Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

FBR FNDP 70/M TC SA - Burners & Combustion
FBRBurners & Combustion

FBR FNDP 70/M TC SA

FBR FNDP 70/M TC is a heavy oil burner for industrial heating applications, offering sliding or modulating combustion control with maximum thermal output of 10000 kcal/h and flow capacity of 1020 kg/h. The unit…

SKU 3G-FBR-00286

Brand
FBR
Item
FNDP 70/M TC SA
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

FBR
Weight
700 kg
stage
Sliding or modulating
fuel type
Heavy oil
nozzle mm
250
fan motor w
30
power kw max
11628
power kw min
1299
flow kg h max
1020
flow kg h min
114
ip protection
IP40
noisiness dba
82-83
pump motor kw
5.5
electrical supply
3
power supply info
1N~230V - 50Hz
current absorption a
4.35
thermal power mcal h
1117/3400-10000
nominal electric power w
9
max combustion air temp c
60

Datasheet Content

HEAVY-OIL BURNERS_FNDP SERIES SK072023_B_gb FNDP฀750-1000/M MECHANICAL MODULATION Heavy฀oil฀burners฀at฀2฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if ฀฀equipped฀with฀modulation฀kit฀and ฀ probe. Fan฀at฀ high฀pressurization,฀high฀efficiency฀combustion฀head฀with฀adjustment฀and฀฀ high฀flame฀stability,฀pump,฀multistage฀preheating฀tank฀and฀degaser฀skid.฀Suitable฀for฀heavy฀oil฀up฀to฀50°E฀to฀50°C฀and฀for฀BTZ฀ heavy฀oil. Rational฀disposal฀of฀components฀with฀easy฀accessibility฀for฀calibration฀and฀maintenance฀operations. The฀adoption฀of฀strong฀metal฀components฀makes฀the฀burner฀durable฀also฀in฀heavy฀duty฀conditions. Burners฀are฀supplied฀with฀nozzle,฀gasket฀for฀installation฀on฀boiler,฀flexible฀hoses,฀line฀filter and degaser tank. Pump฀skid FNDP฀ 750-1000/M HEAVY-OIL BURNERS_FNDP SERIES SK072023_B_gb TECHNICAL DATA MODEL FNDP 750/M FNDP 1000/M Thermal฀power฀min.1°st.฀/฀min.2°st.฀-฀max.2°st.฀* [Mcal/h] 1117/3400-7500 1117/3400-10000 Thermal฀power฀min.1°st.฀/฀min.2°st.฀-฀max.2°st.฀* [kW] 1299/3953-8721 1299/3953-11628 HEAVY-OIL฀flow฀min.1°st.฀/฀min.2°st.฀-฀max.2°st.฀* [kg/h] 114/347-765 114/347-1020 Fuel:฀Heavy-oil฀5°-50°E฀a฀50°C Intermittent฀working฀operation฀(min,฀1฀stop฀every฀24฀hours)฀two฀stages฀progressive฀or฀modulating Enviromental฀conditions฀operation/storage -15...+40°C฀/฀-20...+70°C฀,relative฀humidity฀max.฀80% Max฀temperature฀combustion฀air [°C] 60 60 Total nominal฀electric฀power (burner + skid group) [kW] 80 100 Fan฀motor [kW] 22 30 Pump฀motor [kW] 3 5.5 Nominal฀electric฀power฀skid฀group [kW] 58 69 Resistances [kW] 54 63 Fan฀motor฀absorption [A] 43 56 Pump฀motor฀absorption [A] 6.5 11.7 Resistances฀absorption [A] 240 273 Absorption฀burner฀auxiliary฀circuit [A] 4 4 Absorption฀skid฀group฀auxiliary฀circuit [A] 0.5 0.5 Power฀supply 3~400V,฀1N~230V฀-฀50Hz Burner฀degree฀of฀electric฀protection IP40 IP40 Skid฀group฀degree฀of฀electric฀protection IP40 IP40 Burner฀weight [kg] 590 700 Skid฀group฀weight [kg] 336 366 *฀Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level). FIRING RATES [mbar] 40 35 30 25 20 15 10 5 FNDP 750/M FNDP 1000/M 0 -5 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 [kW] Fig. 1 X฀=฀Thermal฀power฀Y฀=฀Pression฀in฀the฀combustion฀chamber The฀firing฀rates฀has฀been฀obtained฀based฀on฀test฀boilers฀in฀accordance฀with฀EN267฀standards฀and฀are฀indicative฀of฀matching฀the฀burner฀to฀the฀boiler.฀For฀the฀correct฀฀ operation฀of฀the฀burner,฀combustion฀chamber฀dimensions฀must฀be฀in฀accordance฀with฀current฀regulation.