Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
GASTEC Gas Detection Tube for Sulfur Dioxide (SO2), 10-Pack, 0.2 to 100 ppm - Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
GASTECGas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps

GASTEC Gas Detection Tube for Sulfur Dioxide (SO2), 10-Pack, 0.2 to 100 ppm

<p>The GASTEC Gas Detection Tube for Sulfur Dioxide (SO2) is a precise, reliable solution for measuring SO2 concentrations in industrial environments. This 10-pack of tubes (Part No. 5D) offers a measurement range of…

SKU 3G-OTH-553222

Brand
GASTEC
Item
Gas Detection Tube for Sulfur Dioxide
Part Number
5D
Category
Gas Detection Tubes For Use In GASTEC GV-100 and GV-110 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

GASTEC
Manufacturer Part Number
5D
Type
Gas Detection Tube, Sulfur Dioxide ( SO2 ), 10 PK
Gas Detected
Sulfur Dioxide
Op Temp [NEW]
32°F Min
Measurement Range
0.2 to 100 ppm

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

GASTEC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

<p>The GASTEC Gas Detection Tube for Sulfur Dioxide (SO2) is a precise, reliable solution for measuring SO2 concentrations in industrial environments. This 10-pack of tubes (Part No. 5D) offers a measurement range of 0.2 to 100 ppm, suitable for a variety of applications including workplace safety, environmental monitoring, and industrial hygiene. Designed for use with GASTEC GV-100 and GV-110 pumps, these tubes provide accurate readings with a minimum operating temperature of 32°F.</p><p>Ideal for safety officers, environmental consultants, and facility managers, this product ensures compliance with air quality standards. As a Singapore-based supplier, 3G Electric offers SGD quotes on request, handles GST for local buyers, and provides fast delivery across Singapore and Southeast Asia, with worldwide shipping available.</p>

Frequently Asked Questions

What is the measurement range of the GASTEC 5D tube?

The GASTEC 5D tube detects sulfur dioxide (SO2) in the range of 0.2 to 100 ppm.

Which GASTEC pumps are compatible with this tube?

This tube is designed for use with GASTEC GV-100 and GV-110 pumps.

Not sure this is the right part? Photo-identify it→

GASTEC Products

3G Electric supplies GASTEC gas detection tubes for use in gastec gv-100 and gv-110 pumps. We supply genuine products and their technical documentation.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

Compatible alternatives & equivalents

More from GASTEC

View all GASTEC parts →
GASTEC 91LL is a gas detection tube for formaldehyde (CH2O) with a measurement range of 0.05 to 1 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, it provides spot-check measurements for industrial hygiene, indoor air quality, or environmental monitoring. Supplied in a 10-pack
GASTEC
GASTEC 91LL is a gas detection tube for formaldehyde (CH2O) with a measurement range of 0.05 to 1 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, it provides spot-check measurements for industrial hygiene, indoor air quality, or environmental monitoring. Supplied in a 10-pack
GASTEC 21LA gas detection tubes are used to measure carbonyl sulfide (COS) concentrations in industrial environments. Each pack contains 5 calibrated tubes with a measurement range of 2 to 125 ppm, designed for use with GASTEC GV-100 and GV-110 pumps
GASTEC
GASTEC 21LA gas detection tubes are used to measure carbonyl sulfide (COS) concentrations in industrial environments. Each pack contains 5 calibrated tubes with a measurement range of 2 to 125 ppm, designed for use with GASTEC GV-100 and GV-110 pumps
GASTEC gas detection tube for chlorine (Cl2), designed for use with GV-100 and GV-110 pumps. Measures chlorine concentrations from 0.08 to 100 ppm. Maximum operating temperature 104°F. Pack of 10 tubes
GASTEC
GASTEC gas detection tube for chlorine (Cl2), designed for use with GV-100 and GV-110 pumps. Measures chlorine concentrations from 0.08 to 100 ppm. Maximum operating temperature 104°F. Pack of 10 tubes
GASTEC 101L is a CNHM-type gas detection tube for measuring gasoline vapor concentrations. It is designed for use with GASTEC GV-100 and GV-110 pumps, providing a measurement range of 30 to 2,000 ppm. Supplied as a 10-pack, it enables on-site air sampling in industrial environments where gasoline vapors may be present
GASTEC
GASTEC 101L is a CNHM-type gas detection tube for measuring gasoline vapor concentrations. It is designed for use with GASTEC GV-100 and GV-110 pumps, providing a measurement range of 30 to 2,000 ppm. Supplied as a 10-pack, it enables on-site air sampling in industrial environments where gasoline vapors may be present
GASTEC detector tube 103 is a hydrocarbon (C3H4) gas detection tube with a measurement range of 0.05 to 2.4%. Designed for use with GASTEC GV-100 and GV-110 pumps, it is supplied in a pack of 9. Used for monitoring hydrocarbon gas concentrations in industrial environments such as combustion, chemical, and manufacturing facilities
GASTEC
GASTEC detector tube 103 is a hydrocarbon (C3H4) gas detection tube with a measurement range of 0.05 to 2.4%. Designed for use with GASTEC GV-100 and GV-110 pumps, it is supplied in a pack of 9. Used for monitoring hydrocarbon gas concentrations in industrial environments such as combustion, chemical, and manufacturing facilities
GASTEC 133D is a gas detection tube for measuring tetrachloroethylene (C2Cl4) concentrations in air, with a measurement range of 3 to 150 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, this 10-pack is suitable for industrial hygiene monitoring and chemical exposure assessment in environments where tetrachloroethylene may be present
GASTEC
GASTEC 133D is a gas detection tube for measuring tetrachloroethylene (C2Cl4) concentrations in air, with a measurement range of 3 to 150 ppm. Designed for use with GASTEC GV-100 and GV-110 pumps, this 10-pack is suitable for industrial hygiene monitoring and chemical exposure assessment in environments where tetrachloroethylene may be present
GASTEC 4D is a gas detection tube for measuring hydrogen sulphide (H2S) concentrations in air. It has a measurement range of 0.2 to 200 ppm and is supplied in packs of 10. Designed for use with GASTEC GV-100 and GV-110 pumps, it is suitable for on-site detection in industrial environments such as refineries, wastewater treatment plants, and chemical processing facilities
GASTEC
GASTEC 4D is a gas detection tube for measuring hydrogen sulphide (H2S) concentrations in air. It has a measurement range of 0.2 to 200 ppm and is supplied in packs of 10. Designed for use with GASTEC GV-100 and GV-110 pumps, it is suitable for on-site detection in industrial environments such as refineries, wastewater treatment plants, and chemical processing facilities
GASTEC 9L gas detection tube for nitrogen dioxide (NO2) with a measurement range of 0.5 to 125 ppm. Pack of 10 tubes for use with GASTEC GV-100 and GV-110 pumps. Suitable for field sampling in industrial environments where NO2 monitoring is required
GASTEC
GASTEC 9L gas detection tube for nitrogen dioxide (NO2) with a measurement range of 0.5 to 125 ppm. Pack of 10 tubes for use with GASTEC GV-100 and GV-110 pumps. Suitable for field sampling in industrial environments where NO2 monitoring is required

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first