Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASTEC 18L Ozone Gas Detection Tube, 0.025 to 6 ppm, 10-Pack - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC 18L Ozone Gas Detection Tube, 0.025 to 6 ppm, 10-Pack

The GASTEC Detector Tube (MPN 18L) is an ozone (O3) gas detection tube designed for use with GASTEC GV-100 and GV-110 pumps. It detects ozone across a measurement range of 0.025 to 6 ppm, supplied in a 10-pack. 3G…

SKU 3G-OTH-553224

Brand
GASTEC
Item
18L Ozone Gas Detection Tube, 0.025 to 6 ppm, 10-Pack
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

GASTEC
Manufacturer Part Number
18L
Type
O3, Gas Detection Tube, Ozone ( O3 ), With Pump, Ozone, 10 PK
Gas Detected
Ozone
Measurement Range
0.025 to 6 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 18L) is an ozone (O3) gas detection tube designed for use with GASTEC GV-100 and GV-110 pumps. It detects ozone across a measurement range of 0.025 to 6 ppm, supplied in a 10-pack. 3G Electric interprets your demand for this OEM-specific consumable, sourcing it alongside thousands of industrial parts across 14 departments — with specialist depth in combustion, pumps, and controls as an authorised distributor.

Frequently Asked Questions

What is the GASTEC 18L detector tube used for?

The GASTEC 18L detector tube is used to measure ozone (O3) concentrations in air, typically for industrial hygiene, workplace safety, and environmental monitoring. It works with GASTEC GV-100 and GV-110 pumps to detect ozone from 0.025 to 6 ppm.

What are the specifications of the GASTEC 18L ozone tube?

The GASTEC 18L tube detects ozone (O3) over a measurement range of 0.025 to 6 ppm. It is a gas detection tube designed for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. The manufacturer part number is 18L.

Where to buy GASTEC 18L detector tubes worldwide?

3G Electric supplies GASTEC 18L ozone detector tubes worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source this OEM consumable alongside thousands of parts across 14 departments.

How to use the GASTEC 18L tube with a GV-100 pump?

Break both tips of the GASTEC 18L tube, insert it into the GV-100 or GV-110 pump with the arrow pointing toward the pump, then pull the handle fully to draw a sample. Read the concentration directly from the tube scale. Follow the pump manual for stroke count and timing.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC detector tube 159 is used for the measurement of tetrahydrofuran (C4H8O) concentrations in air. It operates with GASTEC GV-100 and GV-110 pumps and provides a measurement range of 25 to 800 ppm. Supplied in a pack of 10 tubes, it is suitable for industrial hygiene surveys and leak detection applications
GASTEC
GASTEC detector tube 159 is used for the measurement of tetrahydrofuran (C4H8O) concentrations in air. It operates with GASTEC GV-100 and GV-110 pumps and provides a measurement range of 25 to 800 ppm. Supplied in a pack of 10 tubes, it is suitable for industrial hygiene surveys and leak detection applications
GASTEC 81D is a gas detection tube for measuring acetic acid (C2H4O2) concentrations in air, with a range of 0.5 to 100 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, it provides direct-reading measurements for industrial safety monitoring in environments such as chemical plants and laboratories. Supplied in a 10-pack
GASTEC
GASTEC 81D is a gas detection tube for measuring acetic acid (C2H4O2) concentrations in air, with a range of 0.5 to 100 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, it provides direct-reading measurements for industrial safety monitoring in environments such as chemical plants and laboratories. Supplied in a 10-pack
GASTEC 21LA gas detection tubes are used to measure carbonyl sulfide (COS) concentrations in industrial environments. Each pack contains 5 calibrated tubes with a measurement range of 2 to 125 ppm, designed for use with GASTEC GV-100 and GV-110 pumps
GASTEC
GASTEC 21LA gas detection tubes are used to measure carbonyl sulfide (COS) concentrations in industrial environments. Each pack contains 5 calibrated tubes with a measurement range of 2 to 125 ppm, designed for use with GASTEC GV-100 and GV-110 pumps
Gas detection tube for carbon monoxide (CO) measurement, calibrated for use with GASTEC GV-100 and GV-110 pumps. Measures CO concentrations from 25 to 2,000 ppm. Supplied in a pack of 10 tubes. Suitable for industrial safety, confined space entry, and environmental monitoring applications
GASTEC
Gas detection tube for carbon monoxide (CO) measurement, calibrated for use with GASTEC GV-100 and GV-110 pumps. Measures CO concentrations from 25 to 2,000 ppm. Supplied in a pack of 10 tubes. Suitable for industrial safety, confined space entry, and environmental monitoring applications
GASTEC detector tube 171 for acetylene (C2H2) gas. Designed for use with GASTEC GV-100 and GV-110 pumps. Measures acetylene concentrations from 0.05 to 4%. Supplied in a pack of 10 tubes
GASTEC
GASTEC detector tube 171 for acetylene (C2H2) gas. Designed for use with GASTEC GV-100 and GV-110 pumps. Measures acetylene concentrations from 0.05 to 4%. Supplied in a pack of 10 tubes
Calibrated gas detection tube for measuring sulphur dioxide (SO2) concentrations in air. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 0.1 to 22 ppm. Supplied in a pack of 10 tubes
GASTEC
Calibrated gas detection tube for measuring sulphur dioxide (SO2) concentrations in air. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 0.1 to 22 ppm. Supplied in a pack of 10 tubes
Gas detection tube for measuring trichloroethylene (C2HCl3) concentrations in air. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 3 to 300 ppm. Supplied in packs of 10. Used for on-site industrial hygiene monitoring and workplace safety assessments
GASTEC
Gas detection tube for measuring trichloroethylene (C2HCl3) concentrations in air. Designed for use with GASTEC GV-100 and GV-110 pumps. Measurement range: 3 to 300 ppm. Supplied in packs of 10. Used for on-site industrial hygiene monitoring and workplace safety assessments
GASTEC 91LL is a gas detection tube for formaldehyde (CH2O) with a measurement range of 0.05 to 1 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, it provides spot-check measurements for industrial hygiene, indoor air quality, or environmental monitoring. Supplied in a 10-pack
GASTEC
GASTEC 91LL is a gas detection tube for formaldehyde (CH2O) with a measurement range of 0.05 to 1 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, it provides spot-check measurements for industrial hygiene, indoor air quality, or environmental monitoring. Supplied in a 10-pack