Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S )

The GASTEC Detector Tube (MPN 4M) is a hydrogen sulphide (H2S) gas detection tube, supplied in a 10-pack for use with GASTEC GV-100 and GV-110 pumps. It measures H2S concentrations from 12.5 to 500 ppm, enabling…

SKU 3G-OTH-553166

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
4M
Type
H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 10 PK
Gas Detected
Hydrogen Sulphide
Measurement Range
12.5 to 500 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 4M) is a hydrogen sulphide (H2S) gas detection tube, supplied in a 10-pack for use with GASTEC GV-100 and GV-110 pumps. It measures H2S concentrations from 12.5 to 500 ppm, enabling precise field sampling across 14 industrial departments — with specialist depth in combustion, pumps and controls as an authorised distributor.

Frequently Asked Questions

What is the GASTEC Detector Tube 4M used for?

The GASTEC Detector Tube 4M is used for measuring hydrogen sulphide (H2S) gas concentrations in industrial environments. It works with GASTEC GV-100 and GV-110 pumps to detect H2S from 12.5 to 500 ppm, supporting safety in combustion, pumps, and controls applications across 14 industrial departments.

What are the specifications of the GASTEC Detector Tube 4M?

The GASTEC Detector Tube 4M detects hydrogen sulphide (H2S) with a measurement range of 12.5 to 500 ppm. It is supplied in a 10-pack and is designed for use with GASTEC GV-100 and GV-110 pumps. The manufacturer part number is 4M.

Where to buy GASTEC Detector Tube 4M worldwide?

3G Electric supplies the GASTEC Detector Tube 4M worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us to order this H2S gas detection tube for use with GV-100 and GV-110 pumps.

How to use the GASTEC Detector Tube 4M with a GV-100 pump?

To use the GASTEC Detector Tube 4M, break both tips of the tube, insert it into the GASTEC GV-100 or GV-110 pump, and pull the handle to draw a sample. Follow the pump’s stroke count instructions for the 12.5 to 500 ppm range. Always refer to the tube’s instruction sheet for precise steps.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8HH). Key specifications — Gas Detected: Chlorine; Measurement Range: 0.25 to 10%.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8HH). Key specifications — Gas Detected: Chlorine; Measurement Range: 0.25 to 10%.
GASTEC Detector Tube: GASTEC GV-100, C8H8, Gas Detection Tube, Styrene ( C8H8 ), With Pump, 10 PK (MPN 124L). Key specifications — Gas Detected: Styrene; Measurement Range: 2 to 100 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C8H8, Gas Detection Tube, Styrene ( C8H8 ), With Pump, 10 PK (MPN 124L). Key specifications — Gas Detected: Styrene; Measurement Range: 2 to 100 ppm.
GASTEC Detector Tube: GASTEC GV-100, CH3Br, Gas Detection Tube, Methyl Bromide ( CH3Br ), 5 PK (MPN 136LA). Key specifications — Gas Detected: Methyl Bromide; Measurement Range: 1 to 36 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, CH3Br, Gas Detection Tube, Methyl Bromide ( CH3Br ), 5 PK (MPN 136LA). Key specifications — Gas Detected: Methyl Bromide; Measurement Range: 1 to 36 ppm.
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8LL). Key specifications — Gas Detected: Chlorine; Measurement Range: 0.025 to 2 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, Cl2, Gas Detection Tube, Chlorine ( Cl2 ), With Pump, 10 PK (MPN 8LL). Key specifications — Gas Detected: Chlorine; Measurement Range: 0.025 to 2 ppm.
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), With Pump, Calibrated, 10 PK (MPN 5LA). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 0.5 to 60 ppm.
GASTEC
GASTEC Detector Tube: SO2, Gas Detection Tube, Sulfur Dioxide ( SO2 ), With Pump, Calibrated, 10 PK (MPN 5LA). Key specifications — Gas Detected: Sulfur Dioxide; Measurement Range: 0.5 to 60 ppm.
GASTEC Detector Tube: GASTEC GV-100, NO2, Gas Detection Tube, Nitrogen Dioxide ( NO2 ), 10 PK (MPN 9L). Key specifications — Gas Detected: Nitrogen Dioxide; Measurement Range: 0.5 to 125 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NO2, Gas Detection Tube, Nitrogen Dioxide ( NO2 ), 10 PK (MPN 9L). Key specifications — Gas Detected: Nitrogen Dioxide; Measurement Range: 0.5 to 125 ppm.
GASTEC Detector Tube: GASTEC GV-100, C3H7NO, Gas Detection Tube, Dimethylformamide ( C3H7NO ), 10 PK (MPN 183). Key specifications — Gas Detected: Dimethylformamide; Measurement Range: 0.8 to 90 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C3H7NO, Gas Detection Tube, Dimethylformamide ( C3H7NO ), 10 PK (MPN 183). Key specifications — Gas Detected: Dimethylformamide; Measurement Range: 0.8 to 90 ppm.
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), 104°F Max Op Temp [NEW], 10 PK (MPN 6AH). Key specifications — Gas Detected: Water Vapor; Measurement Range: 500 to 5,000 ppm.
GASTEC
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), 104°F Max Op Temp [NEW], 10 PK (MPN 6AH). Key specifications — Gas Detected: Water Vapor; Measurement Range: 500 to 5,000 ppm.