Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Elektrogas NC solenoid valve for air control fast/slow opening fast/slow closing - Air Solenoid valves
ElektrogasAir Solenoid valves

Elektrogas NC solenoid valve for air control fast/slow opening fast/slow closing

Elektrogas presents the NC solenoid valve for air control fast/slow opening fast/slow closing, an air solenoid valve offering High/Low stage operation. Available in VRA, VLA, and VTA models, the VRA provides 1-second…

SKU 3G-OTH-02651

Also listed as: VRAVLAVTA · VRA VLA VTA · VRA-VLA-VTA

Brand
Elektrogas
Item
NC solenoid valve for air control fast/slow opening fast/slow closing
Category
Air Solenoid valves
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Elektrogas
Setting
High/Low stage operation / VRA: 1s opening/closing / VLA: ~4s opening/1s closing / VTA: ~4s opening/closing / Bypass bore (optional)
Media Temperature
Cold air 60°C max
Operating Pressure
0 … 200 mbar
Material/Connections
AlSi Rp3/8 … Rp2½ / AlSi DN40 … DN80

Datasheet Content

[{"filename":"VRA-VLA-VTA_en.pdf","text":"VRA\n VLA\n VTA\n\n Solenoid valves for\n combustion Air regulation\n DN10 … DN80\n\n\n\n\ndelta-elektrogas.com EE164 -0124\n\f ELEKTROGAS – Technical Sheet EE164 - 0124\n\n\n\n\nVRA\nVLA\nVTA\nSolenoid valves for\ncombustion Air regulation\n\nContents\n Description ………………………………………….. 2\n Features …………………………………………….. 2\n Functioning and application ………………………. 3\n Technical specifications …………………………… 4\n Air flow chart (pressure drop) …………………..… 6\n Ordering information …………………………….…. 8\n Special versions and options ....………….……….. 8\n Design, installation and servicing ….......…………. 9\n Standards and approvals ……………………….…. 10\n\n\n\nDescription The VRA/VLA/VTA types are normally closed solenoid valves for cold combustion air regulation\n (open when energized). This type of device is suitable for high/low control of combustion air in\n industrial gas burners.\n\n\n\n\nFeatures The valves are made of aluminum alloy die-cast, with a wide range for inlet/outlet connections\n from DN 10 (3/8”) up to DN 80 (3”).\n Pipe connections meet group 2, according to EN161 requirements.\n Suitable for use with cold combustion air (not for safety shut-off).\n Provided with two flow adjustments: minimum and maximum flow rate, for high/low operation.\n Suitable for heavy-duty cycle operation and for continuous service (100% ED).\n The whole range can be provided in Ex-proof execution, for use in Zones 2 and 22, according to\n 2014/34/EU Directive (ATEX).\n The valve is supplied without an internal filter, because in many applications the air is very dirty\n and it should clog the filter in short time. It is provided with a special dust cover able to protect\n mechanical moving parts.\n Provided with 1/4” pressure gauge on two sides in the inlet chamber, to connect manometers,\n pressure switches or other equipment. Models from 2”½-DN65 and above are provided with\n pressure test points also in the outlet chamber. Models 1”¼-1”½-2” can be provided on request.\n The coils are provided with terminal box or with ISO 4400 plug (optional).\n All components are designed to withstand any mechanical, chemical and thermal condition\n occurring during typical service. Effective impregnation and surface treatments have been used\n to improve mechanical sturdiness, sealing and resistance to corrosion of the components.\n Valves are 100% tested by computerized testing machineries and are fully warranted.\n\n\n\n\n 2-10\n\f ELEKTROGAS – Technical Sheet EE164 - 0124\n\n\nFunctioning and\napplication The VRA type valve is a fast opening/closing solenoid valve. The VLA type is a slow opening and\n fast closing solenoid valve. The VTA type is a slow opening/closing solenoid valve.\n Both Min./Max. can be set from 0 to100%.\n When not energized the spring works on the disc keeping the minimum passage of air. When\n powering the coil the valve opens, moving the disc to the maximum open position. When power\n is switched off the valve moves to the minimum position.