GASCO Calibration Gas: Nitrogen

The GASCO Calibration Gas: Nitrogen is a refillable calibration gas for portable gas detectors, featuring a mixture of Hydrogen Sulfide 25 ppm with +/-5% accuracy. Designed for use with all OEM gas detectors, it uses…

SKU 3G-OTH-549456

Brand
GASCO
Item
Calibration Gas: Nitrogen
Part Number
X05NI85CA580003
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

GASCO
Manufacturer Part Number
X05NI85CA580003
Type
Refillable, +/-5% Accuracy, C5H12/CO/H2S/O2, Calibration Gas
Gas Mixture
Hydrogen Sulfide 25 ppm
Reusability
Refillable
For Use With
All OEM Gas Detectors
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

GASCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASCO Calibration Gas: Nitrogen is a refillable calibration gas for portable gas detectors, featuring a mixture of Hydrogen Sulfide 25 ppm with +/-5% accuracy. Designed for use with all OEM gas detectors, it uses a nitrogen background gas (MPN X05NI85CA580003).

Frequently Asked Questions

What is GASCO Calibration Gas: Nitrogen used for?

GASCO Calibration Gas: Nitrogen is used to calibrate portable gas detectors that sense hydrogen sulfide, carbon monoxide, pentane, and oxygen. It ensures detector accuracy for worker safety in industrial environments such as refineries, chemical plants, and confined spaces.

What are the specifications of GASCO Calibration Gas: Nitrogen?

This refillable calibration gas from GASCO contains a mixture of Hydrogen Sulfide 25 ppm with +/-5% accuracy. It uses a nitrogen background gas and is compatible with all OEM gas detectors. The manufacturer part number is X05NI85CA580003.

Where to buy GASCO Calibration Gas: Nitrogen in worldwide?

3G Electric supplies GASCO Calibration Gas: Nitrogen worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us to order the refillable calibration gas for your portable gas detectors.

How to maintain GASCO Calibration Gas: Nitrogen?

Store the refillable cylinder in a cool, dry area away from heat sources. Check the regulator and valve for leaks before each use. Follow the gas detector manufacturer's calibration schedule and replace the cylinder when the gas mixture is depleted to maintain +/-5% accuracy.

Not sure this is the right part? Photo-identify it→

GASCO Products

3G Electric supplies GASCO calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from GASCO

View all GASCO parts →
Calibration gas cylinder containing a certified mixture of 0.5% methane (10% LEL) in air, with +/-2% accuracy. The 105 L cylinder provides a stable reference for verifying and adjusting the accuracy of portable gas detectors that sense methane. Suitable for field or bench calibration of gas detection instruments
GASCO
Calibration gas cylinder containing a certified mixture of 0.5% methane (10% LEL) in air, with +/-2% accuracy. The 105 L cylinder provides a stable reference for verifying and adjusting the accuracy of portable gas detectors that sense methane. Suitable for field or bench calibration of gas detection instruments
Disposable calibration gas cylinder containing hydrogen at 4,000 ppm (10% LEL) in an air background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response for hydrogen. Cylinder capacity is 103 L
GASCO
Disposable calibration gas cylinder containing hydrogen at 4,000 ppm (10% LEL) in an air background, with ±5% accuracy. Designed for use with all OEM portable gas detectors to verify sensor response for hydrogen. Cylinder capacity is 103 L
Disposable calibration gas mixture containing 19.8% oxygen in nitrogen background gas, with ±5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify and adjust oxygen sensor response in industrial safety applications such as confined-space entry and area monitoring
GASCO
Disposable calibration gas mixture containing 19.8% oxygen in nitrogen background gas, with ±5% accuracy. Fitted with a CGA 600 connection for use with portable gas detectors. Used to verify and adjust oxygen sensor response in industrial safety applications such as confined-space entry and area monitoring
Disposable calibration gas mixture containing 500 ppm methyl mercaptan in nitrogen background gas. Accuracy ±5%. Used to verify the response of portable gas detectors that sense sulfur compounds in industrial safety applications such as oil and gas, wastewater treatment, and chemical processing
GASCO
Disposable calibration gas mixture containing 500 ppm methyl mercaptan in nitrogen background gas. Accuracy ±5%. Used to verify the response of portable gas detectors that sense sulfur compounds in industrial safety applications such as oil and gas, wastewater treatment, and chemical processing
Calibration gas cylinder containing Isobutylene (C4H8) at 1960 ppm (11% LEL) in an air background. ±2% accuracy. 105 L capacity. Used for calibration and bump testing of portable gas detectors from all OEMs
GASCO
Calibration gas cylinder containing Isobutylene (C4H8) at 1960 ppm (11% LEL) in an air background. ±2% accuracy. 105 L capacity. Used for calibration and bump testing of portable gas detectors from all OEMs
This calibration gas cylinder contains a mixture of 750 ppm hydrogen in air, with +/-2% accuracy. The 105 L cylinder is used to verify and adjust the response of portable gas detectors from various manufacturers. Suitable for field or bench calibration in industrial safety applications
GASCO
This calibration gas cylinder contains a mixture of 750 ppm hydrogen in air, with +/-2% accuracy. The 105 L cylinder is used to verify and adjust the response of portable gas detectors from various manufacturers. Suitable for field or bench calibration in industrial safety applications
Calibration gas cylinder containing Methane (17% LEL) at 0.85% concentration in air background. Accuracy ±2%. Cylinder capacity 105 L. Used for field or bench calibration of portable gas detectors to verify combustible gas readings
GASCO
Calibration gas cylinder containing Methane (17% LEL) at 0.85% concentration in air background. Accuracy ±2%. Cylinder capacity 105 L. Used for field or bench calibration of portable gas detectors to verify combustible gas readings
Disposable calibration gas cylinder containing 18.9% oxygen with nitrogen balance, ±5% accuracy. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications
GASCO
Disposable calibration gas cylinder containing 18.9% oxygen with nitrogen balance, ±5% accuracy. Used to verify and adjust the accuracy of portable gas detectors in industrial safety applications