Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FLUKE Infrared Thermometer: FLUKE-62 MAX, Avg/Difference/Max Temp/Min Temp - Standard Infrared Thermometers
FLUKEStandard Infrared Thermometers

FLUKE Infrared Thermometer: FLUKE-62 MAX, Avg/Difference/Max Temp/Min Temp

The FLUKE-62 MAX is a standard infrared thermometer from FLUKE with a mini body style and a backlit LCD display. It measures temperatures from -22°F up to 1202°F with an accuracy of ±1.5% of reading or ±3.0°F…

SKU 3G-OTH-178594

Also listed as: FLUKE62MAX · FLUKE 62 MAX · FLUKE-62-MAX

Brand
FLUKE
Item
Infrared Thermometer: FLUKE-62 MAX, Avg/Difference/Max Temp/Min Temp
Category
Standard Infrared Thermometers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FLUKE
Manufacturer Part Number
FLUKE-62 MAX
Type
Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
Features
Backlit Display
Standards
IEC 68-2-6
Alert Type
Sound
Accuracy °F
±1.5% of Reading or ±3.0° Whichever is Greater
Data Logging
Yes
Resolution °F
0.2°F
Max. Emissivity
1.00
Min. Emissivity
0.10
Body Style - NEW
Mini
Testing Functions
Difference
Temperature Alerts
High Temperature
Mounting Style - NEW
Tripod
Intrinsic Safety - NEW
Not Specified Intrinsically Safe
Includes Work Light - NEW
Work Light Included
Max. Temperature Measured
Up to 1202° F
Min. Temperature Measured
-22°
Digital Display Screen Type
LCD with Backlight
Calibration Certificate Type
Not Certified

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE-62 MAX is a standard infrared thermometer from FLUKE with a mini body style and a backlit LCD display. It measures temperatures from -22°F up to 1202°F with an accuracy of ±1.5% of reading or ±3.0°F, whichever is greater, and a resolution of 0.2°F. The device offers data logging, high-temperature alerts with sound, and difference testing functions, with adjustable emissivity from 0.10 to 1.00. It is tripod-mountable and complies with IEC 68-2-6 standards.

Frequently Asked Questions

What is the FLUKE-62 MAX infrared thermometer used for?

The FLUKE-62 MAX is a standard infrared thermometer for non-contact surface temperature measurement in industrial maintenance, HVAC, and electrical troubleshooting. It measures from -22°F to 1202°F with a backlit display, high-temperature sound alerts, and difference testing functions, making it suitable for spot-checking equipment and identifying hot spots.

What are the specifications of the FLUKE-62 MAX?

The FLUKE-62 MAX measures temperatures from -22°F to 1202°F with accuracy of ±1.5% of reading or ±3.0°F, whichever is greater, and resolution of 0.2°F. It features adjustable emissivity from 0.10 to 1.00, data logging, high-temperature sound alerts, a backlit LCD, tripod-mountable design, and complies with IEC 68-2-6 standards. It is not specified as intrinsically safe.

Where to buy the FLUKE-62 MAX worldwide?

The FLUKE-62 MAX is available to order through 3G Electric, a global industrial equipment distributor. We source and deliver this FLUKE infrared thermometer worldwide, handling full logistics, customs clearance, and delivery to your site. Contact 3G Electric for availability and lead time.

How to use the FLUKE-62 MAX for accurate temperature readings?

To use the FLUKE-62 MAX, aim at the target surface and pull the trigger. Adjust emissivity between 0.10 and 1.00 to match the material for accuracy. The device logs data and sounds an alert for high temperatures. For stable measurements, mount it on a tripod. Ensure the lens is clean and avoid reflective surfaces for best results.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE standard infrared thermometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FLUKE Infrared Thermometer: FLUKE-62 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: FLUKE-62 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE Infrared Thermometer: Fluke 64 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: Fluke 64 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE Infrared Thermometer: FLUKE-572-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, USB
FLUKE
FLUKE Infrared Thermometer: FLUKE-572-2, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, USB
FLUKE Infrared Thermometer: FLUKE-572-2/CWG, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: FLUKE-572-2/CWG, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE Infrared Thermometer: FLUKE-561, Difference/Max Temp/Min Temp, Adj @ 0.30 to 0.95, -40°
FLUKE
FLUKE Infrared Thermometer: FLUKE-561, Difference/Max Temp/Min Temp, Adj @ 0.30 to 0.95, -40°
FLUKE Infrared Thermometer: Fluke-568/NIST, Included, Avg/Difference/Max Temp/Min Temp, USB, -40°
FLUKE
FLUKE Infrared Thermometer: Fluke-568/NIST, Included, Avg/Difference/Max Temp/Min Temp, USB, -40°

More from FLUKE

View all FLUKE parts
FLUKE Infrared Thermometer: Fluke-566/NIST, Included, Avg/Difference/Max Temp/Min Temp, -40°
FLUKE
FLUKE Infrared Thermometer: Fluke-566/NIST, Included, Avg/Difference/Max Temp/Min Temp, -40°
FLUKE Infrared Thermometer: FLUKE-59 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE
FLUKE Infrared Thermometer: FLUKE-59 MAX +, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00
FLUKE Infrared Thermometer: FLUKE-566, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, -40°
FLUKE
FLUKE Infrared Thermometer: FLUKE-566, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, -40°
FLUKE Infrared Thermometer: FLK-TIS60+ 30HZ, Difference, Adj @ 0.10 to 1.00, Full Size Body, -4°
FLUKE
FLUKE Infrared Thermometer: FLK-TIS60+ 30HZ, Difference, Adj @ 0.10 to 1.00, Full Size Body, -4°
FLUKE Infrared Thermometer: FLUKE-59 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, Std
FLUKE
FLUKE Infrared Thermometer: FLUKE-59 MAX, Avg/Difference/Max Temp/Min Temp, Adj @ 0.10 to 1.00, Std