Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

HACH Sodium Ion Selective Electrode LZW9650.97.0002 - Ion Selective Electrodes
HACHIon Selective Electrodes

HACH Sodium Ion Selective Electrode LZW9650.97.0002

The HACH Electrode LZW9650.97.0002 is an Ion Selective Electrode designed for sodium measurement. It features a glass body, a BNC connection type, and a measurement range of 0.05 to 23000. The electrode includes a 1…

SKU 3G-OTH-375780

Also listed as: LZW9650970002 · LZW9650 97 0002 · LZW9650-97-0002

Brand
HACH
Item
Sodium Ion Selective Electrode LZW9650.97.0002
Category
Ion Selective Electrodes
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

HACH
Manufacturer Part Number
LZW9650.97.0002
Type
Sodium, 0.05 to 23000, BNC
Material
Glass
Range
0.05 to 23000
Cable Lg
1 m
Overall Dia
1/2 in
Product Type
Electrode
Connection Type
BNC
Test Parameters
Sodium

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HACH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HACH Electrode LZW9650.97.0002 is an Ion Selective Electrode designed for sodium measurement. It features a glass body, a BNC connection type, and a measurement range of 0.05 to 23000. The electrode includes a 1 m cable length and has a 1/2 in overall diameter.

Frequently Asked Questions

What is the HACH LZW9650.97.0002 electrode used for?

The HACH LZW9650.97.0002 is an ion selective electrode (ISE) used to measure sodium ion concentration in water and wastewater samples. It is commonly applied in environmental monitoring, laboratory analysis, and industrial process control where precise sodium levels from 0.05 to 23000 are required.

What are the specifications of the HACH LZW9650.97.0002 electrode?

The HACH LZW9650.97.0002 is a glass-body sodium electrode with a BNC connector, a 1 m cable length, and a 1/2 in overall diameter. Its measurement range is 0.05 to 23000. The manufacturer part number is LZW9650.97.0002, and it is classified as an ion selective electrode.

Where to buy the HACH LZW9650.97.0002 electrode worldwide?

3G Electric supplies the HACH LZW9650.97.0002 electrode worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us to source this sodium ISE for your laboratory or process application.

How to maintain the HACH LZW9650.97.0002 sodium electrode?

To maintain the HACH LZW9650.97.0002, rinse the glass body with deionized water after each use and store it in a sodium ISE storage solution. Avoid touching the glass membrane. Regularly calibrate with known sodium standards to ensure accurate readings. Replace the electrode if response becomes sluggish.

Used in

Common applications for HACH
Municipal water treatment — HACH PHC20101 IntelliCAL pH electrode for pH monitoring in distribution systems
Industrial wastewater — HACH Chloride Test Kit (2438600) for chlorine residual analysis in effluent
Laboratory analysis — HACH Buffer Standard Solution S11M005 for calibrating pH meters in quality control labs
Environmental field testing — HACH Chemical Test Strips (2793828) for rapid water quality screening
Process water monitoring — HACH Probe LZW5056.97.0002 for ORP measurement in cooling towers
Wastewater treatment — HACH Water Quality Test Kit (2182000) for nitrite monitoring in biological treatment processes

HACH Products

3G Electric supplies HACH ion selective electrodes. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Ion selective electrode for measuring nitrate concentration in aqueous solutions. Features a PVC body with a porous annular PTFE junction and BNC connector. Measurement range 0.1 to 14000 mg/L, cable length 1 m. Suitable for laboratory and field water analysis
HACH
Ion selective electrode for measuring nitrate concentration in aqueous solutions. Features a PVC body with a porous annular PTFE junction and BNC connector. Measurement range 0.1 to 14000 mg/L, cable length 1 m. Suitable for laboratory and field water analysis
Fluoride ion selective electrode with a measurement range of 0.01 to 19000 mg/L. Features an epoxy body, BNC connector, 1 m cable, and porous annular PTFE junction. Used for direct measurement of fluoride concentration in aqueous solutions
HACH
Fluoride ion selective electrode with a measurement range of 0.01 to 19000 mg/L. Features an epoxy body, BNC connector, 1 m cable, and porous annular PTFE junction. Used for direct measurement of fluoride concentration in aqueous solutions
This ammonium ion selective electrode has a measurement range of 0.018 to 9000 mg/L. It features a PVC body, porous annular PTFE junction, and BNC connector with a 1 m cable. Used for determining ammonium concentration in aqueous solutions
HACH
This ammonium ion selective electrode has a measurement range of 0.018 to 9000 mg/L. It features a PVC body, porous annular PTFE junction, and BNC connector with a 1 m cable. Used for determining ammonium concentration in aqueous solutions
Fluoride ion selective electrode with a measurement range of 0.02 mg/L to 20000 mg/L F-. Features a porous annular PTFE junction, epoxy body, and BNC connection with 1 m cable. Used for determining fluoride concentration in aqueous solutions
HACH
Fluoride ion selective electrode with a measurement range of 0.02 mg/L to 20000 mg/L F-. Features a porous annular PTFE junction, epoxy body, and BNC connection with 1 m cable. Used for determining fluoride concentration in aqueous solutions
Plastic-body sodium ion selective electrode with a double porous pin junction. Measures sodium ion concentration from 0.023 mg/L (1 x 10⁻⁶ M) to 23 g/L (1 M) Na⁺. Includes a 1 m cable. Used for sodium ion analysis in aqueous solutions
HACH
Plastic-body sodium ion selective electrode with a double porous pin junction. Measures sodium ion concentration from 0.023 mg/L (1 x 10⁻⁶ M) to 23 g/L (1 M) Na⁺. Includes a 1 m cable. Used for sodium ion analysis in aqueous solutions
Sodium ion selective electrode with a double porous pin junction and plastic body. Measures sodium ion concentration from 0.023 mg/L (1 x 10⁻⁶ M) to 23 g/L (1 M) Na⁺. Includes a 3 m cable. Used for direct measurement of sodium in aqueous solutions in laboratory and field applications
HACH
Sodium ion selective electrode with a double porous pin junction and plastic body. Measures sodium ion concentration from 0.023 mg/L (1 x 10⁻⁶ M) to 23 g/L (1 M) Na⁺. Includes a 3 m cable. Used for direct measurement of sodium in aqueous solutions in laboratory and field applications

