The EATON Power Defense Molded Case Circuit Breaker (SKU PDG33G0300TFAJ, MPN PDG33G0300TFAJ) is a 300 A rated device on a 600A/Frame 3 frame. It features a fixed instantaneous trip, a maximum AIR rating of 35 kA at…

SKU 3G-OTH-24391

Brand
EATON
Item
Power Defense Molded Case Circuit Breaker
Category
Power Defense Molded Case Circuit Breakers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

EATON
Manufacturer Part Number
PDG33G0300TFAJ
Type
35 kA at 480V AC, Fixed/Adj, ABC, Std Line and Load Lugs, Std
Frame Size
600A/Frame 3
Max. AIR Rating
35 kA at 480V AC
Phase Connection
ABC
Instantaneous Trip
Fixed
Terminal Connection
Standard Line and Load Lugs

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON Power Defense Molded Case Circuit Breaker (SKU PDG33G0300TFAJ, MPN PDG33G0300TFAJ) is a 300 A rated device on a 600A/Frame 3 frame. It features a fixed instantaneous trip, a maximum AIR rating of 35 kA at 480V AC, and ABC phase connection. The breaker comes with standard line and load lugs for terminal connection.

Frequently Asked Questions

What is the EATON Power Defense molded case circuit breaker used for?

The EATON Power Defense molded case circuit breaker is used for overcurrent protection in industrial and commercial electrical distribution systems. It safeguards equipment and wiring from damage due to short circuits or overloads, with a 300 A rating and 35 kA interrupting capacity at 480V AC.

What are the specifications of the EATON PDG33G0300TFAJ circuit breaker?

The EATON PDG33G0300TFAJ is a 300 A rated circuit breaker on a 600A/Frame 3 frame. It has a maximum AIR rating of 35 kA at 480V AC, fixed instantaneous trip, ABC phase connection, and standard line and load lugs for terminal connection. The MPN is PDG33G0300TFAJ.

Where to buy the EATON PDG33G0300TFAJ circuit breaker worldwide?

You can source the EATON PDG33G0300TFAJ circuit breaker through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring the product reaches your facility reliably.

How to select the right EATON Power Defense circuit breaker for your application?

To select the right EATON Power Defense circuit breaker, match the continuous current rating (e.g., 300 A) to your load, verify the interrupting capacity (35 kA at 480V AC) exceeds available fault current, and confirm phase connection (ABC) and terminal type (standard lugs) suit your panel. Consult a licensed engineer for coordination studies.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON power defense molded case circuit breakers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Molded case circuit breaker rated 400 A in a 600 A frame, with a maximum interrupting rating of 35 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for overcurrent protection in electrical distribution systems
EATON
Molded case circuit breaker rated 400 A in a 600 A frame, with a maximum interrupting rating of 35 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for overcurrent protection in electrical distribution systems
EATON Power Defense molded case circuit breaker rated 350 A on a 600A/Frame 3 frame. Provides overcurrent protection with a maximum interrupting rating of 35 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs for terminal connection. Suitable for use in electrical distribution systems for branch circuit and feeder protection
EATON
EATON Power Defense molded case circuit breaker rated 350 A on a 600A/Frame 3 frame. Provides overcurrent protection with a maximum interrupting rating of 35 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs for terminal connection. Suitable for use in electrical distribution systems for branch circuit and feeder protection
Molded case circuit breaker rated 400 A in a 600A/Frame 3 frame. Provides overcurrent protection with a maximum interrupting rating of 65 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for use in panelboards, switchboards, and motor control centers
EATON
Molded case circuit breaker rated 400 A in a 600A/Frame 3 frame. Provides overcurrent protection with a maximum interrupting rating of 65 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Suitable for use in panelboards, switchboards, and motor control centers
EATON Circuit Breaker: 300 A Amps, 65 kA at 480V AC, Fixed/Adj, ABC, Std Line and Load Lugs, Std (MPN PDG33M0300TFAJ)
EATON
EATON Circuit Breaker: 300 A Amps, 65 kA at 480V AC, Fixed/Adj, ABC, Std Line and Load Lugs, Std (MPN PDG33M0300TFAJ)
Molded case circuit breaker rated 250 A on a 600A/Frame 3 frame. Provides overcurrent protection with a maximum AIR rating of 35 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs for terminal connection. Suitable for branch circuit, feeder, and equipment protection in electrical distribution systems
EATON
Molded case circuit breaker rated 250 A on a 600A/Frame 3 frame. Provides overcurrent protection with a maximum AIR rating of 35 kA at 480V AC. Features fixed instantaneous trip, ABC phase connection, and standard line and load lugs for terminal connection. Suitable for branch circuit, feeder, and equipment protection in electrical distribution systems
Molded case circuit breaker for overcurrent protection in electrical distribution systems. Rated 600 A, 65 kA at 480V AC, with fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Frame size 3
EATON
Molded case circuit breaker for overcurrent protection in electrical distribution systems. Rated 600 A, 65 kA at 480V AC, with fixed instantaneous trip, ABC phase connection, and standard line and load lugs. Frame size 3

