Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
FLUKE 28IIEX/ETL Intrinsically Safe TRMS Digital Multimeter - Intrinsically Safe Multimeters
FLUKEIntrinsically Safe Multimeters

FLUKE 28IIEX/ETL Intrinsically Safe TRMS Digital Multimeter

The FLUKE Digital Multimeter: TRMS is an intrinsically safe multimeter with a 20,000-count display and CAT IV 600V rating, supporting 1,000 V max AC voltage measurement. It features an IP67 rating for dust and water…

SKU 3G-OTH-222460

Also listed as: FLUKE28IIEXETL · FLUKE 28IIEX ETL · FLUKE-28IIEX-ETL

Brand
FLUKE
Item
28IIEX/ETL Intrinsically Safe TRMS Digital Multimeter
Part Number
FLUKE-28IIEX/ETL
Category
Intrinsically Safe Multimeters
Available to Order
Also known as:FLUKE-28IIEX/ETLFLUKE
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Compliance & shipping

Hazardous material
Not classified as hazardous
California Prop 65 warning
No warning recorded
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Ships under standard freight

Technical Specifications

FLUKE
Manufacturer Part Number
FLUKE-28IIEX/ETL
Type
CAT IV 600V, IP67
UNSPSC
41113630
Weight
1.54 lb
Includes
Alligator Clips; Batteries; Test Leads
Data Hold
Yes
Standards
Class 1 Div 1 Groups A-D T4; Class 1 Zone 1 AEX IA IIC T4
Diode Test
Yes
Duty Cycle
Duty Cycle Test Included
Fuse Access
No
Pulse Width
No
Auto Ranging
Yes
Battery Size
AAA
Catalog Page
516
Data Logging
Yes
Display Type
Backlit LCD
Current Units
A; mA
Overall Depth
7.8 in
Overall Width
3.9 in
Auto Power Off
Yes
Battery Access
Yes
Overall Height
2.5 in
Battery Voltage
1.5 V
Thermal Imaging
No
Multimeter Style
Full Size
Removable Screen
No
Special Features
IP67; Rubber Holster
Battery Chemistry
Alkaline
Country of Origin
USA (subject to change)
Instrument Counts
20,000
Software Included
No
Testing Functions
AC Current AC Voltage Capacitance DC Current DC Voltage Frequency Resistance Temperature Conductance
Audible Continuity
Yes
Bar Graph Included
Yes
Batteries Included
Yes
Intrinsically Safe
Yes
True RMS Bandwidth
20 kHz
Includes Auto Sensing
No Auto Sensing Included
Minimum/Maximum Memory
Min/Max
AC Response Calculation
TRMS AC Response Calculation This measurement determines how a circuit responds when an AC signal is applied to it.
Current Leakage Testing
No
Max AC Volt Measurement
1,000 V
Basic AC Current Accuracy
±(1% + 2)
Basic AC Voltage Accuracy
±(0.7% + 4)
Basic DC Current Accuracy
±(0.2% + 4)
Basic DC Voltage Accuracy
±0.05% + 1 Digit
Maximum Storage Temperature
140 °F
Min-Max-Avg Button Included
Yes
Minimum Storage Temperature
-67 °F
Manufacturers Warranty Length
3 yr
Maximum Frequency Measurement
200 kHz
Maximum Operating Temperature
122 °F
Minimum Frequency Measurement
0.5 Hz
Minimum Operating Temperature
5 °F
Frequency Measurement Accuracy
±(0.005% + 1)
Maximum AC Current Measurement
10 A
Maximum AC Voltage Measurement
1,000 V
Maximum DC Current Measurement
10 A
Maximum DC Voltage Measurement
1,000 V
Maximum Resistance Measurement
50 megaohm
Minimum AC Current Measurement
0.1 uA
Minimum AC Voltage Measurement
0.1 V
Minimum DC Current Measurement
0.1 uA
Minimum DC Voltage Measurement
0.1 V
Minimum Resistance Measurement
0.1 ohm
Maximum Capacitance Measurement
9,999 uF
Maximum Temperature Measurement
1,994 °F
Minimum Capacitance Measurement
10 nF
Minimum Temperature Measurement
-328 °F
Resistance Measurement Accuracy
±0.2%
Calibration Certificate Included
No Certification Included
Capacitance Measurement Accuracy
±(1% + 2)
Frequency Measurement Resolution
0.5 Hz
Temperature Measurement Accuracy
±(1% + 10)
Capacitance Measurement Resolution
10 nF

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE Digital Multimeter: TRMS is an intrinsically safe multimeter with a 20,000-count display and CAT IV 600V rating, supporting 1,000 V max AC voltage measurement. It features an IP67 rating for dust and water protection, and the test leads are not included. This model, MPN FLUKE-28IIEX/ETL, is designed for hazardous environments requiring intrinsic safety.

Frequently Asked Questions

What is the FLUKE 28IIEX/ETL digital multimeter used for?

The FLUKE 28IIEX/ETL is an intrinsically safe TRMS digital multimeter designed for hazardous environments requiring explosion-proof ratings. It is used by plant engineers and maintenance technicians for measuring AC voltage up to 1,000 V in oil refineries, chemical plants, and other explosive atmospheres where safety is critical.

What are the specifications of the FLUKE 28IIEX/ETL multimeter?

The FLUKE 28IIEX/ETL features a 20,000-count display, CAT IV 600V safety rating, and 1,000 V max AC voltage measurement. It has an IP67 rating for dust and water protection. Test leads are not included. This model is manufactured by FLUKE and is designed for intrinsic safety in hazardous locations.

Where to buy the FLUKE 28IIEX/ETL multimeter worldwide?

You can source the FLUKE 28IIEX/ETL multimeter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide this FLUKE model to customers across multiple industries.

How to select the right intrinsically safe multimeter for hazardous areas?

When selecting an intrinsically safe multimeter like the FLUKE 28IIEX/ETL, verify the device carries appropriate safety certifications for your zone (e.g., ATEX or IECEx). Check the CAT rating (e.g., CAT IV 600V) and environmental protection (IP67). Ensure the measurement range covers your application, such as 1,000 V AC for industrial systems.

Used in

Common applications for FLUKE
Electrical maintenance — Fluke 289 true-RMS digital multimeter for troubleshooting industrial power systems
Hazardous area instrumentation — Fluke 28IIEX/ETL intrinsically safe multimeter for use in explosive atmospheres
HVAC diagnostics — Fluke 561 infrared thermometer with contact probe for temperature measurement of ducts and motors
Pressure calibration — Fluke FLK-700HTPK2 hydraulic test pressure kit for calibrating pressure transmitters up to 10,000 psi
Process control — Fluke 80PK-22 Type K thermocouple probe for monitoring liquid and gas temperatures in process lines
Field calibration — Fluke 700TTH10K pneumatic test hose kit for connecting test pumps to transmitters in the field
Not sure this is the right part? Photo-identify it→

FLUKE Products

3G Electric supplies FLUKE intrinsically safe multimeters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

More from FLUKE

View all FLUKE parts →

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first