Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Elektrogas NC automatic reset slow opening fast closing - Safety Solenoid Valves
ElektrogasSafety Solenoid Valves

Elektrogas NC automatic reset slow opening fast closing

The Elektrogas VML is a normally-closed safety solenoid valve with automatic reset, slow opening, and fast closing operation, suitable for air, non-aggressive gases (Family 1-2-3, EN 437), with special versions for…

SKU 3G-OTH-02642

Brand
Elektrogas
Item
NC automatic reset slow opening fast closing
Category
Safety Solenoid Valves
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Elektrogas
Gas type
Air and non-aggressive gases (Family 1-2-3, EN 437) / Special version for Biogas/COG / Special version for Hydrogen (H2)
Approvals
CE approved EN 161 / FM approved / EAC approved / Australian Gas Mark
Operating pressure
0 … 200 mbar / 0 … 360 mbar / 0 … 500 mbar / 0 … 6 bar
Material/Connections
AlSi Rp3/8 … Rp2½ / AlSi DN40 … DN80

Datasheet Content

[{"filename":"VML_en.pdf","text":"VML\n VML 60\n\n Safety solenoid valves for gas\n Slow opening and fast closing type\n DN10 … DN80\n\n\n\n\ndelta-elektrogas.com EE162 -0124\n\f ELEKTROGAS – Technical Sheet EE162 - 0124\n\n\n\n\nVML\nVML 60\nSafety solenoid valves for gas\nSlow opening and fast closing type\n\n\nContents\n Description ………………………………………….......... 2\n Features …………………………………………….......... 2\n Functioning and application ………………………......... 3\n Technical specifications ……………………………....... 4\n Gas flow chart (pressure drop) ……………………....... 6\n Ordering information ………………………………......... 8\n Special versions and options …….….….…………....... 8\n Design, installation and servicing ................................ 9\n Standards and approvals …………………………........ 10\n\n\n\n\nDescription The VML type valve is a slow opening single-stage solenoid valve, normally closed (open when\n energized). This type of device is suitable for air or gas blocking and releasing controls, required\n in gas power burners, atmospheric gas boilers, industrial kilns and others gas consuming\n appliances.\n\n\n\n\nFeatures VML valves are made of aluminum alloy die-cast, with a wide range for inlet/outlet connections\n from DN10 (3/8”) up to DN80 (3”).\n Sealings are made of NBR-based rubber certified for use with gas (EN 549).\n Suitable for use with air and non-aggressive gases included in the 1, 2 and 3 families (EN 437).\n Special versions suitable for aggressive gases, free of brass and with FPM seals.\n Pipe connections meet Group 2 and backpressure sealing is compliant with Class A, according\n to EN161 requirements.\n The whole range can be provided in Ex-proof execution, for use in Zones 2 and 22, according to\n 2014/34/EU Directive (ATEX).\n The valve is open only when energized: if, for any reason, power supply goes down, the valve\n closes immediately (intrinsic safe).\n Suitable for heavy-duty cycle operation and qualified for continuous service (100% ED).\n Equipped with max. flow rate and start flow rate adjustment.\n An incorporated fine mesh filter protects the valve seat and disc as well as downstream\n components and prevents dirty contamination (except 6 bar models).\n A proof of closure switch or a visual indicator can be installed (see PCS-VI datasheet for details);\n in this case the valve has to be equipped with 1/8” connection on the bottom. Models from 2”½-\n DN65 and above have this features, smaller models can have it on request.\n Provided with 1/4\" pressure gauge on two sides in the inlet chamber, to connect manometers,\n pressure switches, leakage tester or other gas equipment. Models from 2”½-DN65 and above are\n provided with pressure test points also in the outlet chamber (on request on 1”¼-1”½-2” models).\n The coils are provided with terminal box or with ISO 4400 plug (optional).