฀In฀case฀of฀non-compliance,฀contact฀the฀manufacturer. FNDP฀ 750-1000/M HEAVY-OIL BURNERS_FNDP SERIES SK072023_B_gb DIMENSIONS฀[mm] Fig. 2 Dimensions MODEL A B C D E F G TL FNDP 750/M 600 634 845 439 1453 832 22 685 FNDP 1000/M 600 634 845 459 1453 832 22 685 BOILER PLATE The dimensions of the boiler plate (threaded holes or studs) must be as indicated in the drawing. MODEL M N min N* N Max L min L max FNDP 750/M mm M16 707 778 778 460 540 FNDP 1000/M mm M16 707 778 778 510 540 FNDP฀ 750-1000/M HEAVY-OIL BURNERS_FNDP SERIES SK072023_B_gb PUMP฀SKID:฀DIMENSIONS฀(mm) 0 Fig. 3 Pump฀skid฀dimensions MODEL A B C D E F G H I L M FNDP 750/M 1207 1466 1130 183 331 258 245 173 1013 1485 961 FNDP 1000/M 1207 1466 1130 183 331 258 245 173 1013 1485 961 FNDP฀ 750-1000/M HEAVY-OIL BURNERS_FNDP SERIES SK072023_B_gb PRODUCT SPECIFICATION SHORT DESCRIPTION Heavy oil burners at 2 stages progressive (hi-low flame) or PID fully modulating if equipped with modulation kit and probe. Available versions for heavy oil up to 50°E to 50°C and ecological heavy oil BTZ (low sulfur oil). DETAILED฀SPECIFICATION Heavy฀oil฀burners฀from฀5฀to฀50°E฀at฀50°C,฀2฀stages฀progressive฀(hi-low฀flame),฀with฀possibility฀of฀modulating฀working฀(PID฀fully฀ modulating฀ with฀optional฀modulation฀kit฀and฀probe).฀The฀burner฀is฀composed฀by: • Burner฀frame฀made฀of฀steel฀completed฀by฀specific฀boiler฀plate; • Centrifugal฀fan฀at฀high฀pressurization฀with฀reverse฀curved฀blades฀at฀low฀noisiness; • Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability฀equipped฀with฀steel฀blast฀tube฀and฀steel฀฀ flame฀disc; • Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier; • Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler/furnace; • PID฀regulators฀for฀the฀control฀of฀fuel฀heaters; • Mechanical฀control฀system฀for฀controlling฀and฀command฀the฀burner; • Photoresistance฀for฀flame฀detection; • Three-phase฀power฀supply; • Fan฀motor฀start-up฀made฀by฀delta/star฀system; • IP40฀electric฀protection฀level; • Safety฀air฀pressure฀switch฀to฀stop฀the฀burner฀in฀case฀of฀failed฀or฀anomalous฀fan฀operation; • Maximum฀oil฀pressure฀switch฀to฀stop฀the฀burner฀in฀case฀of฀the฀oil฀pressure฀on฀the฀return฀is฀higher฀then฀the฀set฀point฀value; • Servomotor฀for฀air฀shutter฀and฀for฀the฀heavy฀oil฀adjust; • Mobile฀shutter฀with฀total฀closure฀when฀idle฀for฀minimize฀the฀energetic฀losses฀related฀at฀boiler฀cooling; • Heavy฀oil฀gear฀pump฀operated฀by฀specific฀electric฀motor; • Thermocouples฀for฀detecting฀the฀oil฀temperature; • Button฀for฀the฀manual฀tank฀load; • Multistage฀pre-heating฀tank฀with฀specific฀flanged฀heaters฀at฀low฀density฀(anticracking฀and฀antigas); • Resistances฀(always฀on)฀for฀pump,฀nozzle฀and฀fuel฀valve; • Pressure฀manometer฀on฀inlet฀pump; • Nozzle฀assembly฀with฀magnet฀to฀control฀inlet/return฀needle฀nozzle; • Double฀filter฀between฀pump฀and฀nozzle; • Set฀up฀for฀the฀additional฀specific฀kit฀that฀transforms฀burner฀operation฀as฀modulating฀i.e.the฀modulating฀kit฀allows฀to฀supply฀any฀ ฀฀power฀between฀the฀minimum฀and฀maximum฀value฀based฀on฀instantaneous฀loading฀request. CONFORMING TO: • CE฀rules; • 2014/30/UE฀Directive฀E.M.C.; • 2014/35/UE฀Directive฀L.V.; • 2006/42/CE฀-฀2006/42/EG฀-฀2006/42/EC฀Directive฀M.D.; • Reference฀rules:฀EN267฀(liquid฀fuel)฀-฀EN746-2฀(industrial฀thermoprocessing฀equipment) STANDARD EQUIPMENT • Degaser tank • Flexible pipes for connection • Line filter • Isomart gasket • Nozzle • Flange with insulating gasket • Burner nameplate • Warranty • Instruction handbook for installation, use and maintenance FNDP฀ 750-1000/M HEAVY-OIL BURNERS_FNDP SERIES SK072023_B_gb OPTIONAL • Power฀modulating฀kits฀for฀temperatures; • Power฀modulating฀kits฀for฀pressures; • Kit฀for฀input฀4-20mA฀/฀0-10Vdc; • Temperature฀probe฀0°C-400°C฀(PT฀100฀฀a฀0°฀C); • Temperature฀probe฀0°C-350°C฀(J฀probe); • Temperature฀probe฀0°C-1200°C฀(K฀probe); • Pressure฀probe฀0-3฀bar,฀0-6฀bar.฀0-16฀bar,฀0-20฀bar,฀0-30฀bar; • Noise฀protection The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FNDP฀ 750-1000/M
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR FNDP 70/M TC is a heavy oil burner for industrial heating applications, offering sliding or modulating combustion control with maximum thermal output of 10000 kcal/h and flow capacity of 1020 kg/h. The unit delivers flexible two-stage operation suitable for large-scale heating installations.

