Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
GASCO Calibration Gas: Toluene 150 ppm in Air, 105 L Cylinder - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Calibration Gas: Toluene 150 ppm in Air, 105 L Cylinder

The GASCO Calibration Gas: Air is a +/-5% accuracy calibration gas cylinder containing a mixture of Toluene 150 ppm in a background of air, with a 105 L cylinder capacity. Designed for use with all OEM gas detectors…

SKU 3G-OTH-550438

Brand
GASCO
Item
Calibration Gas: Toluene 150 ppm in Air, 105 L Cylinder
Part Number
X02AI99CR1500L7
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

GASCO
Manufacturer Part Number
X02AI99CR1500L7
Type
+/-5% Accuracy, C7H8, Calibration Gas, Cylinder
Gas Mixture
Toluene 150 ppm
For Use With
All OEM Gas Detectors
Background Gas
Air
Cylinder Capacity
105 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Air is a +/-5% accuracy calibration gas cylinder containing a mixture of Toluene 150 ppm in a background of air, with a 105 L cylinder capacity. Designed for use with all OEM gas detectors, this C7H8 calibration gas (MPN X02AI99CR1500L7) provides a verified reference for portable gas detector calibration.

Frequently Asked Questions

What is GASCO calibration gas used for?

GASCO calibration gas is used to verify and calibrate portable gas detectors from all OEMs. The Toluene 150 ppm mixture in air provides a known reference concentration, ensuring your detector reads accurately for worker safety in industrial environments.

What are the specifications of GASCO calibration gas X02AI99CR1500L7?

This GASCO cylinder contains Toluene 150 ppm in a background of air, with +/-5% accuracy and a 105 L capacity. It is designed for use with all OEM gas detectors and carries MPN X02AI99CR1500L7.

Where to buy GASCO calibration gas worldwide?

3G Electric supplies GASCO calibration gas worldwide, handling full logistics and customs clearance. We source genuine GASCO cylinders like the X02AI99CR1500L7 and deliver to your facility, ensuring you receive the correct gas mixture for your detector calibration needs.

How to use GASCO calibration gas for portable gas detectors?

Attach the GASCO cylinder regulator to the cylinder valve, connect to your detector's calibration port, and follow the detector manufacturer's calibration procedure. Apply the gas at the specified flow rate until readings stabilise, then adjust the detector to match the 150 ppm Toluene concentration.

Not sure this is the right part? Photo-identify it

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from GASCO

View all GASCO parts
Disposable calibration gas cylinder containing pentane at 0.3% concentration (21.4% LEL) in air background. Accuracy ±5%. Used for verifying and adjusting the response of portable gas detectors in industrial safety applications such as combustible gas monitoring
GASCO
Disposable calibration gas cylinder containing pentane at 0.3% concentration (21.4% LEL) in air background. Accuracy ±5%. Used for verifying and adjusting the response of portable gas detectors in industrial safety applications such as combustible gas monitoring
Disposable calibration gas cylinder containing 6 ppm sulfur dioxide in air, with ±5% accuracy and 58 L capacity. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 6 ppm sulfur dioxide in air, with ±5% accuracy and 58 L capacity. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Disposable calibration gas cylinder containing 3000 ppm hydrogen in air background gas. Accuracy ±5%. 103 L capacity. For use with portable gas detectors to verify sensor response and adjust readings
GASCO
Disposable calibration gas cylinder containing 3000 ppm hydrogen in air background gas. Accuracy ±5%. 103 L capacity. For use with portable gas detectors to verify sensor response and adjust readings
Disposable calibration gas cylinder containing 90 ppm methane in nitrogen with ±5% accuracy. Designed for use with portable gas detectors from all OEMs. Fitted with a CGA 600 connection
GASCO
Disposable calibration gas cylinder containing 90 ppm methane in nitrogen with ±5% accuracy. Designed for use with portable gas detectors from all OEMs. Fitted with a CGA 600 connection
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide
GASCO
Calibration gas mixture of 225 ppm carbon monoxide in nitrogen, supplied in a 105 L cylinder with ±2% accuracy. Used for calibrating portable gas detectors from all OEM manufacturers to verify sensor response to carbon monoxide
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
GASCO
Calibration gas mixture containing 515 ppm carbon monoxide in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response to CO hazards
Calibration gas mixture containing 20.5% oxygen balanced with nitrogen, certified to ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
GASCO
Calibration gas mixture containing 20.5% oxygen balanced with nitrogen, certified to ±2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors to verify and adjust sensor response. Suitable for routine calibration in industrial safety applications
Calibration gas mixture containing 19% oxygen with nitrogen balance, supplied in a 105-liter cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust detector response in industrial safety applications
GASCO
Calibration gas mixture containing 19% oxygen with nitrogen balance, supplied in a 105-liter cylinder. Certified to ±2% accuracy for use with portable gas detectors from all OEMs. Used to verify and adjust detector response in industrial safety applications

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first