Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Fireye Nexus PPC6000 Parallel Positioning - Parallel Positioning Controls
FireyeParallel Positioning Controls

Fireye Nexus PPC6000 Parallel Positioning

The Fireye Nexus 3G-OTH-02807 is a parallel positioning control from the 3G-OTH-02807 model series. It carries approvals including CE, FM Approved, and UL Listed.

SKU 3G-OTH-02807

Also listed as: PPC 6000 · PPC-6000

Brand
Fireye
Item
Nexus PPC6000 Parallel Positioning
Category
Parallel Positioning Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Fireye
Models
PPC6000
Category
Parallel Positioning Controls
Approvals
CE, FM Approved, UL Listed

Datasheet Content

[{"filename":"MF-00-8-010P-0-003-A-Nexus_NX6100_PPC6000.pdf","text":"Nexus Combustion Efficiency Systems\n ®\n\n\n\nBurner Controls\n\nNX6100 and 3G-OTH-02807\nDesigned for combustion efficiency applications\noptimized for performance and affordability\nBenefits\n • Increases efficiency\n • Reduces fuel consumption\n • Reduces emissions and greenhouse gases\n • Reduces downtime and maintenance\n\nPPC6000\nAir/Fuel Ratio Control NX6100\nRequires flame safeguard system such as BurnerLogiX® Advanced Burner Management System with Parallel\nor Flame Monitor® Positioning and Integrated Flame Safeguard\nFeatures (3G-OTH-02807 & NX6100) Features (NX6100 Only)\n • Four fuel profiles and sequencing for up to four boilers As per PPC600 plus:\n • Twelve key keypad or industrially hardened 10.4” color • Integrated fully functional and configurable flame\n touchscreen display options safeguard\n • Up to ten 24 volt servo motors from wide range: 3, 10, • Built-in UV, UV Self Check and IR Detection,\n 15, 37 ft/lb. compatible with Fireye integrated InSight and\n • Nine user defined digital inputs (NX6100) Phoenix Scanners\n • CANBus two wire communication for simplified wiring • UVSC CANbus sensors for flame monitoring\n • Four user defined digital inputs (3G-OTH-02807) • Two scanners per profile with scanner selection by\n • Optional external O2/CO trim interface profile (UV profile one, IR profile two)\n • Optional VSD with two VSD and one 4-20 mA. outputs • Recycle on pilot flame loss\n • Optional MODbus RTU card • Digital pressure switches for valve proving (analog\n • Optional water level, draft and total dissolved solids pressure sensor option still available)\n controller\n • Two PID control loops per profile\n • Master OEM pass code feature\n • FGR hold off (time or temperature)\n • Combustion air pressure profiling using CANbus sensor\n (independent VFD feedback)\n\nTechnical Specifications NX6100 3G-OTH-02807\nSupply Voltage 120/230 VAC, 50/60Hz 120/230 VAC, 50/60Hz\n Approx. 60 VA Approx. 60 VA\nPower Consumption\n (with display attached & no accessories) (with keypad display attached & no accessories)\nAmbient Temperature Range 32° to 140°F (0° to 60°C) 32° to 140°F (0° to 60°C)\n Display: 6 VA Display: 6 VA\n Oxygen Probe: 12 VA Oxygen Probe: 12 VA\n NCX04: 3 VA NCX04: 3 VA\nTypical Loads\n NCX12: 5 VA NCX12: 5 VA\n NXC20: 10 VA NXC20: 10 VA\n NXC40: 18 VA NXC40: 18 VA\n 8.27” (210mm) wide x 4.92” (125mm) high 8.27” (210mm) wide x 4.92” (125mm) high\nControl Unit Dimensions\n x 3.15” (80mm) deep x 3.15” (80mm) deep\nWeight 4.70 lbs (2.13kg) 4.70 lbs (2.13kg)\n\nfireye.com\n\fNexus Combustion Efficiency Systems\n ®\n\n\n\nBurner Controls\n BURNER CONTROL SYSTEM\n An electronic parallel positioning and O2 trim combustion control system,\n the NX61000 and 3G-OTH-02807 models offers integrated burner management.\n The addition of the NXEXP300 expansion module offers water level, draft\n and total dissolved solids functionality.\n\n NEXUS SERVO MOTORS NXC Series\n EFFICIENCY\n CONTROLLER\n\n NX6100\n 3G-OTH-02807\n NXEXP300\n\n 4Nm 20Nm 40Nm\n\n\n\n DISPLAYS OXYGEN\n MEASUREMENT\n\n\n\n\n NXO2TRIM\n NX6220 / NX6330 NXTSD104\n\n\n SENSORS\n\n\n\n\n NX104x NX102x NX103x BLPS NXIATS TS350/752\n\n\n\n SCANNERS\n\n\n\n\n UV1AL 45UV5 48PT2 85UVF/IRF 95DSS3\n\n\nFor more information, please contact your local Fireye Distributor.\nfireye.com\nMF-00-8-010P-0-003-A (2025/01)\nAll trademarks and service marks referred herein are property of their respective owners.\n©2025 Fireye. All Rights Reserved.\n\n Join us on"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fireye Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fireye Nexus 3G-OTH-02807 is a parallel positioning control from the 3G-OTH-02807 model series. It carries approvals including CE, FM Approved, and UL Listed.

