The FLUKE 80PK-11 is a Type K surface temperature probe for gas applications, with a flat tip and a temperature range of -19.3°F to 302°F (-30°C to 150°C). It offers an accuracy of ±1.5°C and features a 40-inch…

SKU 3G-OTH-179115

Also listed as: 80PK11 · 80PK 11

Brand
FLUKE
Item
80PK-11 Type K Thermocouple for Gas Applications, Flat Tip, -30 to 150 °C
Category
Thermocouples for Gas Applications
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FLUKE
Manufacturer Part Number
80PK-11
Type
±1.5°C/±2.7°F, Type K, Flat Tip
Accuracy
±1.5 °C
Cable Length
40 in
Cable Material
Hytrel Insulation
Process Mounting Connection
Hook-and-Loop

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE 80PK-11 is a Type K surface temperature probe for gas applications, with a flat tip and a temperature range of -19.3°F to 302°F (-30°C to 150°C). It offers an accuracy of ±1.5°C and features a 40-inch Hytrel-insulated cable with a hook-and-loop mounting connection.

Frequently Asked Questions

What is the FLUKE 80PK-11 surface temperature probe used for?

The FLUKE 80PK-11 is a Type K thermocouple probe designed for measuring surface temperatures on pipes, ducts, and flat surfaces in gas applications. Its flat tip and hook-and-loop mounting allow secure attachment for continuous monitoring in HVAC, industrial process, and maintenance environments.

What are the specifications of the FLUKE 80PK-11?

The FLUKE 80PK-11 is a Type K probe with a temperature range of -19.3°F to 302°F (-30°C to 150°C) and accuracy of ±1.5°C. It features a 40-inch Hytrel-insulated cable and a hook-and-loop mounting connection. The flat tip design ensures good surface contact for reliable readings.

Where to buy the FLUKE 80PK-11 worldwide?

3G Electric supplies the FLUKE 80PK-11 worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this probe to any international destination.

How to install the FLUKE 80PK-11 surface temperature probe?

To install the FLUKE 80PK-11, clean the surface and attach the probe using its hook-and-loop strap, ensuring the flat tip makes full contact. Connect the Type K thermocouple plug to a compatible meter. For best accuracy, avoid sharp bends in the Hytrel-insulated cable and keep the probe away from direct heat sources.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE thermocouples for gas applications. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
The FLIR TA60 is a Type K thermocouple with a rounded tip, designed for gas applications such as HVAC, flue gas analysis, and industrial gas-system diagnostics. It offers an accuracy of ±2.5°C and features a 3 ft 1 in PVC cable
FLIR
The FLIR TA60 is a Type K thermocouple with a rounded tip, designed for gas applications such as HVAC, flue gas analysis, and industrial gas-system diagnostics. It offers an accuracy of ±2.5°C and features a 3 ft 1 in PVC cable
Type K thermocouple probe for temperature measurement in liquids and gases. Accuracy ±3.96 °F (±2.2 °C). Suitable for process monitoring, HVAC diagnostics, and laboratory testing
FLUKE
Type K thermocouple probe for temperature measurement in liquids and gases. Accuracy ±3.96 °F (±2.2 °C). Suitable for process monitoring, HVAC diagnostics, and laboratory testing
Thermocouple probe with straight handle for temperature measurement in liquids and gases. Features a 4-inch probe length and accuracy of ±2.2°C (±3.96°F). Suitable for spot-checking or monitoring process temperatures in HVAC, food processing, and industrial maintenance applications
FLUKE
Thermocouple probe with straight handle for temperature measurement in liquids and gases. Features a 4-inch probe length and accuracy of ±2.2°C (±3.96°F). Suitable for spot-checking or monitoring process temperatures in HVAC, food processing, and industrial maintenance applications
Type K thermocouple with clamp tip for surface temperature measurement on pipes. Features a straight handle and accuracy of ±1.9°C. Suitable for HVAC, plumbing, and industrial process applications where hands-free monitoring is required
FLUKE
Type K thermocouple with clamp tip for surface temperature measurement on pipes. Features a straight handle and accuracy of ±1.9°C. Suitable for HVAC, plumbing, and industrial process applications where hands-free monitoring is required
Type K thermocouple for surface temperature measurement. Features a straight handle for stable contact on pipes, plates, or flat surfaces. Accuracy ±4.4°C from 0 to 127°C. Temperature range -127°C to 600°C
FLUKE
Type K thermocouple for surface temperature measurement. Features a straight handle for stable contact on pipes, plates, or flat surfaces. Accuracy ±4.4°C from 0 to 127°C. Temperature range -127°C to 600°C

