Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

HACH Electrode: LZW9662C.97.002, Nitrate, 0.1 to 14000, 1 m Cable Lg, BNC - Ion Selective Electrodes
HACHIon Selective Electrodes

HACH Electrode: LZW9662C.97.002, Nitrate, 0.1 to 14000, 1 m Cable Lg, BNC

The HACH Electrode LZW9662C.97.002 is an Ion Selective Electrode designed for nitrate testing with a range of 0.1 to 14000. It features a PVC body, a Porous Annular PTFE junction, and a BNC connection type, with a 1…

SKU 3G-OTH-375784

Also listed as: LZW9662C97002 · LZW9662C 97 002 · LZW9662C-97-002

Brand
HACH
Item
Electrode: LZW9662C.97.002, Nitrate, 0.1 to 14000, 1 m Cable Lg, BNC
Category
Ion Selective Electrodes
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

HACH
Manufacturer Part Number
LZW9662C.97.002
Type
Nitrate, 0.1 to 14000, BNC, Porous Annular PTFE
Material
PVC
Range
0.1 to 14000
Cable Lg
1 m
Junction
Porous Annular PTFE
Product Type
Electrode
Connection Type
BNC
Test Parameters
Nitrate

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HACH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HACH Electrode LZW9662C.97.002 is an Ion Selective Electrode designed for nitrate testing with a range of 0.1 to 14000. It features a PVC body, a Porous Annular PTFE junction, and a BNC connection type, with a 1 m cable length.

Frequently Asked Questions

What is the HACH LZW9662C.97.002 electrode used for?

The HACH LZW9662C.97.002 is an ion selective electrode (ISE) used for measuring nitrate concentration in water samples. It is commonly applied in environmental monitoring, wastewater treatment, and laboratory analysis to detect nitrate levels from 0.1 to 14000.

What are the specifications of the HACH LZW9662C.97.002 nitrate electrode?

The HACH LZW9662C.97.002 is a nitrate ISE with a measurement range of 0.1 to 14000. It features a PVC body, a Porous Annular PTFE junction, a BNC connector, and a 1 m cable length. The manufacturer part number is LZW9662C.97.002.

Where to buy the HACH LZW9662C.97.002 electrode worldwide?

3G Electric supplies the HACH LZW9662C.97.002 nitrate electrode worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to maintain the HACH LZW9662C.97.002 nitrate electrode?

To maintain the HACH LZW9662C.97.002, rinse the electrode with deionized water after each use and store it in a recommended storage solution. Avoid touching the membrane. Regularly recalibrate using nitrate standards to ensure accurate readings. Replace if response becomes sluggish.

Used in

Common applications for HACH
Municipal water treatment — HACH PHC20101 IntelliCAL pH electrode for pH monitoring in distribution systems
Industrial wastewater — HACH Chloride Test Kit (2438600) for chlorine residual analysis in effluent
Laboratory analysis — HACH Buffer Standard Solution S11M005 for calibrating pH meters in quality control labs
Environmental field testing — HACH Chemical Test Strips (2793828) for rapid water quality screening
Process water monitoring — HACH Probe LZW5056.97.0002 for ORP measurement in cooling towers
Wastewater treatment — HACH Water Quality Test Kit (2182000) for nitrite monitoring in biological treatment processes

HACH Products

3G Electric supplies HACH ion selective electrodes. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
HACH Electrode: LZW9655C.97.002, Fluoride, 0.01 to 19000, 1 m Cable Lg, BNC, Porous Annular PTFE
HACH
HACH Electrode: LZW9655C.97.002, Fluoride, 0.01 to 19000, 1 m Cable Lg, BNC, Porous Annular PTFE
HACH Electrode: LZW9652.97.0002, Chloride, 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-, 1 m Cable Lg
HACH
HACH Electrode: LZW9652.97.0002, Chloride, 1 mg/L (3 x 10-6M) to 35500 mg/L (1 M) Cl-, 1 m Cable Lg
HACH Electrode: LZW9655.97.0002, Fluoride, 0.02 mg/L to 20000 mg/L F-, 1 m Cable Lg, BNC
HACH
HACH Electrode: LZW9655.97.0002, Fluoride, 0.02 mg/L to 20000 mg/L F-, 1 m Cable Lg, BNC
The HACH ISENO3181AP is a nitrate ion selective electrode with a double junction and epoxy body. It measures nitrate concentration from 0.1 mg/L to 14 g/L and includes a 1 m cable. Suitable for direct measurement in aqueous solutions in environmental and water quality testing applications
HACH
The HACH ISENO3181AP is a nitrate ion selective electrode with a double junction and epoxy body. It measures nitrate concentration from 0.1 mg/L to 14 g/L and includes a 1 m cable. Suitable for direct measurement in aqueous solutions in environmental and water quality testing applications
HACH Electrode: ISENO318103, Nitrate, 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N, 3 m Cable Lg
HACH
HACH Electrode: ISENO318103, Nitrate, 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N, 3 m Cable Lg
HACH Electrode: ISENH418101, Ammonium, 0.018 mg/L (10-6M) to 9 g/L (0.5 M) NH4-N, 1 m Cable Lg
HACH
HACH Electrode: ISENH418101, Ammonium, 0.018 mg/L (10-6M) to 9 g/L (0.5 M) NH4-N, 1 m Cable Lg