Frequently Asked Questions

What is the Fireye Nexus 3G-OTH-02807 used for?

The Fireye Nexus 3G-OTH-02807 is a parallel positioning control used to optimize air/fuel ratio in industrial burners, increasing combustion efficiency and reducing fuel consumption and emissions. It is typically paired with a Fireye BurnerLogix flame safeguard system for advanced burner management.

What are the specifications of the Fireye 3G-OTH-02807?

The Fireye 3G-OTH-02807 operates on 120/230 VAC, 50/60Hz with approximately 60 VA power consumption. It supports up to ten 24 VDC servo motors (3, 10, 15, 37 ft/lb), four user-defined digital inputs, and optional O2/CO trim, VSD, MODbus RTU, and water level controller. Dimensions are 210 mm x 125 mm x 80 mm, weight 2.13 kg.

Where to buy the Fireye 3G-OTH-02807 in Singapore?

3G Electric supplies the Fireye 3G-OTH-02807 parallel positioning control to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this Fireye combustion efficiency component.

How to install the Fireye 3G-OTH-02807?

Install the Fireye 3G-OTH-02807 by mounting the control unit in a suitable enclosure within the ambient temperature range of 0° to 60°C. Connect CANBus two-wire communication to servo motors and integrate with a Fireye BurnerLogix flame safeguard system. Follow Fireye's wiring diagrams and ensure proper grounding per local codes.

Used in

Common applications for Fireye
Power-plant auxiliary boiler — M-Series II controller with UV flame scanner, programmed for gas/oil switchover and flame-presence monitoring.
Refinery process heater — MP100E programmer module managing multi-stage ignition and flame-out shutdown interlocks on high-pressure burners.
Petrochemical facility thermal oxidizer — MAUV1T UV amplifier module processing scanner signal from high-temperature burner housings with immune-response filtering.
Large-scale industrial oven (metal treating) — M-Series II with remote reset capability and dual-fuel solenoid isolation for operator safety and burner protection.
Cogeneration plant fuel-gas burner — Fireye scanner and modular controller stack integrated into BMS with remote monitoring of flame status and controller fault codes.

Fireye Products

3G Electric supplies Fireye parallel positioning controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
PMSTR-6000 Plant Master for NX6100 and PPC6000. The Fireye PMSTR-6000 Plant Master offers sequencing and control for up to ten NX6100 or PPC6000 efficiency controls for steam and hot water plant applications. A 10.4” touchscreen interface is supplied for setup and monitoring
Fireye
PMSTR-6000 Plant Master for NX6100 and PPC6000. The Fireye PMSTR-6000 Plant Master offers sequencing and control for up to ten NX6100 or PPC6000 efficiency controls for steam and hot water plant applications. A 10.4” touchscreen interface is supplied for setup and monitoring
The Fireye NX6100 is an integrated parallel positioning control for burner management systems. It coordinates fuel and air damper actuators to optimize combustion efficiency and reduce emissions. Suitable for commercial and industrial boilers, furnaces, and process heaters
Fireye
The Fireye NX6100 is an integrated parallel positioning control for burner management systems. It coordinates fuel and air damper actuators to optimize combustion efficiency and reduce emissions. Suitable for commercial and industrial boilers, furnaces, and process heaters
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
Fireye
PF Series MBPF-100S Burner Control. The MBPF-100S, MB-600PF, MBPF-200S and MBPF-202S modules provide visual indication and electrical output that signal the user regarding flame presence in a combustion chamber. The module uses Fireye optical ultra-violet scanners and/or flame rods to sense flame presence independently or as components in a burner management system
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems
Fireye
MB Series MB600S Burner Control. MB SERIES control has been engineered to meet the operational, safety and reliability requirements demanded by the industrial process heat market. It is a fully integrated control, complete with all functions built into one module, offering the opportunity to greatly reduce cost and space requirements normally required by other non-integrated systems
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
Fireye
D-Series 70D40 and 70D41 Burner Control. Plug-in Amplifier Modules permit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared, or rectification methods of flame detection. The control system includes a safe start check, effective on each start. If the flame signal (real or simulated) is detected, the unit cannot be started
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks
Fireye
BurnerLogiX Y Flame Safeguard. The BurnerLogix flame safeguard controler boast a sophisticated array of features designed to enhance efficiency, safety, and ease of use in combustion systems. Employing built-in techniques and algorithms, the BurnerLogix is equipped to learn and adapt to the unique characteristics of the fuel being burned. This intelligent system dynamically sets internal thresholds, optimizing detection accuracy under a diverse range of operating conditions. When firing conditions deviate unfavorably, the adaptive IR system swiftly and safely initiates a shutdown of the burner, mitigating potential risks

