Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

EATON IEC FAZ-D3/2-NA D-Curve 2-Pole UL489 Miniature Circuit Breaker - D-Curve, 2-Pole UL489 DIN Rail-Mount Miniature Circuit Breakers
EATON IECD-Curve, 2-Pole UL489 DIN Rail-Mount Miniature Circuit Breakers

EATON IEC FAZ-D3/2-NA D-Curve 2-Pole UL489 Miniature Circuit Breaker

The EATON IEC FAZ-D3/2-NA is a 3 A, D-Curve, 2-pole UL489 miniature circuit breaker designed for DIN-rail mounting. It is rated at 48/96V DC and 277/480V AC with a 10kA interrupting capacity at 277/480V AC, and…

SKU 3G-OTH-133190

Also listed as: FAZD32NA · FAZ D3 2 NA · FAZ-D3-2-NA

Brand
EATON IEC
Item
FAZ-D3/2-NA D-Curve 2-Pole UL489 Miniature Circuit Breaker
Category
D-Curve, 2-Pole UL489 DIN Rail-Mount Miniature Circuit Breakers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

EATON IEC
Manufacturer Part Number
FAZ-D3/2-NA
Type
10kA at 277/480V AC, Screw Clamp, FAZ-NA
DC
48/96V

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON IEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON IEC FAZ-D3/2-NA is a 3 A, D-Curve, 2-pole UL489 miniature circuit breaker designed for DIN-rail mounting. It is rated at 48/96V DC and 277/480V AC with a 10kA interrupting capacity at 277/480V AC, and features screw-clamp terminals.

Frequently Asked Questions

What is the EATON IEC FAZ-D3/2-NA miniature circuit breaker used for?

The EATON IEC FAZ-D3/2-NA is a 3 A, D-Curve, 2-pole UL489 miniature circuit breaker used for overcurrent protection in industrial control panels, motor circuits, and DC power systems. It is designed for DIN-rail mounting and handles 48/96V DC or 277/480V AC applications.

What are the specifications of the EATON FAZ-D3/2-NA?

The EATON FAZ-D3/2-NA is rated at 3 A, 48/96V DC, and 277/480V AC with a 10kA interrupting capacity at 277/480V AC. It features a D-Curve trip characteristic, 2 poles, screw-clamp terminals, and UL489 certification for DIN-rail mounting.

Where to buy the EATON FAZ-D3/2-NA worldwide?

You can source the EATON FAZ-D3/2-NA worldwide through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the EATON FAZ-D3/2-NA miniature circuit breaker?

Install the EATON FAZ-D3/2-NA by snapping it onto a standard DIN rail. Ensure the circuit is de-energized, then connect conductors to the screw-clamp terminals using the specified torque. Follow NEC and local codes for wire sizing and overcurrent protection.

Used in

Common applications for EATON IEC
Industrial control panels — Eaton FAZ-NA miniature circuit breakers for branch circuit protection of PLCs and drives
Motor control centers — Eaton FAZ D-curve supplementary protectors for motor starter overcurrent protection
Building electrical distribution — Eaton IEC miniature circuit breakers for lighting and receptacle circuits in commercial facilities
OEM machinery — Eaton FAZ series supplementary protectors for equipment-level protection in packaging and processing machines
DC control systems — Eaton FAZ-NA miniature circuit breakers rated 48/96 V DC for relay and solenoid circuits
Renewable energy installations — Eaton IEC miniature circuit breakers for inverter and battery bank overcurrent protection

