Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FLUKE 9100S-B-156 Single-Block Drywell Calibrator, 95°F to 707°F / 35°C to 375°C - Single-Block Drywell Calibrators with Adjustable Setpoints
FLUKESingle-Block Drywell Calibrators with Adjustable Setpoints

FLUKE 9100S-B-156 Single-Block Drywell Calibrator, 95°F to 707°F / 35°C to 375°C

The FLUKE 9100S-B-156 is a single-block drywell calibrator with adjustable setpoints, covering a temperature range of 95°F to 707°F / 35°C to 375°C. It offers a stability of +/-0.1°C at 100°C and accommodates a stem…

SKU 3G-OTH-178565

Also listed as: 9100SB156 · 9100S B 156

Brand
FLUKE
Item
9100S-B-156 Single-Block Drywell Calibrator, 95°F to 707°F / 35°C to 375°C
Category
Single-Block Drywell Calibrators with Adjustable Setpoints
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FLUKE
Manufacturer Part Number
9100S-B-156
Type
95°F to 707°F /35°C to 375°C
Stability
+/-0.1°C at 100°C
For Stem Diameter
0.375

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE 9100S-B-156 is a single-block drywell calibrator with adjustable setpoints, covering a temperature range of 95°F to 707°F / 35°C to 375°C. It offers a stability of +/-0.1°C at 100°C and accommodates a stem diameter of 0.375 inches. This FLUKE calibrator is designed for drywall temperature calibration applications.

Frequently Asked Questions

What is the FLUKE 9100S-B-156 drywell calibrator used for?

The FLUKE 9100S-B-156 is a single-block drywell calibrator used for calibrating temperature sensors and probes in industrial and laboratory settings. It is ideal for verifying thermocouples, RTDs, and thermistors within a range of 95°F to 707°F (35°C to 375°C), offering adjustable setpoints for precise field or shop calibration.

What are the specifications of the FLUKE 9100S-B-156?

The FLUKE 9100S-B-156 drywell calibrator covers a temperature range of 95°F to 707°F (35°C to 375°C) with a stability of +/-0.1°C at 100°C. It accommodates a stem diameter of 0.375 inches and is a single-block design with adjustable setpoints. The manufacturer part number is 9100S-B-156.

Where to buy the FLUKE 9100S-B-156 worldwide?

You can source the FLUKE 9100S-B-156 drywell calibrator through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide competitive pricing and reliable sourcing for this FLUKE calibrator.

How to maintain the FLUKE 9100S-B-156 drywell calibrator?

To maintain the FLUKE 9100S-B-156, keep the drywell insert clean and free of debris. Regularly verify calibration against a reference standard to ensure stability within +/-0.1°C at 100°C. Avoid thermal shock by allowing the unit to cool before handling. Follow FLUKE's generic guidelines for drywell calibrator care to extend service life.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE single-block drywell calibrators with adjustable setpoints. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Ultraviolet flame scanner for detecting burner flame presence in combustion systems. Used in industrial boilers, furnaces, and process heaters to provide safety feedback to control systems
Fireye
Ultraviolet flame scanner for detecting burner flame presence in combustion systems. Used in industrial boilers, furnaces, and process heaters to provide safety feedback to control systems
Heater accessory temperature sensor for monitoring temperature in combustion and HVAC systems. Used in boilers, furnaces, and process heaters to support safe burner operation
Fireye
Heater accessory temperature sensor for monitoring temperature in combustion and HVAC systems. Used in boilers, furnaces, and process heaters to support safe burner operation
UV flame scanner for detecting flame presence in industrial burners, boilers, and furnaces. Used in burner management systems for flame supervision in commercial and industrial heating applications
Fireye
UV flame scanner for detecting flame presence in industrial burners, boilers, and furnaces. Used in burner management systems for flame supervision in commercial and industrial heating applications
Flame scanner for detecting flame presence in industrial burners, boilers, and furnaces. Used in combustion safety systems to verify ignition and monitor flame stability
Fireye
Flame scanner for detecting flame presence in industrial burners, boilers, and furnaces. Used in combustion safety systems to verify ignition and monitor flame stability
Dual function immersion controller for hydronic heating systems, combining circulator, high limit, and low limit functions. Temperature range 100°F to 240°F with adjustable differential from 5°F to 30°F. Includes auto/manual switch. Designed for horizontal mounting
HONEYWELL HOME
Dual function immersion controller for hydronic heating systems, combining circulator, high limit, and low limit functions. Temperature range 100°F to 240°F with adjustable differential from 5°F to 30°F. Includes auto/manual switch. Designed for horizontal mounting
Flame scanner for industrial combustion systems. Detects flame presence in burners used in boilers, furnaces, and process heaters. Provides safety and control feedback to prevent unburned fuel accumulation and enable safe shutdown
Fireye
Flame scanner for industrial combustion systems. Detects flame presence in burners used in boilers, furnaces, and process heaters. Provides safety and control feedback to prevent unburned fuel accumulation and enable safe shutdown

More from FLUKE

View all FLUKE parts
Single-block drywell calibrator with adjustable setpoints for temperature sensor verification. Temperature range 95°F to 707°F (35°C to 375°C) with stability ±0.07°C at 50°C. Accepts probes with stem diameter 0.125 in. Used for calibrating thermocouples, RTDs, and other temperature probes in industrial, HVAC, and laboratory settings
FLUKE
Single-block drywell calibrator with adjustable setpoints for temperature sensor verification. Temperature range 95°F to 707°F (35°C to 375°C) with stability ±0.07°C at 50°C. Accepts probes with stem diameter 0.125 in. Used for calibrating thermocouples, RTDs, and other temperature probes in industrial, HVAC, and laboratory settings
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
FLUKE
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range 95°F to 662°F / 35°C to 350°C. Stability ±0.05°C at 350°C. Accommodates two stem diameters of 3/16 in. Suitable for industrial process control, HVAC, and quality assurance applications
FLUKE
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range 95°F to 662°F / 35°C to 350°C. Stability ±0.05°C at 350°C. Accommodates two stem diameters of 3/16 in. Suitable for industrial process control, HVAC, and quality assurance applications
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
The FLUKE 9102S-156 is a single-block drywell calibrator with adjustable setpoints, covering a temperature range of -10°C to 122°C (14°F to 252°F). It provides stability of ±0.05°C and accommodates stem diameters of 0.1875 in. This instrument is used for field calibration of temperature sensors in applications such as HVAC and industrial maintenance
FLUKE
The FLUKE 9102S-156 is a single-block drywell calibrator with adjustable setpoints, covering a temperature range of -10°C to 122°C (14°F to 252°F). It provides stability of ±0.05°C and accommodates stem diameters of 0.1875 in. This instrument is used for field calibration of temperature sensors in applications such as HVAC and industrial maintenance
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
Single-block drywell calibrator with adjustable setpoints for temperature sensor calibration. Temperature range -25°C to 140°C with stability ±0.02°C at -25°C. Accepts two probes with 4 mm stem diameter. Suitable for field calibration of thermocouples, RTDs, and thermistors in industrial and laboratory settings
FLUKE
Single-block drywell calibrator with adjustable setpoints for temperature sensor calibration. Temperature range -25°C to 140°C with stability ±0.02°C at -25°C. Accepts two probes with 4 mm stem diameter. Suitable for field calibration of thermocouples, RTDs, and thermistors in industrial and laboratory settings