Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
GASCO Disposable Calibration Gas - Calibration Gases for Portable Gas Detectors
GASCOCalibration Gases for Portable Gas Detectors

GASCO Disposable Calibration Gas

The GASCO Calibration Gas: Nitrogen (MPN X02NI99CP1700P0) is a disposable calibration gas with +/-5% accuracy, featuring a CGA 600 connection and a gas mixture of Refrigerant R-22 700 ppm in a nitrogen background…

SKU 3G-OTH-550464

Brand
GASCO
Item
Disposable Calibration Gas
Part Number
X02NI99CP1700P0
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
X02NI99CP1700P0
Type
Disposable, +/-5% Accuracy, CHClF2, Calibration Gas, CGA 600
CGA Number
CGA 600
Gas Mixture
Refrigerant R-22 700 ppm
Reusability
Disposable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen (MPN X02NI99CP1700P0) is a disposable calibration gas with +/-5% accuracy, featuring a CGA 600 connection and a gas mixture of Refrigerant R-22 700 ppm in a nitrogen background. Designed for use with all OEM gas detectors, this product supports accurate sensor calibration across industrial safety applications.

Frequently Asked Questions

What is GASCO calibration gas with R-22 used for?

This GASCO disposable calibration gas is used to calibrate all OEM gas detectors that sense refrigerant R-22. The 700 ppm mixture in nitrogen ensures accurate sensor response for industrial safety compliance in HVAC and refrigeration applications.

What are the specifications of GASCO calibration gas X02NI99CP1700P0?

This GASCO calibration gas has a gas mixture of Refrigerant R-22 at 700 ppm in a nitrogen background, with +/-5% accuracy. It uses a CGA 600 connection, is disposable, and is designed for use with all OEM gas detectors.

Where to buy GASCO calibration gas in worldwide?

3G Electric supplies and delivers GASCO calibration gas worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to ensure your order arrives at your facility, wherever it is located.

How to use GASCO disposable calibration gas for R-22 detectors?

Attach the CGA 600 connection to your gas detector's regulator, open the valve, and expose the sensor to the 700 ppm R-22 mixture. Follow the detector manufacturer's calibration procedure. Dispose of the cylinder after use as it is non-refillable.

Not sure this is the right part? Photo-identify it→

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from GASCO

View all GASCO parts →
Disposable calibration gas cylinder containing 1,900 ppm methane in a nitrogen background. Provides +/-5% accuracy for verifying and calibrating portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas cylinder containing 1,900 ppm methane in a nitrogen background. Provides +/-5% accuracy for verifying and calibrating portable gas detectors in industrial safety applications. Compatible with all OEM gas detectors
Disposable calibration gas mixture containing 8.5 ppm nitrogen dioxide (NO2) in a nitrogen background, with +/-5% accuracy. Used to verify sensor accuracy and alarm set points of portable gas detectors that measure NO2 in industrial safety applications. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas mixture containing 8.5 ppm nitrogen dioxide (NO2) in a nitrogen background, with +/-5% accuracy. Used to verify sensor accuracy and alarm set points of portable gas detectors that measure NO2 in industrial safety applications. Compatible with all OEM gas detectors
This calibration gas contains 500 ppm of refrigerant R-134A in a background of air, with +/-2% accuracy. Supplied in a 105 L cylinder, it is used to verify and calibrate portable gas detectors for refrigerant leak detection in industrial environments
GASCO
This calibration gas contains 500 ppm of refrigerant R-134A in a background of air, with +/-2% accuracy. Supplied in a 105 L cylinder, it is used to verify and calibrate portable gas detectors for refrigerant leak detection in industrial environments
Disposable calibration gas mixture containing 213.54 ppm ethanol in nitrogen, with ±5% accuracy. Used to verify and calibrate portable gas detectors in industrial safety applications such as confined space entry and leak detection. Compatible with all OEM gas detectors
GASCO
Disposable calibration gas mixture containing 213.54 ppm ethanol in nitrogen, with ±5% accuracy. Used to verify and calibrate portable gas detectors in industrial safety applications such as confined space entry and leak detection. Compatible with all OEM gas detectors
Calibration gas mixture containing 500 ppm Refrigerant R-123A in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with all OEM gas detectors. Used to verify and adjust detector response in HVAC and industrial refrigeration applications
GASCO
Calibration gas mixture containing 500 ppm Refrigerant R-123A in nitrogen, with +/-2% accuracy. Supplied in a 105 L cylinder for use with all OEM gas detectors. Used to verify and adjust detector response in HVAC and industrial refrigeration applications
Calibration gas mixture containing 150 ppm Refrigerant R-123A in nitrogen background, supplied in a 105 L cylinder. Accuracy ±5%. Used for calibration of portable gas detectors in HVAC and industrial safety applications
GASCO
Calibration gas mixture containing 150 ppm Refrigerant R-123A in nitrogen background, supplied in a 105 L cylinder. Accuracy ±5%. Used for calibration of portable gas detectors in HVAC and industrial safety applications
Disposable calibration gas cylinder containing 25 ppm hydrogen sulfide in a nitrogen background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 25 ppm hydrogen sulfide in a nitrogen background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify and adjust sensor response in industrial safety applications
GASCO calibration gas mixture of Pentane (50% LEL) 0.7% in air background, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify and adjust sensor response for combustible gas monitoring in industrial safety applications
GASCO
GASCO calibration gas mixture of Pentane (50% LEL) 0.7% in air background, with +/-2% accuracy. Supplied in a 105 L cylinder for use with portable gas detectors. Used to verify and adjust sensor response for combustible gas monitoring in industrial safety applications

Customer reviews

No reviews yet — be the first

Questions & answers