrial applications such as conveyors, hoists, and pumps. It provides overload protection via an electronic overload and includes a pilot light for status signaling.

What are the specifications of the EATON AN59BN0T5E005 reversing starter?

The EATON AN59BN0T5E005 is a NEMA Size 0 reversing starter rated 18 A with a 24V AC coil. It has three poles, includes one normally open auxiliary contact, and features an electronic overload with no thermal units required. A pilot light is built in for signaling.

Where to buy the EATON AN59BN0T5E005 worldwide?

3G Electric supplies the EATON AN59BN0T5E005 reversing starter worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to select the correct EATON NEMA reversing starter for a motor?

Select the EATON reversing starter by matching the motor's full-load current (FLC) to the starter's ampere rating—here 18 A for NEMA Size 0. Ensure coil voltage matches your control circuit (24V AC). The electronic overload eliminates the need for separate thermal units.

Used in

Common applications for EATON
Commercial electrical distribution — Eaton GHB Series miniature circuit breakers for panelboard overcurrent protection
Industrial motor control — Eaton DS7 soft start for three-phase motor starting in pumps and fans
HVAC and process control — Eaton PowerXL DA1 variable frequency drive for speed control of three-phase AC motors
Machine status indication — Eaton SL4 series tower light modules and mounting bases for visual signaling
Fire alarm systems — Eaton ELSTR and ELSTR-N strobes for wall-mount visual notification
Data center power management — Eaton WEBCARDLXE network management card for remote UPS monitoring
Not sure this is the right part? Photo-identify it→

EATON Products

3G Electric supplies EATON reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from EATON

View all EATON parts →
Three-phase reversing starter with electronic overload protection, NEMA Size 0, rated 18 A. Features a 208V AC coil, pilot light for signaling, and one normally open auxiliary contact. Suitable for reversing direction of three-phase motors in applications such as conveyors, hoists, and pumps
EATON
Three-phase reversing starter with electronic overload protection, NEMA Size 0, rated 18 A. Features a 208V AC coil, pilot light for signaling, and one normally open auxiliary contact. Suitable for reversing direction of three-phase motors in applications such as conveyors, hoists, and pumps
Three-phase NEMA Size 5 reversing starter rated 270 A with 24V AC coil. Includes electronic overload, pilot light, and one normally open auxiliary contact. Used to control forward and reverse rotation of three-phase AC motors in applications such as conveyors, hoists, and pumps
EATON
Three-phase NEMA Size 5 reversing starter rated 270 A with 24V AC coil. Includes electronic overload, pilot light, and one normally open auxiliary contact. Used to control forward and reverse rotation of three-phase AC motors in applications such as conveyors, hoists, and pumps
Three-phase reversing starter for forward and reverse motor control, rated 45 A at NEMA Size 2. Includes electronic overload protection (no thermal units required), 220/240V AC coil, one normally open auxiliary contact, and a pilot light for signaling. Suitable for applications such as conveyors and hoists
EATON
Three-phase reversing starter for forward and reverse motor control, rated 45 A at NEMA Size 2. Includes electronic overload protection (no thermal units required), 220/240V AC coil, one normally open auxiliary contact, and a pilot light for signaling. Suitable for applications such as conveyors and hoists

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first