Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 )

The GASTEC Detector Tube (MPN 3LA) is an ammonia (NH3) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects ammonia across a measurement range of 2.5 to 200 ppm.

SKU 3G-OTH-553099

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

GASTEC
Manufacturer Part Number
3LA
Type
NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK
Gas Detected
Ammonia
Measurement Range
2.5 to 200 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 3LA) is an ammonia (NH3) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects ammonia across a measurement range of 2.5 to 200 ppm.

Frequently Asked Questions

What is the GASTEC 3LA detector tube used for?

The GASTEC 3LA detector tube is used to measure ammonia (NH3) concentrations in air, typically for industrial hygiene, leak detection, or environmental monitoring. It works with GASTEC GV-100 and GV-110 pumps to provide a reading from 2.5 to 200 ppm.

What are the specifications of the GASTEC 3LA ammonia tube?

The GASTEC 3LA tube detects ammonia (NH3) over a measurement range of 2.5 to 200 ppm. It is designed for use with GASTEC GV-100 and GV-110 pumps and is supplied in a 10-pack. The manufacturer part number is 3LA.

Where to buy GASTEC 3LA detector tubes worldwide?

3G Electric supplies GASTEC 3LA ammonia detector tubes worldwide. As a global industrial sourcing partner, we handle logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this 10-pack of tubes for GV-100 pumps.

How to use the GASTEC 3LA ammonia detection tube?

To use the GASTEC 3LA tube, break both tips off using the tip breaker on the GV-100 or GV-110 pump. Insert the tube into the pump inlet with the arrow pointing toward the pump. Pull the handle to draw a full stroke of air, then read the stain length against the scale printed on the tube.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1M)
GASTEC
GASTEC Detector Tube: CO, Gas Detection Tube, Carbon Monoxide ( CO ), With Pump, Calibrated, 10 PK (MPN 1M)
GASTEC Detector Tube: Cl2, Gas Detection Tube, Chlorine ( Cl2 ), 104°F Max Op Temp [NEW], 10 PK (MPN 8D)
GASTEC
GASTEC Detector Tube: Cl2, Gas Detection Tube, Chlorine ( Cl2 ), 104°F Max Op Temp [NEW], 10 PK (MPN 8D)
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4HM)
GASTEC
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4HM)
GASTEC Detector Tube: GASTEC GV-100, CH3Br, Gas Detection Tube, Methyl Bromide ( CH3Br ), 5 PK (MPN 136L)
GASTEC
GASTEC Detector Tube: GASTEC GV-100, CH3Br, Gas Detection Tube, Methyl Bromide ( CH3Br ), 5 PK (MPN 136L)
GASTEC Detector Tube: GASTEC GV-100, SO2, Gas Detection Tube, Sulphur Dioxide ( SO2 ), 10 PK (MPN 5LB)
GASTEC
GASTEC Detector Tube: GASTEC GV-100, SO2, Gas Detection Tube, Sulphur Dioxide ( SO2 ), 10 PK (MPN 5LB)
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 0.2 to 200 ppm, 10 PK (MPN 4D)
GASTEC
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 0.2 to 200 ppm, 10 PK (MPN 4D)
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), With Pump, 6,000 mL, 10 PK (MPN 91P)
GASTEC
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), With Pump, 6,000 mL, 10 PK (MPN 91P)
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4LK)
GASTEC
GASTEC Detector Tube: H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), With Pump, 10 PK (MPN 4LK)