Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASCO 105ES-65N-208.4 Calibration Gas - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 105ES-65N-208.4 Calibration Gas

The GASCO Calibration Gas: Nitrogen is a +/-5% accuracy calibration gas for portable gas detectors, compatible with all OEM gas detectors. It contains an Ethanol 208.4 ppm gas mixture with a Nitrogen background gas…

SKU 3G-OTH-551006

Also listed as: 105ES65N2084 · 105ES 65N 208 4 · 105ES-65N-208-4

Brand
GASCO
Item
105ES-65N-208.4 Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

GASCO
Manufacturer Part Number
105ES-65N-208.4
Type
+/-5% Accuracy, C2H6O, Calibration Gas
Gas Mixture
Ethanol 208.4 ppm
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen
Cylinder Capacity
105 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen is a +/-5% accuracy calibration gas for portable gas detectors, compatible with all OEM gas detectors. It contains an Ethanol 208.4 ppm gas mixture with a Nitrogen background gas, supplied in a 105 L cylinder (MPN 105ES-65N-208.4).

Frequently Asked Questions

What is GASCO calibration gas with ethanol used for?

GASCO calibration gas with ethanol 208.4 ppm in nitrogen is used to calibrate portable gas detectors from all OEMs. It verifies sensor accuracy for ethanol detection in industrial safety applications, such as chemical plants and laboratories, ensuring reliable readings.

What are the specifications of GASCO 105ES-65N-208.4?

The GASCO 105ES-65N-208.4 calibration gas contains ethanol at 208.4 ppm in a nitrogen background, with +/-5% accuracy. It comes in a 105 L cylinder and is compatible with all OEM gas detectors. The background gas is nitrogen.

Where to buy GASCO calibration gas in worldwide?

3G Electric supplies GASCO calibration gas worldwide. We handle full logistics, customs clearance, and delivery to your facility. As a global industrial solutions provider, we source and deliver genuine GASCO calibration gases for portable gas detectors to any location.

How to use GASCO calibration gas for gas detectors?

Attach the GASCO cylinder regulator to the 105 L cylinder, connect to the gas detector's calibration port, and flow the ethanol-nitrogen mixture at the detector's specified rate. Follow the detector manufacturer's calibration procedure. Store cylinders upright in a ventilated area.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
This calibration gas cylinder contains a propane mixture at 40% LEL (8,400 ppm) in a background of air, with +/-2% accuracy. The 105 L cylinder is used to verify and adjust the response of portable gas detectors to combustible gas hazards
GASCO
This calibration gas cylinder contains a propane mixture at 40% LEL (8,400 ppm) in a background of air, with +/-2% accuracy. The 105 L cylinder is used to verify and adjust the response of portable gas detectors to combustible gas hazards
Refillable calibration gas mixture with +/-5% accuracy, containing hexane (10% LEL) 0.11%, carbon monoxide, hydrogen sulfide, nitrogen, and oxygen in air. Used for verifying and adjusting the response of portable gas detectors in industrial environments where combustible and toxic gas monitoring is required
GASCO
Refillable calibration gas mixture with +/-5% accuracy, containing hexane (10% LEL) 0.11%, carbon monoxide, hydrogen sulfide, nitrogen, and oxygen in air. Used for verifying and adjusting the response of portable gas detectors in industrial environments where combustible and toxic gas monitoring is required
Calibration gas cylinder containing 200 ppm carbon dioxide with air background, 105 L capacity, and +/-2% accuracy. Used to verify and adjust the accuracy of portable and fixed gas detectors in industrial safety applications such as refineries, chemical plants, and confined spaces
GASCO
Calibration gas cylinder containing 200 ppm carbon dioxide with air background, 105 L capacity, and +/-2% accuracy. Used to verify and adjust the accuracy of portable and fixed gas detectors in industrial safety applications such as refineries, chemical plants, and confined spaces
Calibration gas cylinder containing Benzene 1 ppm in an air background, with a 105 L capacity and +/-5% accuracy. Used for field or bench calibration of portable gas detectors to verify and adjust sensor response
GASCO
Calibration gas cylinder containing Benzene 1 ppm in an air background, with a 105 L capacity and +/-5% accuracy. Used for field or bench calibration of portable gas detectors to verify and adjust sensor response
This calibration gas is a mixture of 12% oxygen in nitrogen with hydrogen sulfide, formulated for use with all OEM gas detectors. The 105 L cylinder provides a supply for routine calibration of portable gas detection instruments in industrial safety applications. Accuracy is ±2%
GASCO
This calibration gas is a mixture of 12% oxygen in nitrogen with hydrogen sulfide, formulated for use with all OEM gas detectors. The 105 L cylinder provides a supply for routine calibration of portable gas detection instruments in industrial safety applications. Accuracy is ±2%
Calibration gas cylinder containing propane (0.33% by volume, equivalent to 15.71% LEL) in a background of air. Accuracy is ±2%. Cylinder capacity is 105 L. Used for calibration of portable gas detectors in industrial safety applications
GASCO
Calibration gas cylinder containing propane (0.33% by volume, equivalent to 15.71% LEL) in a background of air. Accuracy is ±2%. Cylinder capacity is 105 L. Used for calibration of portable gas detectors in industrial safety applications
This calibration gas cylinder contains 485 ppm methane in air, with +/-2% accuracy, and a 105 L capacity. It is used for routine bump testing and calibration of portable gas detectors from all OEMs, verifying sensor accuracy and response to combustible gas hazards
GASCO
This calibration gas cylinder contains 485 ppm methane in air, with +/-2% accuracy, and a 105 L capacity. It is used for routine bump testing and calibration of portable gas detectors from all OEMs, verifying sensor accuracy and response to combustible gas hazards
Calibration gas mixture of 1.5% oxygen in nitrogen, with +/-2% accuracy, supplied in a 105 L cylinder. Used to verify the accuracy and alarm set points of portable gas detectors that monitor oxygen levels, supporting confined-space entry and industrial safety applications
GASCO
Calibration gas mixture of 1.5% oxygen in nitrogen, with +/-2% accuracy, supplied in a 105 L cylinder. Used to verify the accuracy and alarm set points of portable gas detectors that monitor oxygen levels, supporting confined-space entry and industrial safety applications