Fireye Flame-3G-OTH-02815 Amplifier Modules are programmer and amplifier modules available in models E1R1, EUV1, ERT1, and EUVS4. These cULus and FM Approved modules offer direct coupling with Insight and Phoenix…

SKU 3G-OTH-02815

Brand
Fireye
Item
Flame-Monitor Amplifier Modules. The Fireye E1R1, EUV1, ERT1
Category
Programmer & Amplifier Modules
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Fireye
Models
E1R1, EUV1, ERT1, EUVS4
Category
Programmer & Amplifier Modules
Approvals
cULus, FM Approved
Description
Another option for direct coupling with Insight and Phoenix scanners, providing efficient flame monitoring.
Compatible Scanners
Insight, Phoenix
EUV1 Standard UV Amplifier
Compatible Scanners: UV1A, UV8A, 45UV3, UV90 Description: Standard amplifier module for ultraviolet scanners, ensuring precise flame detection and reliable performance.
ERT1 Rectification Amplifier
Compatible Scanners: 69ND1 Description: Provides rectification and amplification for flame detection systems, suitable for a range of ultraviolet scanners.
EDC1 Direct Coupled Amplifier
Compatible Scanners: Insight, Phoenix Description: Offers direct coupling with Insight and Phoenix scanners for seamless integration and performance.
EDC2 Direct Coupled Amplifier
Compatible Scanners: Insight, Phoenix Description: Another option for direct coupling with Insight and Phoenix scanners, providing efficient flame monitoring.
EUVS4 Self-Check UV Amplifier
Compatible Scanners: 45UV5-1007/1008/1009 Description: Features self-check capabilities for ultraviolet scanners, enhancing system reliability and accuracy.
E1R1 AutoCheck Infrared Amplifier
Compatible Scanners: 48PT2 Description: Designed for use with AutoCheck infrared scanners, providing reliable flame detection and monitoring.
E1R2 AutoCheck Infrared Amplifier
Compatible Scanners: 48PT2 Description: Specially designed for unique applications. For specific requirements, consult the factory for details.
E1R3 AutoCheck Infrared Amplifier
Compatible Scanners: 48PT2 Description: Another option for use with AutoCheck infrared scanners, offering robust flame scanning capabilities.