\n All components are designed to withstand any mechanical, chemical and thermal condition\n occurring during typical service. Effective impregnation and surface treatments have been used\n to improve mechanical sturdiness, sealing and resistance to corrosion of the components.\n Valves are 100% tested by computerized testing machineries and are fully warranted.\n\n\n\n\n 2-11\n\f ELEKTROGAS – Technical Sheet EE162 - 0124\n\n\nFunctioning and\napplication The VML type valve is a safety shutting device using auxiliary power supply.\n When it is de-energized, the spring pushes on the seal disc, keeping the gas passage closed.\n In the inlet chamber there is the gas line pressure which forces on the disc, increasing the closing\n function and improving the seal.\n When the coil is powered, the valve opens slowly because of the hydraulic brake, against the\n strength of the spring and gas pressure. The rapid stroke may be adjusted using the regulating\n screw on the top (see the installation and service instructions), to adjust the initial gas flow. Main\n flow and opening time can be adjusted also.\n If the power supply is shut off, the valve rapidly closes, interrupting the gas flow.\n\n\n\n\n Hydraulic Hydraulic\n brake brake\n\n\n\n\n Fig.1\n\n\n This kind of valve is normally installed as safety and regulating device in gas trains, for industrial\n applications and gas firing systems.\n Figure 2 shows an example of installation with other Elektrogas devices.\n\n 1 = Ball valve VSG\n 2 = Filter FG\n 3 = Pressure regulator R\n 4 = Tightness control LD\n 5 = Gas pressure switch PSG\n 6 = Valve position visual indicator VI\n 7 = Fast opening solenoid valve VMR\n 8 = Slow opening solenoid valve VML\n 9 = Tightness control pressure switch\n 10 = Valve position electrical indicator PCS\n 11 = Pressure gauge MG\n 12 = Push button valve ME\n\n\n\n\n Fig.2\n\n 3-11\n\f ELEKTROGAS – Technical Sheet EE162 - 0124\n\n\nTechnical\nspecifications Tab. 1\n Connections Internal threaded EN 10226-1 from Rp3/8 to Rp2½ or\n ANSI-ASME B1.20 from 3/8”NPT to 2”½NPT\n Flanged ISO 7005 PN16 from DN40 to DN80 or\n ANSI- ASA- ASME B16.5 class 150 from 2” to 3”\n Voltage ratings 230 VAC 50/60 Hz\n 120 VAC 50/60 Hz\n 110 VAC 50/60 Hz\n 24 VAC/DC\n Voltage tolerance -15% to +10%\n Ambient temperature -15°C to +60°C (+5°F to +140°F)\n Media temperature\n Max. operating pressure 200 mbar (3 psig)\n 360 mbar (5 psig)\n 500 mbar (7 psig)\n 6 bar * (90 psig)\n Max test pressure 1 bar (15 psig)\n 9 bar * (130 psig)\n Closing time < 1 second\n Opening time Adjustable\n Gas strainer 600 µm (0,02 in), metal mesh\n (except 6bar versions)\n Enclosure IP54 (NEMA 3)\n optional IP65 with cable (NEMA 4)\n Cable gland M20x1,5 for terminal box\n PG 9 for ISO plug\n Wires cross-section 2,5 mm2 max. (AWG 12) for terminal board\n 1,5 mm2 max. (AWG 14) for ISO plug\n Electrical safety Class I (EN 60335-1)\n Coil winding insulation Class H (200°C, 392°F)\n Coil thermal resistance Class F (155°C, 311°F)\n Materials in contact with gas Aluminum alloy, Brass, Stainless steel, Plated steel\n Anaerobic adhesive, Nitrile rubber (NBR), Fluoroelastomer\n (FPM), Polytetrafluoroethylene (PTFE)\n\n (*) Operating pressure lower than 200mbar (3psig) not advisable\n\n Tab. 2\nPower 200 mbar 360 mbar 500 mbar 6 bar\nConsumption (3 psig) (5 psig) (7 psig) (90 psig)\n[W] 230V 120V 110V 24V 12V 230V 120V 110V 24V 12V 230V 120V 110V 24V…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Elektrogas Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Elektrogas VML is a normally-closed safety solenoid valve with automatic reset, slow opening, and fast closing operation, suitable for air, non-aggressive gases (Family 1-2-3, EN 437), with special versions for biogas/COG and hydrogen. It is available with CE, FM, EAC, and Australian Gas Mark approvals, in operating pressure ranges of 0…200 mbar, 0…360 mbar, 0…500 mbar, and 0…6 bar, and with AlSi connections from Rp3/8 to Rp2½ or DN40 to DN80.

