Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FLUKE Handheld Pressure Calibrator: Fluke-718Ex-300, Included, -12 psi – 300 psi - Standard Handheld Pressure Calibrators
FLUKEStandard Handheld Pressure Calibrators

FLUKE Handheld Pressure Calibrator: Fluke-718Ex-300, Included, -12 psi – 300 psi

The FLUKE Fluke-718Ex-300 is a standard handheld pressure calibrator from FLUKE, featuring intrinsic safety and a pressure measurement accuracy of 0.05% Full Scale. It measures pressure in bar and includes AC72 Test…

SKU 3G-OTH-178825

Also listed as: Fluke718Ex300 · Fluke 718Ex 300

Brand
FLUKE
Item
Handheld Pressure Calibrator: Fluke-718Ex-300, Included, -12 psi – 300 psi
Category
Standard Handheld Pressure Calibrators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FLUKE
Manufacturer Part Number
Fluke-718Ex-300
Type
Included, -12 psi – 300 psi, 0 V DC – 30 V DC
Includes
AC72 Test Clips
Intrinsic Safety
Yes
Pressure Measuring Units
bar
Pressure Measurement Accuracy
0.05% Full Scale

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FLUKE Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FLUKE Fluke-718Ex-300 is a standard handheld pressure calibrator from FLUKE, featuring intrinsic safety and a pressure measurement accuracy of 0.05% Full Scale. It measures pressure in bar and includes AC72 Test Clips. The unit covers a pressure range of -12 psi to 300 psi and a voltage range of 0 V DC to 30 V DC.

Frequently Asked Questions

What is the FLUKE Fluke-718Ex-300 handheld pressure calibrator used for?

The FLUKE Fluke-718Ex-300 is used for calibrating pressure instruments in hazardous environments, thanks to its intrinsic safety rating. It is ideal for plant engineers and maintenance technicians working in oil and gas, chemical, or industrial settings where explosive gases may be present.

What are the specifications of the FLUKE Fluke-718Ex-300?

The FLUKE Fluke-718Ex-300 measures pressure from -12 psi to 300 psi with an accuracy of 0.05% Full Scale, in bar units. It also measures 0 V DC to 30 V DC. The unit includes AC72 Test Clips and is intrinsically safe for use in hazardous areas.

Where to buy the FLUKE Fluke-718Ex-300 worldwide?

You can source the FLUKE Fluke-718Ex-300 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring the calibrator reaches your facility reliably.

How to select the right FLUKE handheld pressure calibrator for my application?

Select a FLUKE handheld pressure calibrator based on your required pressure range, accuracy, and safety needs. For hazardous environments, choose an intrinsically safe model like the Fluke-718Ex-300. Ensure the unit supports your preferred pressure units, such as bar, and includes necessary accessories like test clips.

Used in

Common applications for FLUKE
Industrial process calibration — Fluke FLK-729PRO 4M automatic pressure calibrator for verifying pressure transmitters and switches
Electrical maintenance — Fluke-77 IV digital multimeter for measuring AC/DC voltage and current in control panels
HVAC diagnostics — Fluke-59 MAX infrared thermometer for non-contact temperature measurement of ducts and equipment
Rotating equipment alignment — Fluke 832 NA laser shaft alignment tool for aligning pump and motor shafts
Temperature sensor calibration — Fluke 9144-E-P-156 drywell for calibrating RTDs and thermocouples in field metrology
Electrical safety testing — Fluke FTP-1 test probe for making voltage measurements in CAT III and CAT IV environments

FLUKE Products

3G Electric supplies FLUKE standard handheld pressure calibrators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FLUKE Handheld Pressure Calibrator: Fluke-718Ex-100, Included, -12 psi – 100 psi, 0 V DC – 30 V DC
FLUKE
FLUKE Handheld Pressure Calibrator: Fluke-718Ex-100, Included, -12 psi – 100 psi, 0 V DC – 30 V DC
FLUKE Handheld Pressure Calibrator: FLUKE-719 30G, HART, Included, -12 psi – 36 psi, 0 mA – 24 mA
FLUKE
FLUKE Handheld Pressure Calibrator: FLUKE-719 30G, HART, Included, -12 psi – 36 psi, 0 mA – 24 mA
FLUKE Handheld Pressure Calibrator: FLUKE-719 100G, HART, Included, -12 psi – 120 psi, 0 mA – 24 mA
FLUKE
FLUKE Handheld Pressure Calibrator: FLUKE-719 100G, HART, Included, -12 psi – 120 psi, 0 mA – 24 mA
FLUKE Handheld Pressure Calibrator: Fluke-718 30, Included, AC175 Alligator Clips/TL75 Test Leads
FLUKE
FLUKE Handheld Pressure Calibrator: Fluke-718 30, Included, AC175 Alligator Clips/TL75 Test Leads
Compact handheld pressure calibrator measuring pressure from -12 psi to 30 psi with 0.05% Full Scale accuracy and voltage from 0 V DC to 30 V DC. Includes test leads. NIST certified. Not intrinsically safe. Used for field calibration of pressure transmitters, switches, and gauges
FLUKE
Compact handheld pressure calibrator measuring pressure from -12 psi to 30 psi with 0.05% Full Scale accuracy and voltage from 0 V DC to 30 V DC. Includes test leads. NIST certified. Not intrinsically safe. Used for field calibration of pressure transmitters, switches, and gauges
FLUKE Handheld Pressure Calibrator: FLUKE-717-300G, Included, -12 psi – 300 psi, 0 V DC – 30 V DC
FLUKE
FLUKE Handheld Pressure Calibrator: FLUKE-717-300G, Included, -12 psi – 300 psi, 0 V DC – 30 V DC

