Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASTEC Detector Tube: HF, Gas Detection Tube, Hydrogen Fluoride ( HF ), 1 to 100 ppm - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: HF, Gas Detection Tube, Hydrogen Fluoride ( HF ), 1 to 100 ppm

The GASTEC Detector Tube: HF (MPN 17D) is a gas detection tube for use in GASTEC GV-100 and GV-110 pumps, detecting hydrogen fluoride across a measurement range of 1 to 100 ppm. Supplied in a 10-pack, this tube…

SKU 3G-OTH-553153

Brand
GASTEC
Item
Detector Tube: HF, Gas Detection Tube, Hydrogen Fluoride
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
17D
Type
Gas Detection Tube, Hydrogen Fluoride ( HF ), 1 to 100 ppm, 10 PK
Gas Detected
Hydrogen Fluoride
Measurement Range
1 to 100 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube: HF (MPN 17D) is a gas detection tube for use in GASTEC GV-100 and GV-110 pumps, detecting hydrogen fluoride across a measurement range of 1 to 100 ppm. Supplied in a 10-pack, this tube enables precise on-site measurement of HF concentrations. 3G Electric sources this genuine GASTEC consumable across 14 industrial departments, with specialist expertise in combustion, pumps, and controls ensuring accurate product selection and support.

Frequently Asked Questions

What is the GASTEC 17D detector tube used for?

The GASTEC 17D detector tube is used for on-site measurement of hydrogen fluoride (HF) gas concentrations in industrial environments. It works with GASTEC GV-100 and GV-110 pumps to detect HF from 1 to 100 ppm, supporting safety monitoring in chemical processing, metal finishing, and semiconductor manufacturing.

What are the specifications of the GASTEC 17D tube?

The GASTEC 17D tube detects hydrogen fluoride (HF) with a measurement range of 1 to 100 ppm. It is supplied in a 10-pack and is designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 17D. 3G Electric sources this genuine GASTEC consumable for worldwide delivery.

Where to buy GASTEC 17D detector tubes worldwide?

3G Electric supplies genuine GASTEC 17D detector tubes worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver this HF detection consumable to your facility. Contact us for availability and lead time on orders.

How to use the GASTEC 17D tube with a GV-100 pump?

To use the GASTEC 17D tube, break both tips off the tube using the tip breaker on the GV-100 or GV-110 pump. Insert the tube into the pump inlet with the arrow pointing toward the pump. Pull the handle to draw a sample; follow the pump instructions for stroke count. Read the concentration directly from the tube scale.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, O3, Gas Detection Tube, Ozone ( O3 ), With Pump, Ozone, 10 PK (MPN 18L). Key specifications — Gas Detected: Ozone; Measurement Range: 0.025 to 6 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, O3, Gas Detection Tube, Ozone ( O3 ), With Pump, Ozone, 10 PK (MPN 18L). Key specifications — Gas Detected: Ozone; Measurement Range: 0.025 to 6 ppm.
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), 2.5 to 30 ppm, 10 PK (MPN 72P). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 2.5 to 30 ppm.
GASTEC
GASTEC Detector Tube: C2H6S, Gas Detection Tube, Ethyl Mercaptan ( C2H6S ), 2.5 to 30 ppm, 10 PK (MPN 72P). Key specifications — Gas Detected: Ethyl Mercaptan; Measurement Range: 2.5 to 30 ppm.
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Stoddard Solvent, With Pump, 10 PK (MPN 128). Key specifications — Gas Detected: Stoddard Solvent; Measurement Range: 50 to 8,000 mg/m3.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Gas Detection Tube, Stoddard Solvent, With Pump, 10 PK (MPN 128). Key specifications — Gas Detected: Stoddard Solvent; Measurement Range: 50 to 8,000 mg/m3.
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3HM). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.05 to 3.52% vol.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3HM). Key specifications — Gas Detected: Ammonia; Measurement Range: 0.05 to 3.52% vol.
GASTEC Detector Tube: GASTEC GV-100, C7H8, Gas Detection Tube, Toluene ( C7H8 ), With Pump, 10 PK (MPN 122L). Key specifications — Gas Detected: Toluene; Measurement Range: 1 to 100 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C7H8, Gas Detection Tube, Toluene ( C7H8 ), With Pump, 10 PK (MPN 122L). Key specifications — Gas Detected: Toluene; Measurement Range: 1 to 100 ppm.
GASTEC Detector Tube: GASTEC GV-100, CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), 10 PK (MPN 91L). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.1 to 40 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), 10 PK (MPN 91L). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.1 to 40 ppm.
GASTEC Detector Tube: CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), With Pump, 10 PK (MPN 71H). Key specifications — Gas Detected: Methyl Mercaptan; Measurement Range: 20 to 2,700 ppm.
GASTEC
GASTEC Detector Tube: CH4S, Gas Detection Tube, Methyl Mercaptan ( CH4S ), With Pump, 10 PK (MPN 71H). Key specifications — Gas Detected: Methyl Mercaptan; Measurement Range: 20 to 2,700 ppm.
GASTEC Detector Tube: CH3OH, Gas Detection Tube, Methanol ( CH3OH ), With Pump, 2 to 62 ppm, 10 PK (MPN 111LL). Key specifications — Gas Detected: Methanol; Measurement Range: 2 to 62 ppm.
GASTEC
GASTEC Detector Tube: CH3OH, Gas Detection Tube, Methanol ( CH3OH ), With Pump, 2 to 62 ppm, 10 PK (MPN 111LL). Key specifications — Gas Detected: Methanol; Measurement Range: 2 to 62 ppm.