Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASCO 34L-473-18 Disposable Calibration Gas - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO 34L-473-18 Disposable Calibration Gas

The GASCO Calibration Gas: Nitrogen (MPN 34L-473-18) is a disposable calibration gas for all OEM gas detectors, featuring a mixture of Carbon Monoxide 50 ppm with a background gas of Nitrogen and +/-5% accuracy.

SKU 3G-OTH-549008

Also listed as: 34L47318 · 34L 473 18

Brand
GASCO
Item
34L-473-18 Disposable Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

GASCO
Manufacturer Part Number
34L-473-18
Type
Disposable, +/-5% Accuracy, C3H8/CO/H2S/O2, Calibration Gas
Gas Mixture
Carbon Monoxide 50 ppm
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen (MPN 34L-473-18) is a disposable calibration gas for all OEM gas detectors, featuring a mixture of Carbon Monoxide 50 ppm with a background gas of Nitrogen and +/-5% accuracy.

Frequently Asked Questions

What is GASCO Calibration Gas 34L-473-18 used for?

This disposable calibration gas is used to verify and adjust the accuracy of portable gas detectors from all OEMs. It contains 50 ppm carbon monoxide in nitrogen, ensuring sensors respond correctly to hazardous gas levels in industrial safety applications.

What are the specifications of GASCO Calibration Gas 34L-473-18?

The GASCO 34L-473-18 is a disposable calibration gas with a mixture of 50 ppm carbon monoxide in nitrogen background gas. It offers +/-5% accuracy and is designed for use with all OEM gas detectors. The manufacturer part number is 34L-473-18.

Where to buy GASCO Calibration Gas 34L-473-18 worldwide?

3G Electric supplies GASCO calibration gas 34L-473-18 to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this disposable calibration gas for portable gas detectors.

How to use GASCO Calibration Gas 34L-473-18 for detector calibration?

Attach the disposable cylinder to your gas detector's calibration adapter, following the detector manufacturer's instructions. Apply the gas at the specified flow rate, typically 0.5 L/min, and allow the sensor to stabilize before adjusting readings. Always use in a well-ventilated area.

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
This calibration gas cylinder contains 2.27% methane (45.4% LEL) in air with +/-2% accuracy. The 105 L cylinder is used to verify and adjust the response of portable gas detectors from all OEMs in industrial safety monitoring applications
GASCO
This calibration gas cylinder contains 2.27% methane (45.4% LEL) in air with +/-2% accuracy. The 105 L cylinder is used to verify and adjust the response of portable gas detectors from all OEMs in industrial safety monitoring applications
Disposable calibration gas cylinder containing 25% carbon dioxide balanced with nitrogen, with +/-5% accuracy. Designed for use with all OEM gas detectors to verify sensor performance in industrial safety applications. Single-use, non-refillable cylinder provides a reliable reference for calibration
GASCO
Disposable calibration gas cylinder containing 25% carbon dioxide balanced with nitrogen, with +/-5% accuracy. Designed for use with all OEM gas detectors to verify sensor performance in industrial safety applications. Single-use, non-refillable cylinder provides a reliable reference for calibration
Disposable calibration gas cylinder containing 2.5 ppm ethylene in an air background, with ±5% accuracy. Used for field or bench calibration of portable gas detectors to verify sensor response for ethylene detection
GASCO
Disposable calibration gas cylinder containing 2.5 ppm ethylene in an air background, with ±5% accuracy. Used for field or bench calibration of portable gas detectors to verify sensor response for ethylene detection
Calibration gas mixture containing 5,000 ppm carbon dioxide with nitrogen balance, supplied in a 105 L cylinder. Certified to +/-2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust sensor response in industrial safety applications such as confined space entry and area monitoring
GASCO
Calibration gas mixture containing 5,000 ppm carbon dioxide with nitrogen balance, supplied in a 105 L cylinder. Certified to +/-2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust sensor response in industrial safety applications such as confined space entry and area monitoring
Disposable calibration gas cylinder containing 950 ppm carbon monoxide in nitrogen background gas. Provides ±5% accuracy for verifying and adjusting portable gas detector response in industrial safety applications such as confined-space entry and compliance testing
GASCO
Disposable calibration gas cylinder containing 950 ppm carbon monoxide in nitrogen background gas. Provides ±5% accuracy for verifying and adjusting portable gas detector response in industrial safety applications such as confined-space entry and compliance testing
Calibration gas mixture of 50 ppm carbon monoxide in an air background, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify sensor response. Suitable for routine calibration checks in industrial safety applications
GASCO
Calibration gas mixture of 50 ppm carbon monoxide in an air background, with +/-5% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify sensor response. Suitable for routine calibration checks in industrial safety applications
Disposable calibration gas cylinder containing 0.4% butane in nitrogen balance, with ±5% accuracy and CGA 600 connection. Used to verify and adjust the response of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 0.4% butane in nitrogen balance, with ±5% accuracy and CGA 600 connection. Used to verify and adjust the response of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Calibration gas mixture containing 1,000 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder. Designed for calibrating portable gas detectors from all OEMs, with +/-2% accuracy. Used to verify CO sensor performance in industrial safety applications
GASCO
Calibration gas mixture containing 1,000 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder. Designed for calibrating portable gas detectors from all OEMs, with +/-2% accuracy. Used to verify CO sensor performance in industrial safety applications