Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 49.2 in Range - Reflective Ultrasonic Liquid Level Sensor Transmitters
FLOWLINEReflective Ultrasonic Liquid Level Sensor Transmitters

FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 49.2 in Range

The FLOWLINE DX10-01 is a noncontact reflective ultrasonic liquid level sensor transmitter with a 1 in NPT connection and a 1 3/8 in antenna diameter. It offers a 49.2 in range with an accuracy of 1/8 in and operates…

SKU 3G-OTH-92339

Brand
FLOWLINE
Item
Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 49.2 in Range
Category
Reflective Ultrasonic Liquid Level Sensor Transmitters
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

FLOWLINE
Manufacturer Part Number
DX10-01
Type
NPT
Range
49.2 in
Accuracy
1/8 in
Antenna Dia
1 3/8 in
Display Type
None
Max. Voltage
24V DC
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLOWLINE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLOWLINE DX10-01 is a noncontact reflective ultrasonic liquid level sensor transmitter with a 1 in NPT connection and a 1 3/8 in antenna diameter. It offers a 49.2 in range with an accuracy of 1/8 in and operates on 24V DC. This model has no display.

Frequently Asked Questions

What is the FLOWLINE DX10-01 ultrasonic level sensor used for?

The FLOWLINE DX10-01 is a noncontact reflective ultrasonic liquid level sensor transmitter used for continuous level measurement in tanks or vessels. It is suitable for water, wastewater, and chemical applications where contact with the liquid must be avoided.

What are the specifications of the FLOWLINE DX10-01?

The FLOWLINE DX10-01 has a 49.2 in range, 1/8 in accuracy, 1 in NPT connection, and 1 3/8 in antenna diameter. It operates on 24V DC and has no display. The manufacturer part number is DX10-01.

Where to buy the FLOWLINE DX10-01 worldwide?

You can source the FLOWLINE DX10-01 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to install the FLOWLINE DX10-01 ultrasonic level sensor?

Install the FLOWLINE DX10-01 with the sensor face parallel to the liquid surface, avoiding obstructions in the beam path. Use the 1 in NPT fitting for mounting. Ensure the 24V DC power supply is stable and follow standard wiring practices for ultrasonic sensors.

Used in

Common applications for FLOWLINE
Chemical processing — FLOWLINE ultrasonic level switch (LU10-1405) for corrosive liquid level detection in storage tanks.
Water and wastewater treatment — FLOWLINE guided wave radar sensor (LG10-1003-01) for level measurement in clarifiers and lift stations.
Oil and gas — FLOWLINE rod guided wave radar (LG10-0003-01) for level monitoring in separator vessels and sump tanks.
Food and beverage — FLOWLINE level controller (LC52-1001) for pump control in CIP (clean-in-place) systems.
Pharmaceutical manufacturing — FLOWLINE coaxial guided wave radar (LG10-1003-01) for precise level measurement in stainless steel reactors.
Industrial tank farms — FLOWLINE reducer bushing (LM52-1400) for adapting ultrasonic sensors to existing tank openings.

FLOWLINE Products

3G Electric supplies FLOWLINE reflective ultrasonic liquid level sensor transmitters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 49.2 in Range, NPT (MPN DS14-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 24V AC/DC; Output Voltage Range: 4 to 20mA; Accuracy: 1/8 in; Display Type: None.
FLOWLINE
FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 49.2 in Range, NPT (MPN DS14-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 24V AC/DC; Output Voltage Range: 4 to 20mA; Accuracy: 1/8 in; Display Type: None.
FLOWLINE Noncontact Ultrasonic Level Sensor: 2 in NPT, 2 3/8 in Antenna Dia, 314.4 in Range, NPT (MPN LU28-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 24V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: None.
FLOWLINE
FLOWLINE Noncontact Ultrasonic Level Sensor: 2 in NPT, 2 3/8 in Antenna Dia, 314.4 in Range, NPT (MPN LU28-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 24V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: None.
FLOWLINE Noncontact Ultrasonic Level Sensor: 2 in NPT, 2 3/8 in Antenna Dia, 314.4 in Range, NPT (MPN LU83-5101). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Noncontact Ultrasonic Level Sensor: 2 in NPT, 2 3/8 in Antenna Dia, 314.4 in Range, NPT (MPN LU83-5101). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 117.6 in Range, NPT (MPN LU80-5101). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 117.6 in Range, NPT (MPN LU80-5101). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 117.6 in Range, NPT (MPN LU27-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 24V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: None.
FLOWLINE
FLOWLINE Noncontact Ultrasonic Level Sensor: 1 in NPT, 1 3/8 in Antenna Dia, 117.6 in Range, NPT (MPN LU27-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 24V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: None.
FLOWLINE Noncontact Ultrasonic Level Sensor: 2 in NPT, 2 3/8 in Antenna Dia, 216 in Range, NPT, LCD (MPN LU81-5101). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Noncontact Ultrasonic Level Sensor: 2 in NPT, 2 3/8 in Antenna Dia, 216 in Range, NPT, LCD (MPN LU81-5101). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.

More from FLOWLINE

View all FLOWLINE parts
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG01-0001-40). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: 3 mm; Display Type: None.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG01-0001-40). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: 3 mm; Display Type: None.
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG06-0001-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG06-0001-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE Reflective Ultrasonic Level Sensor: 3 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG12-0011-00). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 3 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG12-0011-00). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG03-0001-40). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: None.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG03-0001-40). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: None.
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG01-0011-41). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: 3 mm; Display Type: None.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG01-0011-41). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: 3 mm; Display Type: None.
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG06-0011-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 2 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG06-0011-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE Reflective Ultrasonic Level Sensor: 3 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG12-0011-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 3 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG12-0011-01). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE Reflective Ultrasonic Level Sensor: 3 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG12-0001-00). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.
FLOWLINE
FLOWLINE Reflective Ultrasonic Level Sensor: 3 in NPT, For Chemicals/Oil/Wastewater/Water Media Type (MPN UG12-0001-00). Key specifications — Brand: FLOWLINE; Max. Voltage: 28V DC; Output Voltage Range: 4 to 20mA; Accuracy: +/-0.2% of Range; Display Type: LCD.