Datasheet Content

[{"filename":"EAMP1-Flame_Monitor_Amplifier_Modules_E1R1_EUV1_ERT1_EUVS4_EDC1_EDC2_English_2014-04-03.pdf","text":"\n\n EAMP1\n APRIL 3, 2013\n\n ®\n FIREYE\n E1R1, EUV1, ERT1,\n EUVS4, EDC1 and EDC2\n Flame Amplifier Modules\n FOR USE WITH THE\n FLAME-3G-OTH-02815™ CONTROL\n (For use with the Phoenix Scanners see 133-732)\n\n\n APPROVED\n\n\n\n\nDESCRIPTION\n The FIREYE E1R1, EUV1, ERT1 and EUVS4 Amplifier Modules are used in conjunction with the\n FIREYE FLAME-3G-OTH-02815 system. These modules provide flame scanning using any of the FIR-\n EYE AutoCheck infrared scanners, standard ultraviolet scanners, flame rod, and ultraviolet self-\n check scanners. After scanner selection the proper amplifier module must be inserted in the Flame-\n 3G-OTH-02815 chassis.\n Refer to Fireye Bulletin E-1101 for more detailed information concerning the FIREYE\n FLAME-3G-OTH-02815 system and operation. Also, follow the scanner installation and wiring\n suggestions found in E-1101 for proper flame scanning operation.\n\n\nAPPROVALS\n Underwriters Laboratories Inc.:\n MCCZ File MP 1537\n Controls, Primary Safety - Listed\n MCCZ2 File MP1537\n Controls, Primary Safety - Component\n MCCZ7 File MP1537\n Controls, Primary Safety Certified for Canada\n MCCZ8 file MP1537\n Controls, Primary Safety Certified for Canada - Component\n Acceptable by: Industrial Risk Insurers (I.R.I.)\n Factory Mutual Approved\n\n 1\n\f \n\n\n\n\nFLAME AMPLIFIER SELECTION\n FIREYE PART NUMBER DESCRIPTION USE WITH SCANNER\n\n EUV1 STANDARD UV AMPLIFIER UV1A, UV8A, 45UV3, UV90\n\n E1R1 * AUTOCHECK INFRARED AMPLIFIER 48PT2\n\n E1R2 AUTOCHECK INFRARED AMPLIFIER 48PT2\n (FOR SPECIAL APPLICATIONS\n ONLY) CONSULT FACTORY\n\n ERT1 RECTIFICATION AMPLIFIER 69ND1\n\n EUVS4 SELF-CHECK UV AMPLIFIER 45UV5-1007/1008/1009\n\n E1R3 * AUTOCHECK INFRARED AMPLIFIER 48PT2\n\n EDC1 Direct coupled amplifier Insight, Phoenix\n\n EDC2 Direct coupled amplifier Insight, Phoenix\n\n * The E1R1 is not to be used with solid fuel applications. It is designed for oil fog rejection. The E1R3 is\n suitable for all fuel applications and does not contain oil fog rejection. Equipment should be tested for the\n proper application of this amplifier to avoid property damages or personal injury.\n\n\n WARNING: E1R2 and E1R3 are not replacements for E1R1. E1R2 has increased flame sensi-\n tivity which may result in unsafe operation if not properly applied. E1R3 does not provide oil\n spray rejection protection which may result in unsafe operation if not properly applied.\n Consult factory before installation.\n\n\n\nFLAME SCANNERS\n\n\n\n\n CAUTION: The UV1, UV2, UV8A, UV90 and 45UV3 ultra-violet flame scanners and associ-\n ated amplifier modules are non self-checking UV systems and should be applied only to burn-\n ers that cycle after (e.g.: a minimum of once per 12 hours) in order for the safety checking\n circuit to be exercised. If component checking is required during burner operation for con-\n stantly fired burners, utilize the self-checking ultra-violet flame scanners (45UV5) with asso-\n ciated amplifier module (EUVS4) or the infrared flame scanner (48PT2) with associated\n AutoCheck amplifier (E1R1).