Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

HACH LPV444.99.00320 Turbidity Meter, 0 to 10000 NTU - Turbidity Meters
HACHTurbidity Meters

HACH LPV444.99.00320 Turbidity Meter, 0 to 10000 NTU

The HACH Turbidity Meter (SKU LPV444.99.00320, manufacturer part number LPV444.99.00320) measures turbidity across a range of 0 to 10000 NTU. It offers a turbidity accuracy of FNU: +/-2% of reading plus 0.01 FNU from…

SKU 3G-OTH-371211

Also listed as: LPV4449900320 · LPV444 99 00320 · LPV444-99-00320

Brand
HACH
Item
LPV444.99.00320 Turbidity Meter, 0 to 10000 NTU
Category
Turbidity Meters
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

HACH
Manufacturer Part Number
LPV444.99.00320
Type
LPV444.99.00320
Range
0 to 10000 NTU
Includes
Silicone Oil
Product Type
Turbidity Meter
Turbidity Accuracy
FNU: +/-2% of Reading Plus 0.01 FNU from 0 - 1000 FNU
NTU Turbidity Resolution
0

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HACH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HACH Turbidity Meter (SKU LPV444.99.00320, manufacturer part number LPV444.99.00320) measures turbidity across a range of 0 to 10000 NTU. It offers a turbidity accuracy of FNU: +/-2% of reading plus 0.01 FNU from 0 to 1000 FNU and includes silicone oil. This instrument provides a 0 NTU turbidity resolution.

Frequently Asked Questions

What is the HACH Turbidity Meter LPV444.99.00320 used for?

The HACH Turbidity Meter measures water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control. It detects suspended particles across a 0 to 10000 NTU range, with accuracy of +/-2% of reading plus 0.01 FNU from 0 to 1000 FNU.

What are the specifications of the HACH Turbidity Meter LPV444.99.00320?

This HACH Turbidity Meter has a range of 0 to 10000 NTU, turbidity accuracy of FNU: +/-2% of reading plus 0.01 FNU from 0 to 1000 FNU, and 0 NTU turbidity resolution. It includes silicone oil and is model LPV444.99.00320.

Where to buy the HACH Turbidity Meter LPV444.99.00320 worldwide?

3G Electric supplies the HACH Turbidity Meter LPV444.99.00320 to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this instrument.

How to maintain the HACH Turbidity Meter LPV444.99.00320?

Regularly clean the sample cell and apply the included silicone oil to maintain optical clarity. Calibrate using certified standards per the manufacturer's instructions. Store in a clean, dry environment when not in use to ensure consistent accuracy across the 0 to 10000 NTU range.

Used in

Common applications for HACH
Municipal water treatment — HACH PHC20101 IntelliCAL pH electrode for pH monitoring in distribution systems
Industrial wastewater — HACH Chloride Test Kit (2438600) for chlorine residual analysis in effluent
Laboratory analysis — HACH Buffer Standard Solution S11M005 for calibrating pH meters in quality control labs
Environmental field testing — HACH Chemical Test Strips (2793828) for rapid water quality screening
Process water monitoring — HACH Probe LZW5056.97.0002 for ORP measurement in cooling towers
Wastewater treatment — HACH Water Quality Test Kit (2182000) for nitrite monitoring in biological treatment processes

HACH Products

3G Electric supplies HACH turbidity meters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Variable area inline flowmeter with scale display for petroleum fluids. Viton seals and O-rings, +/-2% accuracy, universal mounting orientation. Measures in liters, NPTF connections. Suitable for hydraulic, lubrication, and oil transfer systems
HEDLAND
Variable area inline flowmeter with scale display for petroleum fluids. Viton seals and O-rings, +/-2% accuracy, universal mounting orientation. Measures in liters, NPTF connections. Suitable for hydraulic, lubrication, and oil transfer systems
Scale-type, variable area, inline flowmeter with NPTF connections for measuring flow rate of petroleum fluids. Features +/-2% accuracy, Viton seals and O-rings, and universal mounting orientation. Measures in liters. Suitable for industrial hydraulic systems, lubrication circuits, and oil transfer applications
HEDLAND
Scale-type, variable area, inline flowmeter with NPTF connections for measuring flow rate of petroleum fluids. Features +/-2% accuracy, Viton seals and O-rings, and universal mounting orientation. Measures in liters. Suitable for industrial hydraulic systems, lubrication circuits, and oil transfer applications
This inline variable area flowmeter from HEDLAND measures flow rates of petroleum fluids in liters. It features a scale display, Viton seals and O-rings, and universal mounting orientation. Accuracy is +/-2%. Connections are NPTF. Suitable for industrial hydraulic and lubrication systems
HEDLAND
This inline variable area flowmeter from HEDLAND measures flow rates of petroleum fluids in liters. It features a scale display, Viton seals and O-rings, and universal mounting orientation. Accuracy is +/-2%. Connections are NPTF. Suitable for industrial hydraulic and lubrication systems
This inline variable-area flowmeter measures flow rate of petroleum fluids such as hydraulic oils and lubricants. It features a scale display with +/-2% accuracy, Viton seals and O-rings, and universal mounting orientation. The unit measures flow in gallons and does not include a pressure gauge or flow rate adjustment knob
HEDLAND
This inline variable-area flowmeter measures flow rate of petroleum fluids such as hydraulic oils and lubricants. It features a scale display with +/-2% accuracy, Viton seals and O-rings, and universal mounting orientation. The unit measures flow in gallons and does not include a pressure gauge or flow rate adjustment knob
Scale-type, variable area, inline flowmeter for petroleum fluids. Features +/-2% accuracy, Viton seals and O-rings, and universal mounting orientation. Measures flow in gallons with NPTF connections. Suitable for industrial fluid power systems and lubrication circuits
HEDLAND
Scale-type, variable area, inline flowmeter for petroleum fluids. Features +/-2% accuracy, Viton seals and O-rings, and universal mounting orientation. Measures flow in gallons with NPTF connections. Suitable for industrial fluid power systems and lubrication circuits
Variable area inline flowmeter with scale display for measuring flow of petroleum fluids. Features NPTF connections, Viton seals and O-rings, and universal mounting orientation. Accuracy ±7%. Suitable for hydraulic systems, lubrication circuits, and fuel transfer applications
HEDLAND
Variable area inline flowmeter with scale display for measuring flow of petroleum fluids. Features NPTF connections, Viton seals and O-rings, and universal mounting orientation. Accuracy ±7%. Suitable for hydraulic systems, lubrication circuits, and fuel transfer applications