Frequently Asked Questions

What is the Elektrogas VML safety solenoid valve used for?

The Elektrogas VML is a normally closed safety solenoid valve used for gas and air blocking and adjusting controls in atmospheric burners, fan-assisted burners, industrial kilns, and other gas equipment. It features slow opening with adjustable speed and rapid closing when de-energized, suitable for continuous service (100% ED).

What are the specifications of the Elektrogas VML valve?

The VML valve handles air and non-aggressive gases (Families 1-2-3, EN 437) with operating pressures up to 6 bar. Connections range from Rp3/8 to Rp2½ (AlSi) and DN40 to DN80. It is CE approved per EN 161, FM approved, EAC approved, and carries the Australian Gas Mark. Special versions are available for biogas and hydrogen.

Where to buy the Elektrogas VML valve in Singapore?

3G Electric supplies the Elektrogas VML safety solenoid valve to Singapore. We handle sourcing, logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on this model. We provide technical support for selection and application in local industrial burner and kiln systems.

How to install and maintain the Elektrogas VML valve?

Install the VML valve with the flow direction arrow aligned and ensure upstream gas filtration. The valve has an incorporated fine mesh filter (except 6 bar models) to protect internal components. For maintenance, periodically check sealings and clean the filter. Always de-energize and isolate gas supply before servicing. Refer to the Elektrogas datasheet for torque and wiring details.

Used in

Common applications for Elektrogas
Industrial steam and hot-water boiler gas trains — VMR slow-opening solenoid valves on modulating burners
Commercial kitchen and bakery gas-fired ovens — VML magnetic valves for appliance-level safety shut-off
Process-industry gas supply skids — VMH high-pressure variants rated to 6 bar for elevated-pressure networks
Burner OEM gas-train assemblies — multibloc combined-function units reducing commissioning and leak paths
Retrofit drop-in replacements for existing Elektrogas VMR valves on installed burner racks

Elektrogas Products

3G Electric supplies Elektrogas safety solenoid valves. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
NC automatic reset slow opening fast closing. The VMH-type valve is a shut-off valve for gaseous media operated by a hydraulic actuator. It is suitable as main safety device for gas blocking and gas releasing controls, as required when operating gas burners, atmospheric gas boilers, industrial kilns, and generally all gas-consuming appliances. When the actuator gets energized, it slowly opens the valve over a few seconds. Once fully open, the hydraulic pump turns off to minimize power consumption. As soon as the power supply stops, the valve closes immediately (<1 sec). It is qualified for continuous service (100% ED)
Elektrogas
NC automatic reset slow opening fast closing. The VMH-type valve is a shut-off valve for gaseous media operated by a hydraulic actuator. It is suitable as main safety device for gas blocking and gas releasing controls, as required when operating gas burners, atmospheric gas boilers, industrial kilns, and generally all gas-consuming appliances. When the actuator gets energized, it slowly opens the valve over a few seconds. Once fully open, the hydraulic pump turns off to minimize power consumption. As soon as the power supply stops, the valve closes immediately (<1 sec). It is qualified for continuous service (100% ED)
NC solenoid valve for air control fast/slow opening fast/slow closing. The VRA – VLA – VTA types are normally closed solenoid valves for regulation of cold combustion air. When the coil is unenergized, the spring pushes on the disk to keep the adjusted minimum air passage. The valve opens when the coil is powered, moving the disc to the maximum open position. The valve moves to the minimum position when the power is off. This type of device is suitable for high/low stage control of combustion air in industrial gas burners. (qualified for continuous service- 100% ED)
Elektrogas
NC solenoid valve for air control fast/slow opening fast/slow closing. The VRA – VLA – VTA types are normally closed solenoid valves for regulation of cold combustion air. When the coil is unenergized, the spring pushes on the disk to keep the adjusted minimum air passage. The valve opens when the coil is powered, moving the disc to the maximum open position. The valve moves to the minimum position when the power is off. This type of device is suitable for high/low stage control of combustion air in industrial gas burners. (qualified for continuous service- 100% ED)
Solenoid valve VML1 tapped D1/2" 500 Mbar
Elektrogas
Solenoid valve VML1 tapped D1/2" 500 Mbar
Elektrogas
Elektrogas
Solenoid valve VML2 threaded D3/4" 500 Mbar
Automatic solenoid actuators for control valves fast/slow opening fast/slow closing. Solenoid actuators operate VF, VFR and VFH butterfly valves. When the coil is unenergized, the inner spring pushes down the plunger and uses gear mating to shift the connected valve to the minimum opening position. When energized, the coil moves the plunger up quickly (SR) or slowly (SL-ST), shifting the valve to the maximum opening position. This device, connected to VF, VFR and VFH butterfly valves, is used in two-stage control of gas and air in combustion processes
Elektrogas
Automatic solenoid actuators for control valves fast/slow opening fast/slow closing. Solenoid actuators operate VF, VFR and VFH butterfly valves. When the coil is unenergized, the inner spring pushes down the plunger and uses gear mating to shift the connected valve to the minimum opening position. When energized, the coil moves the plunger up quickly (SR) or slowly (SL-ST), shifting the valve to the maximum opening position. This device, connected to VF, VFR and VFH butterfly valves, is used in two-stage control of gas and air in combustion processes
Elektrogas
Elektrogas
Solenoid valve VML3 tapped D1" 500 Mbar