More from FLUKE

View all FLUKE parts
Intrinsically safe handheld pressure calibrator with a pressure range of -12 psi to 30 psi and voltage measurement from 0 V DC to 30 V DC. Measures pressure in bar with an accuracy of 0.05% Full Scale. Includes TL75 test leads. Suitable for calibrating pressure instruments in hazardous environments
FLUKE
Intrinsically safe handheld pressure calibrator with a pressure range of -12 psi to 30 psi and voltage measurement from 0 V DC to 30 V DC. Measures pressure in bar with an accuracy of 0.05% Full Scale. Includes TL75 test leads. Suitable for calibrating pressure instruments in hazardous environments
Standard handheld pressure calibrator with HART communication protocol. Measures pressure from -12 psi to 300 psi with +/-0.025% accuracy. Includes carrying case. IP40 rated. Used for calibrating pressure transmitters, switches, and other process instruments in industrial environments
FLUKE
Standard handheld pressure calibrator with HART communication protocol. Measures pressure from -12 psi to 300 psi with +/-0.025% accuracy. Includes carrying case. IP40 rated. Used for calibrating pressure transmitters, switches, and other process instruments in industrial environments
Standard handheld pressure calibrator with HART communication protocol. Measures pressure from -12 psi to 30 psi with +/-0.025% accuracy. Includes current measurement from 0 mA to 24 mA and comes with alligator clips. Used for calibrating pressure instruments and transmitters in industrial process plants
FLUKE
Standard handheld pressure calibrator with HART communication protocol. Measures pressure from -12 psi to 30 psi with +/-0.025% accuracy. Includes current measurement from 0 mA to 24 mA and comes with alligator clips. Used for calibrating pressure instruments and transmitters in industrial process plants
The FLUKE-718-1G is a standard handheld pressure calibrator that measures pressure in psi with an accuracy of +/-0.025% Full Scale. It includes AC175 Alligator Clips and TL75 Test Leads. This unit is not rated for intrinsic safety. Typical applications include field calibration of pressure transmitters, switches, and gauges in industrial process plants, HVAC systems, and manufacturing facilities
FLUKE
The FLUKE-718-1G is a standard handheld pressure calibrator that measures pressure in psi with an accuracy of +/-0.025% Full Scale. It includes AC175 Alligator Clips and TL75 Test Leads. This unit is not rated for intrinsic safety. Typical applications include field calibration of pressure transmitters, switches, and gauges in industrial process plants, HVAC systems, and manufacturing facilities
The FLUKE-718-300G is a standard handheld pressure calibrator that measures pressure in mbar with an accuracy of +/-0.025% Full Scale. It includes AC175 Alligator Clips and TL75 Test Leads. This unit is not intrinsically safe. Typical applications include field calibration of pressure transmitters, switches, and gauges in industrial process plants, HVAC systems, and manufacturing facilities
FLUKE
The FLUKE-718-300G is a standard handheld pressure calibrator that measures pressure in mbar with an accuracy of +/-0.025% Full Scale. It includes AC175 Alligator Clips and TL75 Test Leads. This unit is not intrinsically safe. Typical applications include field calibration of pressure transmitters, switches, and gauges in industrial process plants, HVAC systems, and manufacturing facilities
Handheld pressure calibrator with HART communication protocol. Measures pressure from -14 psi to 1,500 psi and voltage from 0 V DC to 30 V DC with accuracy of +/-0.025% full scale. Includes soft case and test leads. Used for testing and calibrating pressure instruments and transmitters in industrial process environments
FLUKE
Handheld pressure calibrator with HART communication protocol. Measures pressure from -14 psi to 1,500 psi and voltage from 0 V DC to 30 V DC with accuracy of +/-0.025% full scale. Includes soft case and test leads. Used for testing and calibrating pressure instruments and transmitters in industrial process environments
Standard handheld pressure calibrator with HART communication protocol. Measures pressure from -12 psi to 150 psi with accuracy of +/-0.025%. Includes fluid trap for wet applications. IP40 rated. Used for calibrating pressure transmitters and gauges in industrial process environments
FLUKE
Standard handheld pressure calibrator with HART communication protocol. Measures pressure from -12 psi to 150 psi with accuracy of +/-0.025%. Includes fluid trap for wet applications. IP40 rated. Used for calibrating pressure transmitters and gauges in industrial process environments
FLUKE Handheld Pressure Calibrator: FLUKE 718 100G, Included, AC175 Alligator Clips/TL75 Test Leads
FLUKE
FLUKE Handheld Pressure Calibrator: FLUKE 718 100G, Included, AC175 Alligator Clips/TL75 Test Leads