Frequently Asked Questions

What is the FBR FNDP 70/M TC SA heavy oil burner used for?

The FBR FNDP 70/M TC SA is a heavy oil burner designed for industrial heating applications such as large boilers and furnaces. It delivers two-stage progressive or fully modulating combustion control, making it suitable for installations requiring precise thermal output up to 10000 kcal/h and flow capacity of 1020 kg/h.

What are the specifications of the FBR FNDP 70/M TC SA burner?

The FBR FNDP 70/M TC SA burner has a thermal power range of 1299 kW to 11628 kW, heavy oil flow from 114 kg/h to 1020 kg/h, and a fan motor rated at 30 kW. It operates on 3~400V, 1N~230V, 50 Hz power supply, with IP40 protection and a total weight of 700 kg.

Where to buy the FBR FNDP 70/M TC SA burner in Singapore?

3G Electric supplies the FBR FNDP 70/M TC SA heavy oil burner to Singapore. We handle sourcing, logistics, customs clearance, and local delivery. Contact our team for pricing and lead time on this industrial burner for your heating project.

How to install and maintain the FBR FNDP 70/M TC SA burner?

Installation requires mounting the burner on the boiler using the supplied gasket and flexible hoses, with proper electrical connection to 3~400V supply. Maintenance includes periodic cleaning of the nozzle, line filter, and degaser tank, plus calibration of the combustion head for optimal flame stability as per FBR guidelines.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FNDP 70/M TL SA
FBR
FNDP 70/M TL SA
FNDP 100/M TC SA
FBR
FNDP 100/M TC SA
FNDP 70/2 TC SI
FBR
FNDP 70/2 TC SI
FNDP 100/M TL SA
FBR
FNDP 100/M TL SA
FNDP 45/2 TC SI
FBR
FNDP 45/2 TC SI
FNDP 70/2 TL SI
FBR
FNDP 70/2 TL SI

More from FBR

View all FBR parts
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC