Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASTEC Detector Tube: GASTEC GV-100, H2O, Gas Detection Tube, Water Vapor ( H2O ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, H2O, Gas Detection Tube, Water Vapor ( H2O )

The GASTEC Detector Tube (MPN 6) is a water vapor (H2O) gas detection tube designed for use with GASTEC GV-100 and GV-110 pumps. It measures water vapor concentrations from 0.5 to 32 mg/L, supplied in a 10-pack.

SKU 3G-OTH-553210

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, H2O, Gas Detection Tube, Water Vapor
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
6
Type
H2O, Gas Detection Tube, Water Vapor ( H2O ), With Pump, 10 PK
Gas Detected
Water Vapor
Measurement Range
0.5 to 32 mg/L
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 6) is a water vapor (H2O) gas detection tube designed for use with GASTEC GV-100 and GV-110 pumps. It measures water vapor concentrations from 0.5 to 32 mg/L, supplied in a 10-pack.

Frequently Asked Questions

What is the GASTEC Detector Tube 6 used for?

The GASTEC Detector Tube 6 is used to measure water vapor (H2O) concentrations in air or gas streams. It works with GASTEC GV-100 and GV-110 pumps to detect levels from 0.5 to 32 mg/L, supporting industrial hygiene, compressed air quality checks, and process monitoring.

What are the specifications of the GASTEC Detector Tube 6?

The GASTEC Detector Tube 6 detects water vapor (H2O) with a measurement range of 0.5 to 32 mg/L. It is supplied in a 10-pack and designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 6.

Where to buy GASTEC Detector Tube 6 worldwide?

3G Electric supplies the GASTEC Detector Tube 6 worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this water vapor detection tube.

How to use the GASTEC Detector Tube 6 with a pump?

Break both tips of the GASTEC Detector Tube 6, insert it into the GASTEC GV-100 or GV-110 pump with the arrow pointing toward the pump, then pull the handle fully to draw a sample. Read the concentration directly from the tube scale after the recommended number of pump strokes.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121SL). Key specifications — Gas Detected: Benzene; Measurement Range: 1 to 100 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C6H6, Gas Detection Tube, Benzene ( C6H6 ), With Pump, 5 PK (MPN 121SL). Key specifications — Gas Detected: Benzene; Measurement Range: 1 to 100 ppm.
GASTEC Detector Tube: GASTEC GV-100, CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 10 PK (MPN 2LC). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 100 to 4,000 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 10 PK (MPN 2LC). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 100 to 4,000 ppm.
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 10 PK (MPN 4HH). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.1 to 4%.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 10 PK (MPN 4HH). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.1 to 4%.
GASTEC Detector Tube: Gas Detection Tube, LPG, With Pump, 104°F Max Op Temp [NEW], LPG, 10 PK (MPN 100A). Key specifications — Gas Detected: LPG; Measurement Range: 0.02 to 0.8%.
GASTEC
GASTEC Detector Tube: Gas Detection Tube, LPG, With Pump, 104°F Max Op Temp [NEW], LPG, 10 PK (MPN 100A). Key specifications — Gas Detected: LPG; Measurement Range: 0.02 to 0.8%.
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), 95°F Max Op Temp [NEW], 10 PK (MPN 91PL). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.01 to 0.8 ppm.
GASTEC
GASTEC Detector Tube: CH2O, Gas Detection Tube, Formaldehyde ( CH2O ), 95°F Max Op Temp [NEW], 10 PK (MPN 91PL). Key specifications — Gas Detected: Formaldehyde; Measurement Range: 0.01 to 0.8 ppm.
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3LA). Key specifications — Gas Detected: Ammonia; Measurement Range: 2.5 to 200 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3LA). Key specifications — Gas Detected: Ammonia; Measurement Range: 2.5 to 200 ppm.
GASTEC Detector Tube: GASTEC GV-100, C3H6O, Gas Detection Tube, Acetone ( C3H6O ), With Pump, 10 PK (MPN 151L). Key specifications — Gas Detected: Acetone; Measurement Range: 50 to 12,000 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C3H6O, Gas Detection Tube, Acetone ( C3H6O ), With Pump, 10 PK (MPN 151L). Key specifications — Gas Detected: Acetone; Measurement Range: 50 to 12,000 ppm.
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92L). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 1 to 20 ppm.
GASTEC
GASTEC Detector Tube: C2H4O, Gas Detection Tube, Acetaldehyde ( C2H4O ), With Pump, 10 PK (MPN 92L). Key specifications — Gas Detected: Acetaldehyde; Measurement Range: 1 to 20 ppm.