\n\n2\n\f \n\n\n\n\nSCANNER SELECTION\n FIREYE PART NUMBER DESCRIPTION USE WITH AMPLIFIER BULLETIN\n 48PT2-1003 Infrared 1/2” straight mount 96” (2438mm) TC-ER cable E1R1, E1R2 * and SC-103\n 48PT2-9003 Infrared 1/2” 90angle mount 96” (2438mm) TC-ER cable E1R3 *\n 48PT2-1007 Infrared 1/2” straight mount 48” (1219mm) TC-ER cable\n 48PT2-9007 Infrared 1/2” 90 angle mount 48” (1219mm) TC-ER cable\n UV1A3 1\n /2” NPT, 36” (915mm) TC-ER cable EUV1 SC-102\n UV1A6 1\n /2” NPT, 72” (1830mm) TC-ER cable\n UV8A 1/ ” NPT, 72” (1830mm) unshielded leads, 90 right angle mount\n 2\n 3\n UV2 /8” NPT, 36” (915mm) TC-ER cable\n 3\n UV2A6 /8” NPT, 72” (1830mm) TC-ER cable\n UV2C Replaced with UV2\n 45UV2-1020 1” NPT mount 60 Hz, 72” (1830mm) unshielded leads\n 3/ ” Sleeve/setscrew mount, 72” (1830mm) unshielded leads\n 45UV3-1050 4\n UV90-3 36” (915mm) shielded leads\n UV90-6 72” (1828mm) shielded leads\n UV90-9 108” (2742mm) shielded leads\n 69ND1-1000K4 Flame rod 12”, 1/2” NPT mount ERT1 SC-103\n 69ND1-1000K6 Flame rod 18”, 1/2” NPT mount\n 69ND1-1000K8 Flame rod 24”, 1/2” NPT mount\n 45UV5-1007 Self-check UV 1” BSP, 72” (1830mm) unshielded leads, 230 VAC EUVS4 SC-101\n 45UV5-1008 Self-check UV 1” BSP, 72” (1830mm) unshielded leads, 120 VAC\n 45UV5-1009 Self-check UV 1” NPT, 72” (1830mm) unshielded leads, 120 VAC\n\n\n * WARNING: E1R2 and E1R3 are not replacements for E1R1.\n Consult factory before installation.\n\n\n The flame amplifier module is installed in the third set of guide channels found in the EB700\n FLAME-3G-OTH-02815 chassis. It is marked “AMPLIFIER MODULE.” Do not force the module into\n position.\n Amplifier Module (One Required)\n E1R1\n E1R2\n E1R3\n EUV1\n EUVS4\n ERT1\n\n\n\n\n CAUTION: REMOVE POWER FROM THE WIRING BASE BEFORE TRYING TO\n REPLACE THE FLAME AMPLIFIER MODULE.\n\n\n\n 3\n\f \n\n\n\n\nIMPORTANT\n When wiring to the FLAME-3G-OTH-02815 control wiring\n base, scanner terminal S2 must be grounded when using\n a flame rod. When using an infrared scanner (48PT2),\n Flame Rod\n ground S2 on all EB700’s labeled “ENG CODE 00.”\n All other ENG CODE models do not require that S2 be\n grounded. Do not ground S2 when using ultra violet\n scanners.\n Voltage measurements, S1-S2 with no flame present:\n\n\n AMPLIFIER S1-S2\n\n EUV1 560 VAC\n EUVS4\n ERT1 270 VAC\n E1R1 12 - 15 VDC\n TERMINAL WIRING BASE E1R2\n E1R3\n\n\n Refer to Service Note SN-100 for recommended\n grounding techniques.\n\n\n\n\nNOTICE\n When Fireye products are combined with equipment manufactured by others and/or integrated into\n systems designed or manufactured by others, the Fireye warranty, as stated it its General Terms and\n Conditions of Sale, pertains only to the Fireye products and not to any other equipment or to the com-\n bined system or its overall performance.\n\n\nWARRANTIES\n FIREYE guarantees for one year from the date of installation or 18 months from date of manufacture\n of its products to replace, or, at its option, to repair any product or part thereof (except lamps, elec-\n tronic tubes and photocells) which is found defective in material or workmanship or which otherwise\n fails to conform to the description of the product on the face of its sales order. THE FOREGOING\n IS IN LIEU OF ALL OTHER WARRANTIES AND FIREYE MAKES NO WARRANTY OF\n MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED. Except as\n specifically stated in these general terms and conditions of sale, remedies with respect to any product\n or part number manufactured or sold by Fireye shall be limited exclusively to the right to replacement\n or repair as above provided. In no event shall Fireye be liable for consequential or special damages of\n any nature that may arise in connection with such product or part.\n\n\n\n\n FIREYE ® EAMP1\n 3 Manchester Road…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fireye Flame-3G-OTH-02815 Amplifier Modules are programmer and amplifier modules available in models E1R1, EUV1, ERT1, and EUVS4. These cULus and FM Approved modules offer direct coupling with Insight and Phoenix scanners, providing efficient flame monitoring.