EATON IEC Products

3G Electric supplies EATON IEC d-curve, 2-pole ul489 din rail-mount miniature circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
D-Curve, 2-pole miniature circuit breaker rated 4 A, with a breaking capacity of 10 kA at 277/480 V AC. Suitable for overcurrent protection in industrial electrical systems. Features screw clamp terminals and DIN rail mounting. Rated for 48/96 V DC and 277/480 V AC
EATON IEC
D-Curve, 2-pole miniature circuit breaker rated 4 A, with a breaking capacity of 10 kA at 277/480 V AC. Suitable for overcurrent protection in industrial electrical systems. Features screw clamp terminals and DIN rail mounting. Rated for 48/96 V DC and 277/480 V AC
This 2-pole miniature circuit breaker features a D-curve trip characteristic for overcurrent protection in circuits with high inrush currents, such as motor loads. Rated 2 A with a 10kA interrupting capacity at 277/480V AC and suitable for 48/96V DC applications. Equipped with screw clamp terminals for secure wiring. DIN rail mountable for use in industrial control panels and power distribution systems
EATON IEC
This 2-pole miniature circuit breaker features a D-curve trip characteristic for overcurrent protection in circuits with high inrush currents, such as motor loads. Rated 2 A with a 10kA interrupting capacity at 277/480V AC and suitable for 48/96V DC applications. Equipped with screw clamp terminals for secure wiring. DIN rail mountable for use in industrial control panels and power distribution systems
This D-Curve miniature circuit breaker is rated 10 A and features a 2-pole configuration for DIN rail mounting. It provides overcurrent protection for industrial control panels, machinery, and power distribution systems, with a 10kA interrupting capacity at 277/480V AC and suitability for DC circuits up to 48/96V. Terminals are screw clamp type
EATON IEC
This D-Curve miniature circuit breaker is rated 10 A and features a 2-pole configuration for DIN rail mounting. It provides overcurrent protection for industrial control panels, machinery, and power distribution systems, with a 10kA interrupting capacity at 277/480V AC and suitability for DC circuits up to 48/96V. Terminals are screw clamp type
D-Curve, 2-pole UL489 DIN rail-mount miniature circuit breaker rated at 5 A. Provides overcurrent and short-circuit protection for branch circuits in AC and DC applications. Features screw clamp terminals and a breaking capacity of 10kA at 277/480V AC. Suitable for high-inrush loads such as motors and transformers in industrial control panels, HVAC equipment, and machinery
EATON IEC
D-Curve, 2-pole UL489 DIN rail-mount miniature circuit breaker rated at 5 A. Provides overcurrent and short-circuit protection for branch circuits in AC and DC applications. Features screw clamp terminals and a breaking capacity of 10kA at 277/480V AC. Suitable for high-inrush loads such as motors and transformers in industrial control panels, HVAC equipment, and machinery
D-Curve, 2-pole UL489 DIN rail-mount miniature circuit breaker rated at 8 A. Supports 48/96V DC and 277/480V AC with a 10kA interrupting capacity at 277/480V AC. Features screw clamp terminals. Suitable for branch circuit protection in industrial control panels, HVAC equipment, and machinery
EATON IEC
D-Curve, 2-pole UL489 DIN rail-mount miniature circuit breaker rated at 8 A. Supports 48/96V DC and 277/480V AC with a 10kA interrupting capacity at 277/480V AC. Features screw clamp terminals. Suitable for branch circuit protection in industrial control panels, HVAC equipment, and machinery
D-curve, 2-pole UL489 miniature circuit breaker rated 6 A. Interrupting capacity 10 kA at 277/480 V AC; also rated 48/96 V DC. Screw clamp terminals. For overcurrent protection in industrial and commercial panels handling high inrush loads such as motors and transformers
EATON IEC
D-curve, 2-pole UL489 miniature circuit breaker rated 6 A. Interrupting capacity 10 kA at 277/480 V AC; also rated 48/96 V DC. Screw clamp terminals. For overcurrent protection in industrial and commercial panels handling high inrush loads such as motors and transformers

