Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

GASTEC Detector Tube: GASTEC GV-100, C8H8, Gas Detection Tube, Styrene ( C8H8 ) - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Detector Tube: GASTEC GV-100, C8H8, Gas Detection Tube, Styrene ( C8H8 )

The GASTEC Detector Tube (MPN 124) is a styrene (C8H8) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects styrene within a measurement range of 10 to 1,500 ppm.

SKU 3G-OTH-553193

Brand
GASTEC
Item
Detector Tube: GASTEC GV-100, C8H8, Gas Detection Tube, Styrene
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

GASTEC
Manufacturer Part Number
124
Type
C8H8, Gas Detection Tube, Styrene ( C8H8 ), With Pump, 10 PK
Gas Detected
Styrene
Measurement Range
10 to 1,500 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The GASTEC Detector Tube (MPN 124) is a styrene (C8H8) gas detection tube for use with GASTEC GV-100 and GV-110 pumps, supplied in a 10-pack. It detects styrene within a measurement range of 10 to 1,500 ppm.

Frequently Asked Questions

What is the GASTEC Detector Tube 124 used for?

The GASTEC Detector Tube 124 is used to measure styrene (C8H8) concentrations in air, typically in industrial hygiene, chemical processing, or manufacturing environments. It works with GASTEC GV-100 and GV-110 pumps to provide on-the-spot gas detection.

What are the specifications of the GASTEC Detector Tube 124?

The GASTEC Detector Tube 124 detects styrene (C8H8) with a measurement range of 10 to 1,500 ppm. It is designed for use with GASTEC GV-100 and GV-110 pumps and is supplied in a 10-pack. The manufacturer part number is 124.

Where to buy GASTEC Detector Tube 124 worldwide?

3G Electric supplies the GASTEC Detector Tube 124 worldwide, handling full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source and deliver genuine GASTEC gas detection tubes for styrene monitoring.

How to use the GASTEC Detector Tube 124 with a pump?

To use the GASTEC Detector Tube 124, break both ends of the tube, insert it into a GASTEC GV-100 or GV-110 pump, and pull the handle to draw a sample. Follow the pump's stroke count and timing instructions for the styrene measurement range of 10 to 1,500 ppm.

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from GASTEC

View all GASTEC parts
GASTEC Detector Tube: GASTEC GV-100, NO2, Gas Detection Tube, Nitrogen Dioxide ( NO2 ), 10 PK (MPN 9L). Key specifications — Gas Detected: Nitrogen Dioxide; Measurement Range: 0.5 to 125 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NO2, Gas Detection Tube, Nitrogen Dioxide ( NO2 ), 10 PK (MPN 9L). Key specifications — Gas Detected: Nitrogen Dioxide; Measurement Range: 0.5 to 125 ppm.
GASTEC Detector Tube: GASTEC GV-100, C3H7NO, Gas Detection Tube, Dimethylformamide ( C3H7NO ), 10 PK (MPN 183). Key specifications — Gas Detected: Dimethylformamide; Measurement Range: 0.8 to 90 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C3H7NO, Gas Detection Tube, Dimethylformamide ( C3H7NO ), 10 PK (MPN 183). Key specifications — Gas Detected: Dimethylformamide; Measurement Range: 0.8 to 90 ppm.
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), 104°F Max Op Temp [NEW], 10 PK (MPN 6AH). Key specifications — Gas Detected: Water Vapor; Measurement Range: 500 to 5,000 ppm.
GASTEC
GASTEC Detector Tube: H2O, Gas Detection Tube, Water Vapor ( H2O ), 104°F Max Op Temp [NEW], 10 PK (MPN 6AH). Key specifications — Gas Detected: Water Vapor; Measurement Range: 500 to 5,000 ppm.
GASTEC Detector Tube: GASTEC GV-100, C8H10, Gas Detection Tube, Xylene ( C8H10 ), With Pump, 10 PK (MPN 123). Key specifications — Gas Detected: Xylene; Measurement Range: 5 to 625 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, C8H10, Gas Detection Tube, Xylene ( C8H10 ), With Pump, 10 PK (MPN 123). Key specifications — Gas Detected: Xylene; Measurement Range: 5 to 625 ppm.
GASTEC Detector Tube: NO, Gas Detection Tube, Nitrogen Oxide ( NO ), With Pump, 5 to 625 ppm, 10 PK (MPN 11S). Key specifications — Gas Detected: Nitrogen Oxide; Measurement Range: 5 to 625 ppm.
GASTEC
GASTEC Detector Tube: NO, Gas Detection Tube, Nitrogen Oxide ( NO ), With Pump, 5 to 625 ppm, 10 PK (MPN 11S). Key specifications — Gas Detected: Nitrogen Oxide; Measurement Range: 5 to 625 ppm.
GASTEC Detector Tube: GASTEC GV-100, H2, Gas Detection Tube, Hydrogen ( H2 ), With Pump, 10 PK (MPN 30). Key specifications — Gas Detected: Hydrogen; Measurement Range: 0.5 to 2%.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, H2, Gas Detection Tube, Hydrogen ( H2 ), With Pump, 10 PK (MPN 30). Key specifications — Gas Detected: Hydrogen; Measurement Range: 0.5 to 2%.
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 10 PK (MPN 4LL). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.25 to 120 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, H2S, Gas Detection Tube, Hydrogen Sulphide ( H2S ), 10 PK (MPN 4LL). Key specifications — Gas Detected: Hydrogen Sulphide; Measurement Range: 0.25 to 120 ppm.
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3M). Key specifications — Gas Detected: Ammonia; Measurement Range: 10 to 1,000 ppm.
GASTEC
GASTEC Detector Tube: GASTEC GV-100, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN 3M). Key specifications — Gas Detected: Ammonia; Measurement Range: 10 to 1,000 ppm.