More from HACH

View all HACH parts
The HACH 2100Q01 turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ±2% of reading plus stray light. It includes an oiling cloth for maintenance. Suitable for monitoring water quality in treatment processes and environmental testing
HACH
The HACH 2100Q01 turbidity meter measures water clarity over a range of 0 to 1000 NTU with an accuracy of ±2% of reading plus stray light. It includes an oiling cloth for maintenance. Suitable for monitoring water quality in treatment processes and environmental testing
Turbidity meter with a measurement range of 0 to 10000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, ±5% from 1000 to 4000 NTU, and ±10% from 4000 to 10000 NTU (Ratio on). Includes oiling cloth. Complies with CE, KC, RCM standards and EPA Method 180.1. Suitable for water clarity testing in laboratory and field applications
HACH
Turbidity meter with a measurement range of 0 to 10000 NTU and 0 NTU resolution. Accuracy is ±2% of reading plus 0.01 NTU from 0 to 1000 NTU, ±5% from 1000 to 4000 NTU, and ±10% from 4000 to 10000 NTU (Ratio on). Includes oiling cloth. Complies with CE, KC, RCM standards and EPA Method 180.1. Suitable for water clarity testing in laboratory and field applications
Turbidity meter for measuring water clarity by detecting suspended particles. Range 0 to 700 NTU/FNU/TE/F/FTU with accuracy ±2% plus 0.01 NTU from 0 to 40 NTU. Includes dust cover. Used in water quality analysis for drinking water, wastewater, and industrial process monitoring
HACH
Turbidity meter for measuring water clarity by detecting suspended particles. Range 0 to 700 NTU/FNU/TE/F/FTU with accuracy ±2% plus 0.01 NTU from 0 to 40 NTU. Includes dust cover. Used in water quality analysis for drinking water, wastewater, and industrial process monitoring
Turbidity meter for measuring suspended particles in liquids, with a range of 0 to 175 EBC and accuracy of +/-2% plus 0.01 NTU from 0 to 40 NTU. Includes power supply. Commonly used in water treatment and industrial process monitoring
HACH
Turbidity meter for measuring suspended particles in liquids, with a range of 0 to 175 EBC and accuracy of +/-2% plus 0.01 NTU from 0 to 40 NTU. Includes power supply. Commonly used in water treatment and industrial process monitoring
Turbidity meter with a measurement range of 0 to 10000 NTU. Accuracy is ±2% of reading plus 0.01 FNU/NTU from 0 to 1000 FNU/NTU. Includes power cord. Used for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control
HACH
Turbidity meter with a measurement range of 0 to 10000 NTU. Accuracy is ±2% of reading plus 0.01 FNU/NTU from 0 to 1000 FNU/NTU. Includes power cord. Used for measuring water clarity in applications such as drinking water treatment, wastewater monitoring, and industrial process control
Turbidity meter with a measurement range of 0 to 175 EBC and accuracy of ±10% of reading from 40 to 1000 NTU based on Formazin Primary Standard at 25 °C. Includes Stablcal Calibration Kit. Used for measuring water clarity in industrial and municipal applications such as wastewater treatment and process monitoring
HACH
Turbidity meter with a measurement range of 0 to 175 EBC and accuracy of ±10% of reading from 40 to 1000 NTU based on Formazin Primary Standard at 25 °C. Includes Stablcal Calibration Kit. Used for measuring water clarity in industrial and municipal applications such as wastewater treatment and process monitoring
Turbidity meter with Flow-Thru Head, Tygon Tubing, and USB Cable. CE-marked Type AB/Vial Replacement Tool for measuring water clarity in industrial and environmental applications
HACH
Turbidity meter with Flow-Thru Head, Tygon Tubing, and USB Cable. CE-marked Type AB/Vial Replacement Tool for measuring water clarity in industrial and environmental applications
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing
HACH
Turbidity meter for measuring water clarity in the range of 0 to 1000 NTU. Provides accuracy of +/-2% of reading plus stray light. Includes power module. Suitable for field or laboratory use in water quality testing