More from EATON IEC

View all EATON IEC parts
D-Curve, 2-pole UL489 miniature circuit breaker rated at 1 A. Provides overcurrent and short-circuit protection for branch circuits and equipment in 277/480V AC systems with a 10kA interrupting capacity. Also rated for 48/96V DC applications. Features screw clamp terminals and DIN rail mounting
EATON IEC
D-Curve, 2-pole UL489 miniature circuit breaker rated at 1 A. Provides overcurrent and short-circuit protection for branch circuits and equipment in 277/480V AC systems with a 10kA interrupting capacity. Also rated for 48/96V DC applications. Features screw clamp terminals and DIN rail mounting
D-Curve, 2-pole UL489 miniature circuit breaker rated 13 A. Interrupting capacity 14 kA at 277/480 V AC; suitable for 48/96 V DC applications. Screw clamp terminals. For DIN rail mounting in branch circuit protection of industrial control panels, HVAC equipment, and motor starter applications
EATON IEC
D-Curve, 2-pole UL489 miniature circuit breaker rated 13 A. Interrupting capacity 14 kA at 277/480 V AC; suitable for 48/96 V DC applications. Screw clamp terminals. For DIN rail mounting in branch circuit protection of industrial control panels, HVAC equipment, and motor starter applications
This 2-pole miniature circuit breaker features a D-curve trip characteristic for high inrush loads. Rated 15 A with 14kA interrupting capacity at 277/480V AC and 48/96V DC. Screw-clamp terminals ensure secure wiring. UL489 listed for branch circuit protection in industrial control panels and equipment
EATON IEC
This 2-pole miniature circuit breaker features a D-curve trip characteristic for high inrush loads. Rated 15 A with 14kA interrupting capacity at 277/480V AC and 48/96V DC. Screw-clamp terminals ensure secure wiring. UL489 listed for branch circuit protection in industrial control panels and equipment
This D-curve, 2-pole miniature circuit breaker is rated 32 A and UL489 listed for DIN-rail mounting. It provides overcurrent protection for branch circuits in industrial control panels, HVAC equipment, and machinery. The breaker supports 48/96V DC and 277/480V AC systems with a 10kA interrupting capacity at 277/480V AC. Connection is via screw clamp terminals
EATON IEC
This D-curve, 2-pole miniature circuit breaker is rated 32 A and UL489 listed for DIN-rail mounting. It provides overcurrent protection for branch circuits in industrial control panels, HVAC equipment, and machinery. The breaker supports 48/96V DC and 277/480V AC systems with a 10kA interrupting capacity at 277/480V AC. Connection is via screw clamp terminals
D-Curve, 2-pole UL489 miniature circuit breaker rated 30 A. Provides overcurrent protection for branch circuits in industrial control panels, HVAC equipment, and machinery. Interrupting capacity 10kA at 277/480V AC; also rated 48/96V DC. Screw clamp terminals, DIN rail mount
EATON IEC
D-Curve, 2-pole UL489 miniature circuit breaker rated 30 A. Provides overcurrent protection for branch circuits in industrial control panels, HVAC equipment, and machinery. Interrupting capacity 10kA at 277/480V AC; also rated 48/96V DC. Screw clamp terminals, DIN rail mount
D-Curve miniature circuit breaker for overcurrent protection in industrial and commercial electrical panels. Rated 40A, 48/96V DC, 240V AC, with 10kA breaking capacity at 277/480V AC. 2-pole, UL489 listed, DIN rail mountable with screw clamp terminals. Suitable for high-inrush loads such as motors and transformers
EATON IEC
D-Curve miniature circuit breaker for overcurrent protection in industrial and commercial electrical panels. Rated 40A, 48/96V DC, 240V AC, with 10kA breaking capacity at 277/480V AC. 2-pole, UL489 listed, DIN rail mountable with screw clamp terminals. Suitable for high-inrush loads such as motors and transformers
This D-curve, 2-pole miniature circuit breaker is UL489 listed for DIN rail mounting. Rated 25 A with 10kA interrupting capacity at 277/480V AC and supports 48/96V DC. Screw clamp terminals provide secure connection. Suitable for overcurrent protection in industrial and commercial electrical panels, including motor and lighting circuits
EATON IEC
This D-curve, 2-pole miniature circuit breaker is UL489 listed for DIN rail mounting. Rated 25 A with 10kA interrupting capacity at 277/480V AC and supports 48/96V DC. Screw clamp terminals provide secure connection. Suitable for overcurrent protection in industrial and commercial electrical panels, including motor and lighting circuits
D-Curve, 2-pole miniature circuit breaker rated 7 A, UL489 listed for branch circuit protection. Suitable for 48/96V DC control circuits and 277/480V AC lighting or motor loads. Interrupting capacity 10kA at 277/480V AC. Screw clamp terminals for secure wiring. DIN rail mount
EATON IEC
D-Curve, 2-pole miniature circuit breaker rated 7 A, UL489 listed for branch circuit protection. Suitable for 48/96V DC control circuits and 277/480V AC lighting or motor loads. Interrupting capacity 10kA at 277/480V AC. Screw clamp terminals for secure wiring. DIN rail mount