More from Fireye

View all Fireye parts
Nexus PPC4000 Parallel Positioning. When combined with a Fireye flame safeguard system such as the BurnerLogix™ control, the PPC4000 offers a compact parallel positioning system
Fireye
Nexus PPC4000 Parallel Positioning. When combined with a Fireye flame safeguard system such as the BurnerLogix™ control, the PPC4000 offers a compact parallel positioning system
Nexus NXF4000 Parallel Positioning. The Fireye NXF4000 is an advanced burner management controller with an internal flame safeguard, designed to operate burners firing liquid or gaseous fuels. NXF4000 supports up to four servos and two VFD channels per profile, optional touchscreen interface, 15 configurable digital inputs, optional valve proving, thermal shock, hot standby, integrated peer-to-peer sequencing and more. Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs
Fireye
Nexus NXF4000 Parallel Positioning. The Fireye NXF4000 is an advanced burner management controller with an internal flame safeguard, designed to operate burners firing liquid or gaseous fuels. NXF4000 supports up to four servos and two VFD channels per profile, optional touchscreen interface, 15 configurable digital inputs, optional valve proving, thermal shock, hot standby, integrated peer-to-peer sequencing and more. Add-on options include oxygen trim, plant master for centralized control and communication gateway to support most BMS/PLC/SCADA needs
Nexus NXEXP300 Water Level Control. The NXEXP300 expands the capability of the parallel positioning system by adding valuable safety-rated digital inputs, sequence draft control, boiler water level control and total dissolved solids (TDS) surface and bottom blowdown control. The small (5” L x 8.5” W x 3.75H) footprint, adjustable voltage (120/230, 50/60 hz.) and simplified wiring provide easy retrofit to existing Fireye systems
Fireye
Nexus NXEXP300 Water Level Control. The NXEXP300 expands the capability of the parallel positioning system by adding valuable safety-rated digital inputs, sequence draft control, boiler water level control and total dissolved solids (TDS) surface and bottom blowdown control. The small (5” L x 8.5” W x 3.75H) footprint, adjustable voltage (120/230, 50/60 hz.) and simplified wiring provide easy retrofit to existing Fireye systems
Nexus NX6300 Parallel Positioning. The newest member of the versatile 6000 series family of combustion efficiency burner controls that can be configured to control a variety of burner applications
Fireye
Nexus NX6300 Parallel Positioning. The newest member of the versatile 6000 series family of combustion efficiency burner controls that can be configured to control a variety of burner applications
Nexus NX6100 Integrated Parallel Positioning. Fireye proudly presents the NX6100, an advanced fully integrated parallel positioning system. Designed to deliver unparalleled performance in the smallest footprint in the industry—measuring just 5 x 8.25 x 3.75 inches—the NX6100 sets a new standard in efficiency and functionality. Also available in Nexus PPC6000
Fireye
Nexus NX6100 Integrated Parallel Positioning. Fireye proudly presents the NX6100, an advanced fully integrated parallel positioning system. Designed to deliver unparalleled performance in the smallest footprint in the industry—measuring just 5 x 8.25 x 3.75 inches—the NX6100 sets a new standard in efficiency and functionality. Also available in Nexus PPC6000