\n\n\n\n\n Min. Flow Max. Flow\n\n\n Fig.1\n\n\n Figure 2 shows an example of installation.\n\n\n\n\n1 = Ball valve\n2 = Filter\n3 = Fast opening solenoid valve for gas\n4 = Slow opening solenoid valve for gas\n5 = Air/gas ratio regulator\n6 = Stainless steel bellow\n7 = Burner\n8 = Adjusting cock\n9 = Slow opening solenoid valve for air\n\n\n\n\n Fig.2\n\n\n\n\n 3-10\n\f ELEKTROGAS – Technical Sheet EE164 - 0124\n\n\nTechnical\nspecifications Tab. 1\n Connections Gas threaded EN 10226-1 from Rp3/8 to Rp2½ or\n ANSI-ASME B1.20 from 3/8”NPT to 2”½NPT\n Flanged PN16 – ISO 7005 from DN40 to DN80 or\n ANSI-ASA-ASME B16.5 class 150 from 2” to 3”\n\n Voltage rating 230 VAC 50/60 Hz\n 120 VAC 50/60 Hz\n 110 VAC 50/60 Hz\n 24 VAC/DC\n 12 VAC/DC\n\n Voltage tolerance -15% / +10%\n\n Ambient temperature -15°C to +60°C (+5°F to +140°F)\n Media temperature\n\n Max. operating pressure 200 mbar (3 psig)\n\n Max test pressure 1 bar (15 psig)\n\n Operating time VRA: 1s opening/closing\n VLA: ~4s opening / 1s closing\n VTA: ~4s opening/closing\n\n Gas strainer None\n\n Enclosure IP54 (NEMA 3)\n optional IP65 with cable (NEMA 4)\n\n Cable gland M20x1,5 for terminal box\n PG 9 for ISO plug\n\n Wires cross-section 2,5 mm2 max. (AWG 12) for terminal board\n 1,5 mm2 max. (AWG 14) for ISO plug\n Electrical safety Class I (EN 60335-1)\n\n Coil winding insulation Class H (200°C, 392°F)\n\n Coil thermal resistance Class F (155°C, 311°F)\n\n\n\n\n Tab. 2\n Power 200 mbar\n Consumption (3 psig)\n [W] 230V 120V 110V 24V 12V\n O 20 20 20 20 20\n 3/8”-1/2”\n H 20 20 20 20 20\n O 25 30 30 30 30\n 3/4”-1”\n H 25 30 30 30 30\n O 180 180 180 65 65\n 1”¼-1”½-2”\n H 45 45 45 65 65\n O 180 180 180 - -\n 2”½-3”\n H 45 45 45 - -\n O – opening power consumption\n H – holding power consumption\n\n\n\n\n 4-10\n\f ELEKTROGAS – Technical Sheet EE164 - 0124\n\n\n\n\n Fig.3\n\n\n Tab. 3\n Connections Overall dimensions (3) Weight (2)\n [mm]\n [in] [Kg]\n A B C D E Int h [lbs]\n Rp 3/8 88 96 145 153 54 - - 1,4 / 1,6\n 3/8”NPT 3,46 3,78 5,71 6,03 2,13 3,1 / 3,6\n Rp 1/2 88 96 145 153 54 - - 1,4 / 1,6\n 1/2”NPT 3,46 3,78 5,71 6,03 2,13 3,1 / 3,6\n Rp 3/4 88 96 145 179 54 - - 2,5 / 2,7\n 3/4”NPT 3,46 3,78 5,71 7,05 2,13 5,5 / 6,0\n Rp 1 88 96 145 179 54 - - 2,5 / 2,7\n 1”NPT 3,46 3,78 5,71 7,05 2,13 5,5 / 6,0\n Rp 11/4 120 153 191 235 70 - - 5,7 / 6,2\n 1”¼NPT 4,72 6,02 7,52 9,25 2,76 12,6 / 13,7\n Rp 11/2 120 153 191 235 70 - - 5,7 / 6,2\n 1”½NPT 4,72 6,02 7,52 9,25 2,76 12,6 / 13,7\n Rp 2 106 156 195 245 70 - - 6,0 / 6,5\n 2”NPT 4,17 6,14 7,68 9,65 2,76 13,2 / 14,3\n Rp 2½ 180 218 254 315 70 - - 11,6 / 12,1\n 2”½NPT 7,09 8,58 10,00 12,40 2,76 25,6 / 26,7\n DN 40 165 196 195 271 70 110 4x18 7,4 / 7,9\n - - - - - - - -\n DN 50 165 196 195 271 70 125 4x18 7,4 / 7,9\n 2\"ANSI (1) 6,50 7,72 7,68 10,94 2,76 4,75 4x¾ 16,3 / 17,4\n DN 65 200 305 266 355 70 145 4x18 14,0 / 14,5\n 2\"½ANSI 7,87 12,01 10,47 13,98 2,76 5,50 4x¾ 30,9 / 32,0\n DN 80 200 305 266 355 70 160 8x18 14,0 / 14,5\n 3\"ANSI 7,87 12,01 10,47 13,98 2,76 6,00 4x¾ 30,9 / 32,0\n1\n( ) Optional Kit (2) VRA / VLA (3) VTA type: E+10 mm\n\n\n\n\n 5-10\n\f ELEKTROGAS – Technical Sheet EE164 - 0124\n\n\n\n\nAir flow chart\n(Pressure drop)\n\n\n\n dP inch\n\n 0.04\n 0.05\n 0.1 0.2 0.3 0.4\n 0.5\n 1.0\n 0.06\n 20 40\n…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Elektrogas Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Elektrogas presents the NC solenoid valve for air control fast/slow opening fast/slow closing, an air solenoid valve offering High/Low stage operation. Available in VRA, VLA, and VTA models, the VRA provides 1-second opening and closing, the VLA approximately 4-second opening and 1-second closing, and the VTA approximately 4-second opening and closing, with an optional bypass bore. This valve handles cold air media up to 60°C, operates at 0 to 200 mbar pressure, and features AlSi connections in Rp3/8 to Rp2½ or DN40 to DN80 sizes.

