The FIELD CONTROLS Power Venter is a pipe-mount exhaust draft inducer for LP-fueled furnaces, compatible with Tjernlund and replacing model HS1. It operates on 115V AC, 60 Hz, draws 2.1 A, and includes a 4 in vent…

SKU 3G-OTH-74824

Also listed as: PVG100 · PVG 100

Brand
FIELD CONTROLS
Item
Power Venter PVG-100
Part Number
PVG-100
Category
Pipe-Mount Exhaust Draft Inducers
Available to Order
Also known as:PVG-100FIELD CONTROLS
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

FIELD CONTROLS
Manufacturer Part Number
PVG-100
Type
For 3 in to 4 in Pipe, 0.245 cfm @ 0.0 in SP, Steel Wheel
AC
115V
Ph
1
Current
2.1 A
Includes
4 in Vent Hood
Frequency
60 Hz
Standards
cETLus Listed
Application
Furnaces
For Fuel Type
LP
Wheel Material
Steel
Nominal Voltage
115V AC
Nameplate Voltage
115V AC
Compatible with Brand
Tjernlund
Replacement For Manufacturer Model Number
HS1

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FIELD CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FIELD CONTROLS Power Venter is a pipe-mount exhaust draft inducer for LP-fueled furnaces, compatible with Tjernlund and replacing model HS1. It operates on 115V AC, 60 Hz, draws 2.1 A, and includes a 4 in vent hood. The unit features a steel wheel and is cETLus Listed.

Frequently Asked Questions

What is the FIELD CONTROLS Power Venter PVG-100 used for?

The FIELD CONTROLS Power Venter PVG-100 is a pipe-mount exhaust draft inducer designed for LP-fueled furnaces. It helps ensure proper venting by creating a controlled draft, improving combustion efficiency and safety in residential and light commercial heating systems.

What are the specifications of the FIELD CONTROLS Power Venter PVG-100?

The PVG-100 operates on 115V AC, 60 Hz, draws 2.1 A, and includes a 4 in vent hood. It features a steel wheel, delivers 0.245 cfm at 0.0 in SP, and is cETLus Listed. It replaces model HS1 and is compatible with Tjernlund systems.

Where to buy the FIELD CONTROLS Power Venter PVG-100 worldwide?

3G Electric supplies the FIELD CONTROLS Power Venter PVG-100 worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the FIELD CONTROLS Power Venter PVG-100?

Install the PVG-100 on the furnace vent pipe per local codes. Mount it securely, connect 115V AC power, and verify the steel wheel rotates freely. Ensure the 4 in vent hood is properly attached. Always follow the manufacturer's instructions and consult a qualified technician.

Used in

Common applications for FIELD CONTROLS
Oil-fired furnaces — Field Controls Power Venter pipe-mount draft inducer (SKU 45DX30) for 3 in to 4 in pipe, 115V AC, 1.7 A.
Natural gas furnaces — Field Controls Power Venter pipe-mount draft inducer (SKU 45DX25) for 4 in to 5 in pipe, 115V AC, 1.3 A.
LP-fueled furnaces — Field Controls Power Venter pipe-mount draft inducer (SKU 45DX27) for 5 in to 6 in pipe, 115V AC, 2.1 A.
Oil-fired boilers and water heaters — Field Controls DI-1 pipe-mount draft inducer (SKU 45DX35) with pressure sensing tube, 115V AC, 0.43 A.
Residential ventilation — Field Controls energy-recovery ventilator (FC-150EC-ERV) with fixed plate core, 145 cfm, 84% efficiency.
HVAC control systems — Field Controls FCMC fresh air ventilation control with SPDT switch, 24V AC, temperature sensing from -20°F to 150°F.
Not sure this is the right part? Photo-identify it→

FIELD CONTROLS Products

3G Electric supplies FIELD CONTROLS pipe-mount exhaust draft inducers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from FIELD CONTROLS

View all FIELD CONTROLS parts →
Pipe-mount exhaust draft inducer for natural-gas furnaces, designed for 4 in to 4 in pipe. Operates on 115V AC, 60 Hz, single phase, 2.1 A, with a steel wheel. Delivers 0.691 cfm at 0.0 in SP. Includes a 4 in MG-1 Draft Control. cETLus Listed
FIELD CONTROLS
Pipe-mount exhaust draft inducer for natural-gas furnaces, designed for 4 in to 4 in pipe. Operates on 115V AC, 60 Hz, single phase, 2.1 A, with a steel wheel. Delivers 0.691 cfm at 0.0 in SP. Includes a 4 in MG-1 Draft Control. cETLus Listed
Pipe-mount exhaust draft inducer for natural gas furnaces, designed to improve exhaust flow in vent systems. Fits 8 in to 12 in pipe, delivers 1.86 cfm at 0.0 in SP. Includes pressure sensing tube, steel wheel, operates at 115V AC, 3.9 A, 60 Hz. cETLus Listed
FIELD CONTROLS
Pipe-mount exhaust draft inducer for natural gas furnaces, designed to improve exhaust flow in vent systems. Fits 8 in to 12 in pipe, delivers 1.86 cfm at 0.0 in SP. Includes pressure sensing tube, steel wheel, operates at 115V AC, 3.9 A, 60 Hz. cETLus Listed
Pipe-mount exhaust draft inducer for oil-fired furnaces. Operates on 115V AC at 60 Hz, draws 1.1 A, delivers 0.786 cfm at 0.0 in SP. Includes pressure sensing tube and steel wheel. cETLus Listed. Fits 5 in to 8 in pipe
FIELD CONTROLS
Pipe-mount exhaust draft inducer for oil-fired furnaces. Operates on 115V AC at 60 Hz, draws 1.1 A, delivers 0.786 cfm at 0.0 in SP. Includes pressure sensing tube and steel wheel. cETLus Listed. Fits 5 in to 8 in pipe