Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASCO 17L-333-15 Disposable Calibration Gas, 15% Oxygen in Nitrogen, CGA 600 - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 17L-333-15 Disposable Calibration Gas, 15% Oxygen in Nitrogen, CGA 600

The GASCO Calibration Gas: Nitrogen (MPN 17L-333-15) is a disposable calibration gas for all OEM gas detectors, featuring a CGA 600 connection and a gas mixture of Oxygen 15% with a background gas of Nitrogen. It…

SKU 3G-OTH-549402

Also listed as: 17L33315 · 17L 333 15

Brand
GASCO
Item
17L-333-15 Disposable Calibration Gas, 15% Oxygen in Nitrogen, CGA 600
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

GASCO
Manufacturer Part Number
17L-333-15
Type
Disposable, +/-5% Accuracy, C6H14/O2, Calibration Gas, CGA 600
CGA Number
CGA 600
Gas Mixture
Oxygen 15%
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen (MPN 17L-333-15) is a disposable calibration gas for all OEM gas detectors, featuring a CGA 600 connection and a gas mixture of Oxygen 15% with a background gas of Nitrogen. It offers +/-5% accuracy and is supplied as a C6H14/O2 calibration gas.

Frequently Asked Questions

What is GASCO Calibration Gas 17L-333-15 used for?

This disposable calibration gas is used to verify and adjust the accuracy of all OEM gas detectors. It contains a mixture of 15% oxygen in nitrogen, with +/-5% accuracy, ensuring reliable sensor response for safety monitoring in industrial environments.

What are the specifications of GASCO Calibration Gas 17L-333-15?

The GASCO 17L-333-15 is a disposable calibration gas with a CGA 600 connection. It contains a gas mixture of 15% oxygen (C6H14/O2) in nitrogen background gas, offering +/-5% accuracy. It is designed for use with all OEM gas detectors.

Where to buy GASCO Calibration Gas 17L-333-15 worldwide?

3G Electric supplies the GASCO 17L-333-15 calibration gas to customers worldwide. We handle full logistics, customs clearance, and delivery, ensuring you receive the correct gas mixture for your OEM gas detectors, regardless of your location.

How to use GASCO Calibration Gas 17L-333-15 for detector calibration?

Attach the CGA 600 regulator to the disposable cylinder, then connect to your gas detector's inlet. Follow the detector manufacturer's calibration procedure, applying the 15% oxygen mixture at the specified flow rate. Dispose of the cylinder after use per local regulations.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas cylinder containing methane at 0.4% (8% LEL) in an air background, with ±5% accuracy. Designed for verifying and calibrating portable gas detectors from all OEMs. Suitable for routine sensor performance checks in industrial safety applications
GASCO
Disposable calibration gas cylinder containing methane at 0.4% (8% LEL) in an air background, with ±5% accuracy. Designed for verifying and calibrating portable gas detectors from all OEMs. Suitable for routine sensor performance checks in industrial safety applications
Disposable calibration gas cylinder containing 3.5% Carbon Dioxide in nitrogen with +/-5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify sensor response and accuracy of gas detection equipment
GASCO
Disposable calibration gas cylinder containing 3.5% Carbon Dioxide in nitrogen with +/-5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify sensor response and accuracy of gas detection equipment
Disposable calibration gas mixture containing 20 ppm hydrogen cyanide (HCN) in nitrogen, with ±5% accuracy. Designed for calibrating all OEM gas detectors that sense hydrogen cyanide, verifying sensor accuracy and response before use in industrial safety applications such as chemical processing, mining, and firefighting
GASCO
Disposable calibration gas mixture containing 20 ppm hydrogen cyanide (HCN) in nitrogen, with ±5% accuracy. Designed for calibrating all OEM gas detectors that sense hydrogen cyanide, verifying sensor accuracy and response before use in industrial safety applications such as chemical processing, mining, and firefighting
Calibration gas cylinder containing methane at 47 ppm in an air background, with +/-5% accuracy and 105 L capacity. Used for field or bench calibration of portable gas detectors to verify response to combustible gas hazards
GASCO
Calibration gas cylinder containing methane at 47 ppm in an air background, with +/-5% accuracy and 105 L capacity. Used for field or bench calibration of portable gas detectors to verify response to combustible gas hazards
Disposable calibration gas mixture for verifying and calibrating portable gas detectors. Contains propane at 11% LEL (2,300 ppm) with +/-5% accuracy and a background gas of air. Compatible with all OEM gas detectors for routine field or bench calibration
GASCO
Disposable calibration gas mixture for verifying and calibrating portable gas detectors. Contains propane at 11% LEL (2,300 ppm) with +/-5% accuracy and a background gas of air. Compatible with all OEM gas detectors for routine field or bench calibration
Calibration gas mixture containing 1% carbon dioxide balanced in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder. Used for calibrating portable gas detectors that measure carbon dioxide, ensuring accurate sensor response in industrial safety applications
GASCO
Calibration gas mixture containing 1% carbon dioxide balanced in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder. Used for calibrating portable gas detectors that measure carbon dioxide, ensuring accurate sensor response in industrial safety applications
Disposable calibration gas cylinder containing 50 ppm carbon monoxide in nitrogen background gas. Accuracy ±5%. For use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 50 ppm carbon monoxide in nitrogen background gas. Accuracy ±5%. For use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
Calibration gas mixture containing 45 ppm carbon monoxide in nitrogen background gas, supplied in a 105 L cylinder. Accuracy is ±5%. Used to verify and adjust the response of portable gas detectors to carbon monoxide in industrial safety applications
GASCO
Calibration gas mixture containing 45 ppm carbon monoxide in nitrogen background gas, supplied in a 105 L cylinder. Accuracy is ±5%. Used to verify and adjust the response of portable gas detectors to carbon monoxide in industrial safety applications