Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

EATON Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 3, 90 A - Reversing Starters with Electronic Overloads
EATONReversing Starters with Electronic Overloads

EATON Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 3, 90 A

The EATON NEMA Magnetic Motor Starter: Reversing (SKU AN59KN0E5E100, MPN AN59KN0E5E100) is a three-phase reversing starter with an electronic overload, NEMA Size 3, rated 90 A, and a 208V AC coil. It includes a pilot…

SKU 3G-OTH-40566

Brand
EATON
Item
Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 3, 90 A
Category
Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

EATON
Manufacturer Part Number
AN59KN0E5E100
Type
NEMA Size 3, 90 A
Phase
Three
Poles
3
AC Coil
208V
Operator
None
Coil Voltage
208V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter: Reversing (SKU AN59KN0E5E100, MPN AN59KN0E5E100) is a three-phase reversing starter with an electronic overload, NEMA Size 3, rated 90 A, and a 208V AC coil. It includes a pilot light and one normally open auxiliary contact, with no operator or operator controls.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter reversing used for?

This EATON reversing starter controls three-phase motors in applications requiring forward and reverse operation, such as conveyors, hoists, and industrial machinery. It includes an electronic overload for motor protection and a pilot light for status indication.

What are the specifications of the EATON AN59KN0E5E100 motor starter?

The EATON AN59KN0E5E100 is a NEMA Size 3 reversing starter rated 90 A, 3 poles, with a 208V AC coil. It includes one normally open auxiliary contact and a pilot light. The electronic overload eliminates the need for separate thermal units.

Where to buy the EATON NEMA Size 3 reversing starter worldwide?

3G Electric supplies the EATON NEMA Size 3 reversing starter (MPN AN59KN0E5E100) worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this industrial motor starter.

How to select the correct NEMA size for a reversing motor starter?

Select NEMA size based on motor full-load current and voltage. For a 90 A rating, NEMA Size 3 is appropriate. Ensure coil voltage matches your control circuit (208V AC here). EATON starters include electronic overloads, simplifying setup by eliminating thermal unit selection.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 3, 90 A, 480V AC Coil (MPN AN59KN0C5E100)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 3, 90 A, 480V AC Coil (MPN AN59KN0C5E100)
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 3, 90 A, 120V AC Coil (MPN AN59KN0A5E100)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 3, 90 A, 120V AC Coil (MPN AN59KN0A5E100)
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 1, 27 A, 208V AC Coil (MPN AN59DN0E5E020)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 1, 27 A, 208V AC Coil (MPN AN59DN0E5E020)
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 5, 270 A, 208V AC Coil (MPN AN59SN0E5G300)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 5, 270 A, 208V AC Coil (MPN AN59SN0E5G300)
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN AN59GN0E5E005)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN AN59GN0E5E005)
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN AN59GN0E5E020)
EATON
EATON NEMA Magnetic Motor Starter: Reversing, 3 Poles, NEMA Size 2, 45 A, 208V AC Coil (MPN AN59GN0E5E020)

More from EATON

View all EATON parts
Three-phase reversing starter with electronic overload protection, rated 27 A, NEMA Size 1. Includes a 220/240V AC coil, one normally open auxiliary contact, and a pilot light for status indication. No thermal units required. Suitable for controlling motors in forward/reverse applications such as conveyors and hoists
EATON
Three-phase reversing starter with electronic overload protection, rated 27 A, NEMA Size 1. Includes a 220/240V AC coil, one normally open auxiliary contact, and a pilot light for status indication. No thermal units required. Suitable for controlling motors in forward/reverse applications such as conveyors and hoists
Three-phase reversing motor starter, NEMA Size 2, rated 45 A. Includes electronic overload protection (no thermal units required), 1NO auxiliary contact, and pilot light. Coil voltage 220/240V AC. Used for starting, stopping, and reversing three-phase motors in applications such as conveyors, pumps, and machinery requiring forward/reverse operation
EATON
Three-phase reversing motor starter, NEMA Size 2, rated 45 A. Includes electronic overload protection (no thermal units required), 1NO auxiliary contact, and pilot light. Coil voltage 220/240V AC. Used for starting, stopping, and reversing three-phase motors in applications such as conveyors, pumps, and machinery requiring forward/reverse operation
Three-phase reversing starter with electronic overload, NEMA Size 0, rated 18 A. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for signaling. No thermal units required. Used for reversing direction of three-phase motors in applications such as conveyors, pumps, and hoists
EATON
Three-phase reversing starter with electronic overload, NEMA Size 0, rated 18 A. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for signaling. No thermal units required. Used for reversing direction of three-phase motors in applications such as conveyors, pumps, and hoists
Three-phase reversing starter, NEMA Size 0, rated 18 A, with 110/120V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light. Used for reversing three-phase motors in applications such as conveyors, hoists, and pumps
EATON
Three-phase reversing starter, NEMA Size 0, rated 18 A, with 110/120V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light. Used for reversing three-phase motors in applications such as conveyors, hoists, and pumps
Three-phase NEMA Size 3 reversing starter rated 90 A with a 220/240V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates the need for thermal units. Used to start, stop, and reverse motors in applications such as conveyors, pumps, and fans
EATON
Three-phase NEMA Size 3 reversing starter rated 90 A with a 220/240V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates the need for thermal units. Used to start, stop, and reverse motors in applications such as conveyors, pumps, and fans
Three-phase NEMA Size 1 reversing starter rated 27 A with 110/120V AC coil. Electronic overload protection eliminates need for thermal units. Includes pilot light for status indication and one normally open auxiliary contact. Suitable for reversing direction of three-phase motors in industrial applications such as conveyors, pumps, and hoists
EATON
Three-phase NEMA Size 1 reversing starter rated 27 A with 110/120V AC coil. Electronic overload protection eliminates need for thermal units. Includes pilot light for status indication and one normally open auxiliary contact. Suitable for reversing direction of three-phase motors in industrial applications such as conveyors, pumps, and hoists
Three-phase NEMA Size 1 reversing starter rated 27 A with a 110/120V AC coil. Features an electronic overload (no thermal units required), a pilot light, and one normally open auxiliary contact. Suitable for forward and reverse control of three-phase motors in industrial applications such as conveyors, hoists, and pumps
EATON
Three-phase NEMA Size 1 reversing starter rated 27 A with a 110/120V AC coil. Features an electronic overload (no thermal units required), a pilot light, and one normally open auxiliary contact. Suitable for forward and reverse control of three-phase motors in industrial applications such as conveyors, hoists, and pumps
Three-phase reversing starter for motor control, NEMA Size 0, rated 9 A, with 220/240V AC coil. Includes electronic overload protection, pilot light, and one normally open auxiliary contact. No thermal units required. Typical applications include conveyors, hoists, and pumps
EATON
Three-phase reversing starter for motor control, NEMA Size 0, rated 9 A, with 220/240V AC coil. Includes electronic overload protection, pilot light, and one normally open auxiliary contact. No thermal units required. Typical applications include conveyors, hoists, and pumps