Frequently Asked Questions

What are the Fireye E1R1, EUV1, ERT1, and EUVS4 amplifier modules used for?

These Fireye amplifier modules are used with the Flame-3G-OTH-02815 system to provide flame scanning using AutoCheck infrared scanners, standard ultraviolet scanners, flame rods, and ultraviolet self-check scanners. Each module must be selected based on the scanner type and inserted into the appropriate Flame-3G-OTH-02815 chassis.

What are the specifications of the Fireye E1R1 amplifier module?

The Fireye E1R1 is an AutoCheck infrared amplifier module designed for use with the 48PT2 scanner. It is not for solid fuel applications and provides oil fog rejection. The module is cULus and FM Approved and must be inserted into the Flame-3G-OTH-02815 chassis for operation.

Where to buy Fireye amplifier modules in Singapore?

3G Electric supplies Fireye amplifier modules including the E1R1, EUV1, ERT1, and EUVS4 to customers in Singapore. We source these components and handle logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on your order.

How do I select the correct Fireye amplifier module for my scanner?

Select the Fireye amplifier module based on your scanner type. For example, the EUV1 works with UV1A, UV8A, 45UV3, and UV90 scanners, while the ERT1 is for the 69ND1 flame rod. The E1R1 is for the 48PT2 infrared scanner. Always refer to Fireye Bulletin E-1101 for proper installation and wiring.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye programmer & amplifier modules. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Flame-Monitor E300 Expansion Module. The E300 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
Fireye
Flame-Monitor E300 Expansion Module. The E300 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
Flame sensor for burner management systems. Detects and amplifies flame signals to support safe burner operation in commercial and industrial combustion applications
Fireye
Flame sensor for burner management systems. Detects and amplifies flame signals to support safe burner operation in commercial and industrial combustion applications
Flame sensor amplifier module for burner management systems. Detects and amplifies flame signals from ultraviolet or infrared scanners. Used in industrial boilers, furnaces, and process heaters
Fireye
Flame sensor amplifier module for burner management systems. Detects and amplifies flame signals from ultraviolet or infrared scanners. Used in industrial boilers, furnaces, and process heaters
Flame-Monitor E320 Expansion Module. The E320 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
Fireye
Flame-Monitor E320 Expansion Module. The E320 expansion module provides operational information and reduces troubleshooting time and expense. It expands the standard display messages of the Fireye Flame-Monitor to identify the specific limit in the operating control circuit or running interlock circuit which caused the burner shutdown or lockout
25SU3 Flame Signal Amplifier. The Fireye 25SU3-2100 also maximizes burner discrimination with its ability to accurately differentiate the pulse rates produced by the scanners
Fireye
25SU3 Flame Signal Amplifier. The Fireye 25SU3-2100 also maximizes burner discrimination with its ability to accurately differentiate the pulse rates produced by the scanners
45UV5 Series UV Flame Scanners. These 45UV5 models are used only with the Flame-Monitor™, BurnerLogix™, D-Series, FlameWorx, MicroM and some P-Series Fireye control models to provide flame safeguard and monitoring systems for supervised manual, semi-automatic and fully automatic single burner boilers, process ovens and heaters
Fireye
45UV5 Series UV Flame Scanners. These 45UV5 models are used only with the Flame-Monitor™, BurnerLogix™, D-Series, FlameWorx, MicroM and some P-Series Fireye control models to provide flame safeguard and monitoring systems for supervised manual, semi-automatic and fully automatic single burner boilers, process ovens and heaters

More from Fireye

View all Fireye parts
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
Fireye
M-Series II Amplifier Modules. The Fireye MART1, MART3, MART1T, MAUV1, MAUV3, and MAUV1T are advanced Amplifier Modules designed for use with the Fireye Modular M-SERIES II Control. These versatile amplifier modules are essential for flame scanning, offering compatibility with Fireye’s standard ultraviolet (UV) scanners and flame rods to ensure accurate flame detection and system performance
MicroM Programmer Modules. The Fireye MicroM Series is a compact, microprocessor-based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial heating and process equipment, regardless of fuel type. The system offers significant advantages, including the elimination of discrete components traditionally used for timing functions, providing a more reliable and efficient solution for industrial applications
Fireye
MicroM Programmer Modules. The Fireye MicroM Series is a compact, microprocessor-based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial heating and process equipment, regardless of fuel type. The system offers significant advantages, including the elimination of discrete components traditionally used for timing functions, providing a more reliable and efficient solution for industrial applications
Flame-Monitor EP Programmer Modules. The Fireye programmer modules—including EP100S, EP200S, EP300S (extended purge), EP160, EP161 (extended MTFI), EP163 (programmable), EP170, EP174 (early spark termination), EP165, EP166 (pilot stabilization), EP177 (early spark termination and programmable operating parameters), EP260, EP265 (pilot stabilization), EP270 (early spark termination), EP380, EP381, EP382, EP383, and EP390—are designed for use with the Flame-Monitor Burner Management Control System
Fireye
Flame-Monitor EP Programmer Modules. The Fireye programmer modules—including EP100S, EP200S, EP300S (extended purge), EP160, EP161 (extended MTFI), EP163 (programmable), EP170, EP174 (early spark termination), EP165, EP166 (pilot stabilization), EP177 (early spark termination and programmable operating parameters), EP260, EP265 (pilot stabilization), EP270 (early spark termination), EP380, EP381, EP382, EP383, and EP390—are designed for use with the Flame-Monitor Burner Management Control System
MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4 amplifier modules are designed for use with the Fireye Modular MicroM control system. These modules enable reliable flame scanning using Fireye’s UV, self-check, IR, CdS scanners, and flame rods
Fireye
MicroM Amplifier Modules. The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1, and MECD4 amplifier modules are designed for use with the Fireye Modular MicroM control system. These modules enable reliable flame scanning using Fireye’s UV, self-check, IR, CdS scanners, and flame rods