More from HACH

View all HACH parts
Epoxy-body ammonia ion selective electrode with double annular junction. Measures ammonia concentration from 0.01 mg/L (5 x 10⁻⁷ M) to 14 g/L (1 M). Includes 1 m cable. Used for direct measurement of ammonia in aqueous solutions in laboratory and field applications
HACH
Epoxy-body ammonia ion selective electrode with double annular junction. Measures ammonia concentration from 0.01 mg/L (5 x 10⁻⁷ M) to 14 g/L (1 M). Includes 1 m cable. Used for direct measurement of ammonia in aqueous solutions in laboratory and field applications
Fluoride ion selective electrode with a measurement range of 0.01 mg/L to 19 g/L. Features an annular PTFE junction and epoxy body. Includes a 1 m cable. Suitable for measuring fluoride concentration in aqueous solutions in water quality and industrial process applications
HACH
Fluoride ion selective electrode with a measurement range of 0.01 mg/L to 19 g/L. Features an annular PTFE junction and epoxy body. Includes a 1 m cable. Suitable for measuring fluoride concentration in aqueous solutions in water quality and industrial process applications
Ammonium ion selective electrode with epoxy body and double junction. Measures NH4-N from 0.018 mg/L (10⁻⁶ M) to 9 g/L (0.5 M). Includes 1 m cable. Used for direct measurement of ammonium in aqueous solutions in laboratory and field applications
HACH
Ammonium ion selective electrode with epoxy body and double junction. Measures NH4-N from 0.018 mg/L (10⁻⁶ M) to 9 g/L (0.5 M). Includes 1 m cable. Used for direct measurement of ammonium in aqueous solutions in laboratory and field applications
Glass-body ion selective electrode for measurement of sodium ion concentration in aqueous solutions. Range 0.05 to 23000. Features BNC connector, 1 m cable, 1/2 in diameter. Suitable for laboratory and field water analysis
HACH
Glass-body ion selective electrode for measurement of sodium ion concentration in aqueous solutions. Range 0.05 to 23000. Features BNC connector, 1 m cable, 1/2 in diameter. Suitable for laboratory and field water analysis
Plastic-body ammonium ion selective electrode with double junction. Measures NH4-N from 0.018 mg/L (10⁻⁶ M) to 9 g/L (0.5 M). Includes 3 m cable. Used for ammonium determination in water and wastewater analysis
HACH
Plastic-body ammonium ion selective electrode with double junction. Measures NH4-N from 0.018 mg/L (10⁻⁶ M) to 9 g/L (0.5 M). Includes 3 m cable. Used for ammonium determination in water and wastewater analysis
This ammonium ion selective electrode has a measurement range of 0.018 to 9000 mg/L. It features a PVC body, porous annular PTFE junction, and BNC connector with a 1 m cable. Used for determining ammonium concentration in aqueous solutions
HACH
This ammonium ion selective electrode has a measurement range of 0.018 to 9000 mg/L. It features a PVC body, porous annular PTFE junction, and BNC connector with a 1 m cable. Used for determining ammonium concentration in aqueous solutions
Ion selective electrode for measuring nitrate (NO3-N) in aqueous solutions. Epoxy body with double junction and 1 m cable. Range: 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N. Used in water quality testing, environmental monitoring, and laboratory analysis
HACH
Ion selective electrode for measuring nitrate (NO3-N) in aqueous solutions. Epoxy body with double junction and 1 m cable. Range: 0.1 mg/L (7 x 10-6M) to 14 g/L (1 M) NO3-N. Used in water quality testing, environmental monitoring, and laboratory analysis
Fluoride ion selective electrode with a measurement range of 0.02 mg/L to 20000 mg/L F-. Features a porous annular PTFE junction, epoxy body, and BNC connection with 1 m cable. Used for determining fluoride concentration in aqueous solutions
HACH
Fluoride ion selective electrode with a measurement range of 0.02 mg/L to 20000 mg/L F-. Features a porous annular PTFE junction, epoxy body, and BNC connection with 1 m cable. Used for determining fluoride concentration in aqueous solutions