Frequently Asked Questions

What is the Elektrogas VRA VLA VTA air solenoid valve used for?

The Elektrogas VRA, VLA, and VTA are normally closed solenoid valves for regulating cold combustion air in industrial gas burners. They enable high/low stage control, adjusting airflow between minimum and maximum positions for efficient burner operation. These valves are suitable for continuous service (100% ED) and heavy-duty cycles.

What are the specifications of the Elektrogas VRA VLA VTA valve?

The Elektrogas VRA/VLA/VTA valves handle cold air up to 60°C max, with operating pressure from 0 to 200 mbar. Connections range from Rp3/8 to Rp2½ (AlSi) or DN40 to DN80. VRA offers ~1s opening/closing, VLA ~4s opening/1s closing, and VTA ~4s opening/closing. An optional bypass bore is available.

Where to buy Elektrogas VRA VLA VTA valves in Singapore?

3G Electric supplies Elektrogas VRA, VLA, and VTA air solenoid valves to Singapore. We handle logistics, customs clearance, and delivery for your order. Contact us for pricing and lead time on these valves. We source and deliver genuine Elektrogas components for industrial burner applications.

How to install and maintain the Elektrogas VRA VLA VTA valve?

Install the Elektrogas valve with the flow direction arrow aligned correctly. Ensure the air is filtered upstream to protect moving parts, as the valve is supplied without an internal filter. For maintenance, periodically check the dust cover and pressure gauge connections. Refer to the manufacturer's datasheet for specific torque and wiring details.

Used in

Common applications for Elektrogas
Industrial steam and hot-water boiler gas trains — VMR slow-opening solenoid valves on modulating burners
Commercial kitchen and bakery gas-fired ovens — VML magnetic valves for appliance-level safety shut-off
Process-industry gas supply skids — VMH high-pressure variants rated to 6 bar for elevated-pressure networks
Burner OEM gas-train assemblies — multibloc combined-function units reducing commissioning and leak paths
Retrofit drop-in replacements for existing Elektrogas VMR valves on installed burner racks