More from HACH

View all HACH parts
This ion selective electrode measures chloride concentration in aqueous solutions. It features a double junction and epoxy body for durability. The electrode covers a range of 0.1 mg/L to 35.5 g/L and includes a 1 m cable. Typical applications include water quality testing and laboratory analysis
HACH
This ion selective electrode measures chloride concentration in aqueous solutions. It features a double junction and epoxy body for durability. The electrode covers a range of 0.1 mg/L to 35.5 g/L and includes a 1 m cable. Typical applications include water quality testing and laboratory analysis
Plastic-body sodium ion selective electrode with double porous pin junction. Measures sodium ion concentration from 0.023 mg/L (1 x 10⁻⁶ M) to 23 g/L (1 M) Na⁺. Includes 1 m cable. Used for direct measurement of sodium in aqueous solutions in laboratory and field applications
HACH
Plastic-body sodium ion selective electrode with double porous pin junction. Measures sodium ion concentration from 0.023 mg/L (1 x 10⁻⁶ M) to 23 g/L (1 M) Na⁺. Includes 1 m cable. Used for direct measurement of sodium in aqueous solutions in laboratory and field applications
Epoxy-body ion selective electrode for measurement of fluoride ion concentration in aqueous solutions. Range 0.02 mg/L to 20000 mg/L F- with BNC connector and 1 m cable. Used in water quality analysis and process monitoring
HACH
Epoxy-body ion selective electrode for measurement of fluoride ion concentration in aqueous solutions. Range 0.02 mg/L to 20000 mg/L F- with BNC connector and 1 m cable. Used in water quality analysis and process monitoring
Plastic-body, double-junction ammonium electrode for measuring NH4-N concentration from 0.018 mg/L (10⁻⁶ M) to 9 g/L (0.5 M). Includes 1 m cable. Used in water and wastewater analysis for environmental monitoring and process control
HACH
Plastic-body, double-junction ammonium electrode for measuring NH4-N concentration from 0.018 mg/L (10⁻⁶ M) to 9 g/L (0.5 M). Includes 1 m cable. Used in water and wastewater analysis for environmental monitoring and process control
Ion selective electrode for ammonia (NH3-N) measurement. Features a double annular junction and epoxy body. Measurement range from 0.01 mg/L (5 x 10-7 M) to 14 g/L (1 M) NH3-N. Includes 3 m cable. Used in water and wastewater analysis for environmental monitoring and process control
HACH
Ion selective electrode for ammonia (NH3-N) measurement. Features a double annular junction and epoxy body. Measurement range from 0.01 mg/L (5 x 10-7 M) to 14 g/L (1 M) NH3-N. Includes 3 m cable. Used in water and wastewater analysis for environmental monitoring and process control
Plastic-bodied nitrate ion selective electrode with double junction and 3 m cable. Measures nitrate as NO3-N from 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M). Used for direct determination of nitrate concentration in aqueous samples in laboratory and field applications
HACH
Plastic-bodied nitrate ion selective electrode with double junction and 3 m cable. Measures nitrate as NO3-N from 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M). Used for direct determination of nitrate concentration in aqueous samples in laboratory and field applications
Plastic-body ion selective electrode for fluoride measurement in aqueous solutions. Features an annular PTFE junction and a measurement range of 0.01 mg/L (5 x 10⁻⁷ M) to 19 g/L (1 M) F⁻. Includes a 1 m cable. Used in water quality testing and environmental monitoring
HACH
Plastic-body ion selective electrode for fluoride measurement in aqueous solutions. Features an annular PTFE junction and a measurement range of 0.01 mg/L (5 x 10⁻⁷ M) to 19 g/L (1 M) F⁻. Includes a 1 m cable. Used in water quality testing and environmental monitoring
Epoxy-bodied ion selective electrode for measuring chloride concentration in aqueous solutions. Range: 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-. Fitted with a 1 m cable and BNC connector for use with compatible meters
HACH
Epoxy-bodied ion selective electrode for measuring chloride concentration in aqueous solutions. Range: 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-. Fitted with a 1 m cable and BNC connector for use with compatible meters