More from Elektrogas

View all Elektrogas parts
NC/NO manual reset safety valve for gas fast closing. The EVRM-NA –NC type valve is a manual reset safety valve for gas. A manual operation is necessary to open the valve while shut off is completely automatic and operated by solenoid. This type of device, connected with one or more leakage detectors or alarm signals for the presence of carbon monoxide or any other type of alarm system that can operate a power supply, is suitable for performing locking operations on the gas line
Elektrogas
NC/NO manual reset safety valve for gas fast closing. The EVRM-NA –NC type valve is a manual reset safety valve for gas. A manual operation is necessary to open the valve while shut off is completely automatic and operated by solenoid. This type of device, connected with one or more leakage detectors or alarm signals for the presence of carbon monoxide or any other type of alarm system that can operate a power supply, is suitable for performing locking operations on the gas line
NC automatic reset multiple valve. The VMM-type valve houses two solenoid valves in one body. The first safety valve is fast-opening, and the second is fast or slow. An optional third valve, fast or slow opening, can be connected to the side, with function of bypass or pilot valve. VMM is suitable for gas or air-blocking, two stage operation, adjusting controls in atmospheric or fan-assisted burners, industrial kilns, and all gas equipment that uses regulating trains
Elektrogas
NC automatic reset multiple valve. The VMM-type valve houses two solenoid valves in one body. The first safety valve is fast-opening, and the second is fast or slow. An optional third valve, fast or slow opening, can be connected to the side, with function of bypass or pilot valve. VMM is suitable for gas or air-blocking, two stage operation, adjusting controls in atmospheric or fan-assisted burners, industrial kilns, and all gas equipment that uses regulating trains
NO automatic reset vent valve fast opening fast closing. VMRNA type is an automatic vent valve for gas appliances. It is suitable for discharging gas excess or gas leakage into relief lines. VMRNA valve is a reverse acting solenoid valve: when deenergized, the valve is open (N.O. normally open). VMRNA valve can be integrated in Elektrogas VMM multiple valve to obtain a very compact system
Elektrogas
NO automatic reset vent valve fast opening fast closing. VMRNA type is an automatic vent valve for gas appliances. It is suitable for discharging gas excess or gas leakage into relief lines. VMRNA valve is a reverse acting solenoid valve: when deenergized, the valve is open (N.O. normally open). VMRNA valve can be integrated in Elektrogas VMM multiple valve to obtain a very compact system
NC automatic reset fast opening fast closing. The VMR-type valve is a normally closed solenoid valve that is fast-opening. When the coil is unenergized, the spring pushes on the disc to keep the gas passage closed. When the coil is powered, the valve opens. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, industrial kilns, and all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
Elektrogas
NC automatic reset fast opening fast closing. The VMR-type valve is a normally closed solenoid valve that is fast-opening. When the coil is unenergized, the spring pushes on the disc to keep the gas passage closed. When the coil is powered, the valve opens. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, industrial kilns, and all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)