Elektrogas Products

3G Electric supplies Elektrogas air solenoid valves. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
NC automatic reset fast opening fast closing. The VMR-type valve is a normally closed solenoid valve that is fast-opening. When the coil is unenergized, the spring pushes on the disc to keep the gas passage closed. When the coil is powered, the valve opens. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, industrial kilns, and all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
Elektrogas
NC automatic reset fast opening fast closing. The VMR-type valve is a normally closed solenoid valve that is fast-opening. When the coil is unenergized, the spring pushes on the disc to keep the gas passage closed. When the coil is powered, the valve opens. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, industrial kilns, and all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
NC automatic reset slow opening fast closing. The VML-type valve is a normally closed safety valve with slow opening and adjustable rapid stroke for initial gas flow. When not in the working position, the spring pushes on the disc, keeping the gas passage closed. When the coil is powered, the valve opens slowly, with adjustable speed. If an initial rapid stroke is set, valve opens rapidly in the first section. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, in industrial kilns, and in all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
Elektrogas
NC automatic reset slow opening fast closing. The VML-type valve is a normally closed safety valve with slow opening and adjustable rapid stroke for initial gas flow. When not in the working position, the spring pushes on the disc, keeping the gas passage closed. When the coil is powered, the valve opens slowly, with adjustable speed. If an initial rapid stroke is set, valve opens rapidly in the first section. The valve rapidly shuts when the power is off. This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fan-assisted burners, in industrial kilns, and in all gas equipment that uses gas solenoid valves (qualified for continuous service – 100% ED)
Automatic solenoid actuators for control valves fast/slow opening fast/slow closing. Solenoid actuators operate VF, VFR and VFH butterfly valves. When the coil is unenergized, the inner spring pushes down the plunger and uses gear mating to shift the connected valve to the minimum opening position. When energized, the coil moves the plunger up quickly (SR) or slowly (SL-ST), shifting the valve to the maximum opening position. This device, connected to VF, VFR and VFH butterfly valves, is used in two-stage control of gas and air in combustion processes
Elektrogas
Automatic solenoid actuators for control valves fast/slow opening fast/slow closing. Solenoid actuators operate VF, VFR and VFH butterfly valves. When the coil is unenergized, the inner spring pushes down the plunger and uses gear mating to shift the connected valve to the minimum opening position. When energized, the coil moves the plunger up quickly (SR) or slowly (SL-ST), shifting the valve to the maximum opening position. This device, connected to VF, VFR and VFH butterfly valves, is used in two-stage control of gas and air in combustion processes
NC automatic reset multiple valve. The VMM-type valve houses two solenoid valves in one body. The first safety valve is fast-opening, and the second is fast or slow. An optional third valve, fast or slow opening, can be connected to the side, with function of bypass or pilot valve. VMM is suitable for gas or air-blocking, two stage operation, adjusting controls in atmospheric or fan-assisted burners, industrial kilns, and all gas equipment that uses regulating trains
Elektrogas
NC automatic reset multiple valve. The VMM-type valve houses two solenoid valves in one body. The first safety valve is fast-opening, and the second is fast or slow. An optional third valve, fast or slow opening, can be connected to the side, with function of bypass or pilot valve. VMM is suitable for gas or air-blocking, two stage operation, adjusting controls in atmospheric or fan-assisted burners, industrial kilns, and all gas equipment that uses regulating trains
NO automatic reset vent valve fast opening fast closing. VMRNA type is an automatic vent valve for gas appliances. It is suitable for discharging gas excess or gas leakage into relief lines. VMRNA valve is a reverse acting solenoid valve: when deenergized, the valve is open (N.O. normally open). VMRNA valve can be integrated in Elektrogas VMM multiple valve to obtain a very compact system
Elektrogas
NO automatic reset vent valve fast opening fast closing. VMRNA type is an automatic vent valve for gas appliances. It is suitable for discharging gas excess or gas leakage into relief lines. VMRNA valve is a reverse acting solenoid valve: when deenergized, the valve is open (N.O. normally open). VMRNA valve can be integrated in Elektrogas VMM multiple valve to obtain a very compact system
NC/NO manual reset safety valve for gas fast closing. The EVRM-NA –NC type valve is a manual reset safety valve for gas. A manual operation is necessary to open the valve while shut off is completely automatic and operated by solenoid. This type of device, connected with one or more leakage detectors or alarm signals for the presence of carbon monoxide or any other type of alarm system that can operate a power supply, is suitable for performing locking operations on the gas line
Elektrogas
NC/NO manual reset safety valve for gas fast closing. The EVRM-NA –NC type valve is a manual reset safety valve for gas. A manual operation is necessary to open the valve while shut off is completely automatic and operated by solenoid. This type of device, connected with one or more leakage detectors or alarm signals for the presence of carbon monoxide or any other type of alarm system that can operate a power supply, is suitable for performing locking operations on the gas line

More from Elektrogas

View all Elektrogas parts