Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FLUKE CALIBRATION Single-Block Drywell Calibrator - Single-Block Drywell Calibrators with Adjustable Setpoints
FLUKE CALIBRATIONSingle-Block Drywell Calibrators with Adjustable Setpoints

FLUKE CALIBRATION Single-Block Drywell Calibrator

The FLUKE CALIBRATION Drywall Temperature Calibrator (MPN 9100S-D-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 14°F to 707°F (-10°C to 375°C). It offers stability of…

SKU 3G-OTH-178559

Also listed as: 9100SD156 · 9100S D 156

Brand
FLUKE CALIBRATION
Item
Single-Block Drywell Calibrator
Category
Single-Block Drywell Calibrators with Adjustable Setpoints
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FLUKE CALIBRATION
Manufacturer Part Number
9100S-D-156
Type
/-10°C to 375°C, For 1.6 mm Stem Dia
Stability
+/-0.05 °C at 0 °C
For Stem Diameter
1.6 mm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE CALIBRATION Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE CALIBRATION Drywall Temperature Calibrator (MPN 9100S-D-156) is a single-block drywell calibrator with adjustable setpoints, covering a range of 14°F to 707°F (-10°C to 375°C). It offers stability of +/-0.05 °C at 0 °C and is designed for stem diameters of 1.6 mm. This unit provides a compact solution for temperature calibration in industrial settings.

Frequently Asked Questions

What is the FLUKE CALIBRATION 9100S-D-156 drywell calibrator used for?

The FLUKE CALIBRATION 9100S-D-156 is a single-block drywell temperature calibrator used to verify and adjust temperature sensors and probes in industrial settings. It covers -10°C to 375°C with stability of +/-0.05 °C at 0 °C, making it suitable for calibration labs and maintenance departments.

What are the specifications of the FLUKE CALIBRATION 9100S-D-156?

The FLUKE CALIBRATION 9100S-D-156 drywell calibrator has a temperature range of -10°C to 375°C (14°F to 707°F), stability of +/-0.05 °C at 0 °C, and accepts probes with a 1.6 mm stem diameter. It is a single-block unit with adjustable setpoints, ideal for precise field calibration.

Where to buy the FLUKE CALIBRATION 9100S-D-156 worldwide?

3G Electric supplies the FLUKE CALIBRATION 9100S-D-156 drywell calibrator to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this precision temperature calibration instrument.

How to maintain a FLUKE CALIBRATION drywell calibrator?

To maintain the FLUKE CALIBRATION 9100S-D-156, keep the drywell insert clean and free of debris. Allow the unit to cool before cleaning. Periodically verify calibration against a reference standard. Store in a dry environment when not in use. Refer to the manufacturer's manual for detailed procedures.

Used in

Common applications for FLUKE CALIBRATION
Process control calibration — Fluke Calibration drywell calibrators (e.g., 9100S-D-156) for temperature sensor verification in chemical plants.
Pressure transmitter testing — Fluke Calibration pneumatic test pump kits (e.g., 700HPPK-NPT) for calibrating gauges in oil and gas facilities.
Hydraulic system maintenance — Fluke Calibration deadweight testers (e.g., P5510/14B-2700G) for pressure standard checks in hydraulic power units.
Temperature probe validation — Fluke Calibration secondary probes (e.g., 5615-12-P) for RTD calibration in pharmaceutical manufacturing.
Field service calibration — Fluke Calibration pneumatic comparison test pumps (e.g., 700HPM manifold) for on-site pressure calibration in utility plants.

FLUKE CALIBRATION Products

3G Electric supplies FLUKE CALIBRATION single-block drywell calibrators with adjustable setpoints. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -25°C to 140°C (-13°F to 284°F) with stability ±0.04°C at 140°C. Accepts stem diameters of 1/16 in. Suitable for verifying thermocouples, RTDs, and thermistors in HVAC, industrial process control, and building diagnostics
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 35°C to 350°C (95°F to 662°F) with stability of ±0.03°C at 50°C. Accommodates two probes with 6 mm stem diameter
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 95°F to 662°F (35°C to 350°C) with stability of ±0.03°C at 50°C. Accommodates up to six probes with 1/4 in stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range 95°F to 662°F (35°C to 350°C) with stability of ±0.03°C at 50°C. Accommodates up to six probes with 1/4 in stem diameter
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
FLUKE
This single-block drywell calibrator provides adjustable setpoints over a range of 95°F to 662°F (35°C to 350°C). It offers stability of ±0.03°C at 50°C and accepts probes with stem diameters up to 1/2 in. Used for calibrating temperature sensors such as thermocouples, RTDs, and thermistors in industrial process control and HVAC applications
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
FLUKE
Single-block drywell calibrator with adjustable setpoints for verifying and adjusting temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability of ±0.02°C at –25°C. Accommodates up to six probes with 1/4 in stem diameter
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability ±0.02°C at -25°C. Accommodates two 1/4-inch stem diameter probes
FLUKE
Single-block drywell calibrator with adjustable setpoints for field calibration of temperature sensors. Temperature range -13°F to 284°F / -25°C to 140°C with stability ±0.02°C at -25°C. Accommodates two 1/4-inch stem diameter probes

More from FLUKE CALIBRATION

View all FLUKE CALIBRATION parts
Single-block drywell calibrator with adjustable setpoints for temperature calibration of sensors and probes. Stability of ±0.05 °C at 0 °C. Accommodates stem diameter of 11.1 mm. Suitable for industrial and laboratory calibration tasks requiring precise temperature control
FLUKE CALIBRATION