More from FLUKE

View all FLUKE parts
Thermocouple probe with straight handle, 6-inch length, and ±1.1°C accuracy. Designed for immersion temperature measurement in gas flue or stack applications to monitor burner efficiency
FLUKE
Thermocouple probe with straight handle, 6-inch length, and ±1.1°C accuracy. Designed for immersion temperature measurement in gas flue or stack applications to monitor burner efficiency
Type K thermocouple with a rounded tip for gas applications. Measures temperatures from -40°C to 260°C with an accuracy of ±2.2 °C or 2% of reading, whichever is greater. Features a 3 ft PVC cable. Suitable for temperature measurement in gas systems and HVAC applications
FLUKE
Type K thermocouple with a rounded tip for gas applications. Measures temperatures from -40°C to 260°C with an accuracy of ±2.2 °C or 2% of reading, whichever is greater. Features a 3 ft PVC cable. Suitable for temperature measurement in gas systems and HVAC applications
Type K thermocouple with rounded tip for gas temperature measurement. Accuracy ±1.1°C (±2°F). Cable length 3 ft 4 in, Teflon (PTFE) insulation, 24 AWG wire. Suitable for HVAC, furnace, and process gas monitoring
FLUKE
Type K thermocouple with rounded tip for gas temperature measurement. Accuracy ±1.1°C (±2°F). Cable length 3 ft 4 in, Teflon (PTFE) insulation, 24 AWG wire. Suitable for HVAC, furnace, and process gas monitoring
Type T thermocouple for gas applications with a measurement range of -196°C to 350°C and accuracy of ±1°C from 0 to 350°C. Features a 3 ft 4 in PVC cable with 24 AWG wire. Suitable for temperature measurement in HVAC, process control, and laboratory environments
FLUKE
Type T thermocouple for gas applications with a measurement range of -196°C to 350°C and accuracy of ±1°C from 0 to 350°C. Features a 3 ft 4 in PVC cable with 24 AWG wire. Suitable for temperature measurement in HVAC, process control, and laboratory environments
Type K thermocouple with a 6-inch probe and straight handle, designed for immersion in gas media. Accuracy ±1.1°C. Suitable for temperature measurement in HVAC, process control, and laboratory settings
FLUKE
Type K thermocouple with a 6-inch probe and straight handle, designed for immersion in gas media. Accuracy ±1.1°C. Suitable for temperature measurement in HVAC, process control, and laboratory settings
Type-J thermocouple bead probe with Teflon insulated cable, 3 ft 3 in length. Accuracy ±1.1°C. Suitable for measuring gas temperatures in HVAC, furnace, and process monitoring applications
FLUKE
Type-J thermocouple bead probe with Teflon insulated cable, 3 ft 3 in length. Accuracy ±1.1°C. Suitable for measuring gas temperatures in HVAC, furnace, and process monitoring applications
Straight-handle thermocouple probe for measuring air and surface temperatures in gas applications. Temperature range -40°C to 816°C with accuracy ±2.2°C from -40°C to 293°C. Suitable for duct, pipe, and combustion equipment temperature checks
FLUKE
Straight-handle thermocouple probe for measuring air and surface temperatures in gas applications. Temperature range -40°C to 816°C with accuracy ±2.2°C from -40°C to 293°C. Suitable for duct, pipe, and combustion equipment temperature checks