More from EATON

View all EATON parts
2-pole molded case circuit breaker rated 40 A with a maximum interrupting rating of 65 kA at 480V AC. Fixed instantaneous trip, AB phase connection, and standard line and load lugs. Frame size 125A/Frame 1. Suitable for overload and short-circuit protection in panelboards, switchboards, and motor control centers
EATON
2-pole molded case circuit breaker rated 40 A with a maximum interrupting rating of 65 kA at 480V AC. Fixed instantaneous trip, AB phase connection, and standard line and load lugs. Frame size 125A/Frame 1. Suitable for overload and short-circuit protection in panelboards, switchboards, and motor control centers
Molded case circuit breaker for overcurrent protection in electrical distribution systems. Rated 35 A, 1-pole, with a 125A/Frame 1 frame size. Fixed instantaneous trip, 65 kA interrupting capacity at 480V AC. Standard line and load lugs for terminal connection
EATON
Molded case circuit breaker for overcurrent protection in electrical distribution systems. Rated 35 A, 1-pole, with a 125A/Frame 1 frame size. Fixed instantaneous trip, 65 kA interrupting capacity at 480V AC. Standard line and load lugs for terminal connection
This 2-pole molded case circuit breaker is rated 50 A with a 125A/Frame 1 frame size. It provides overcurrent protection with a fixed instantaneous trip and a maximum interrupting rating of 65 kA at 480V AC. The AB phase connection and standard line and load lugs facilitate installation in panelboards, switchboards, and motor control centers
EATON
This 2-pole molded case circuit breaker is rated 50 A with a 125A/Frame 1 frame size. It provides overcurrent protection with a fixed instantaneous trip and a maximum interrupting rating of 65 kA at 480V AC. The AB phase connection and standard line and load lugs facilitate installation in panelboards, switchboards, and motor control centers
This 3-pole molded case circuit breaker is rated 35 A with a 125A/Frame 1 frame size. It provides overcurrent protection for branch circuits and feeders in electrical distribution systems, featuring a maximum interrupting rating of 25 kA at 480V AC, fixed instantaneous trip, ABC phase connection, and standard line and load lugs
EATON
This 3-pole molded case circuit breaker is rated 35 A with a 125A/Frame 1 frame size. It provides overcurrent protection for branch circuits and feeders in electrical distribution systems, featuring a maximum interrupting rating of 25 kA at 480V AC, fixed instantaneous trip, ABC phase connection, and standard line and load lugs
Molded case circuit breaker rated 200 A with 225A/Frame 2 frame size. Maximum interrupting rating 65 kA at 240V AC. Fixed instantaneous trip, ABC phase connection, and standard terminals for load-side connection only. Suitable for overcurrent protection in electrical distribution systems
EATON
Molded case circuit breaker rated 200 A with 225A/Frame 2 frame size. Maximum interrupting rating 65 kA at 240V AC. Fixed instantaneous trip, ABC phase connection, and standard terminals for load-side connection only. Suitable for overcurrent protection in electrical distribution systems
Molded case circuit breaker for overcurrent protection in electrical distribution systems. Rated 15 A, 1-pole, with a maximum interrupting rating of 65 kA at 480V AC. Features fixed instantaneous trip and standard line and load lugs. Frame size 125A/Frame 1
EATON
Molded case circuit breaker for overcurrent protection in electrical distribution systems. Rated 15 A, 1-pole, with a maximum interrupting rating of 65 kA at 480V AC. Features fixed instantaneous trip and standard line and load lugs. Frame size 125A/Frame 1
3-pole, 600V AC molded case circuit breaker with 1200A frame size and 50 kA interrupting rating at 480V AC. Features instantaneous trip and ABC phase connection. Used in switchboards, panelboards, and motor control centers for overload and short-circuit protection
EATON
3-pole, 600V AC molded case circuit breaker with 1200A frame size and 50 kA interrupting rating at 480V AC. Features instantaneous trip and ABC phase connection. Used in switchboards, panelboards, and motor control centers for overload and short-circuit protection
Molded case circuit breaker rated 150 A with 25 kA interrupting capacity at 480V AC. Fixed instantaneous trip, ABC phase connection, and standard line/load lugs. Frame size 225A/Frame 2. Suitable for overcurrent protection in electrical distribution systems
EATON
Molded case circuit breaker rated 150 A with 25 kA interrupting capacity at 480V AC. Fixed instantaneous trip, ABC phase connection, and standard line/load lugs. Frame size 225A/Frame 2. Suitable for overcurrent protection in electrical distribution systems