Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
Image not available
HONEYWELLCalibration Gases for Portable Gas Detectors

HONEYWELL Isobutylene 100 ppm Calibration Gas, 34 L, CGA C10

<p>Ensure your portable gas detectors are accurately calibrated with the Honeywell Isobutylene 100 ppm Calibration Gas. This 34-liter cylinder contains a precise mixture of 100 ppm isobutylene (C4H8) in air, with a…

SKU 3G-OTH-549904

Also listed as: 6101082000 · 610 1082 000

Brand
HONEYWELL
Item
Isobutylene 100 ppm Calibration Gas, 34 L, CGA C10
Part Number
610-1082-000
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

HONEYWELL
Manufacturer Part Number
610-1082-000
Type
C4H8, Calibration Gas, Calibration Gas
CGA Number
CGA C10
Gas Mixture
Isobutylene 100 ppm
Background Gas
Air
Cylinder Capacity
34 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

<p>Ensure your portable gas detectors are accurately calibrated with the Honeywell Isobutylene 100 ppm Calibration Gas. This 34-liter cylinder contains a precise mixture of 100 ppm isobutylene (C4H8) in air, with a CGA C10 fitting for compatibility with Honeywell and other detectors. Ideal for field calibration of photoionization detectors (PIDs) and other instruments that respond to isobutylene.</p><p>As a Singapore-based supplier, 3G Electric offers this calibration gas with convenient SGD quotes, GST handling for local buyers, and fast delivery across Singapore and Southeast Asia. Request a quote today to ensure your equipment stays reliable and compliant.</p>

Frequently Asked Questions

What is the gas mixture and cylinder capacity?

The gas mixture is Isobutylene 100 ppm with air as the background gas. The cylinder capacity is 34 liters.

What is the CGA fitting and how does it affect compatibility?

The CGA number is CGA C10. This fitting is specific to the cylinder valve and must match your regulator or detector connection for proper use.

Used in

Common applications for HONEYWELL
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits
Not sure this is the right part? Photo-identify it

HONEYWELL Products

3G Electric supplies HONEYWELL calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from HONEYWELL

View all HONEYWELL parts
HONEYWELL
HONEYWELL
Calibration gas mixture of 25 ppm nitric oxide in a nitrogen background, supplied in a 58 L cylinder with a CGA C10 connection. Used for verifying the accuracy of portable gas detectors that measure nitric oxide in industrial safety applications
HONEYWELL
HONEYWELL
This calibration gas cylinder contains 5 ppm sulfur dioxide (SO2) in a nitrogen background, with +/-10% accuracy. It is intended for use with gas detection instruments to verify and adjust sensor response. The 58 L cylinder features a CGA C10 connection
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm hydrogen sulfide in nitrogen, supplied in a 58-liter cylinder with a CGA C10 connection. Used to verify and adjust the response of portable gas detectors that sense hydrogen sulfide in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 5 ppm chlorine in nitrogen background, supplied in a 58 L cylinder with CGA C10 fitting. Used to verify and adjust the accuracy of portable gas detectors that sense chlorine
HONEYWELL
HONEYWELL
Calibration gas containing 99.9% nitrogen in a 103 L cylinder with CGA 600 connection. Used for verifying and adjusting the accuracy of portable gas detectors with nitrogen sensors in industrial safety applications
HONEYWELL
HONEYWELL
Aerosol calibration gas containing 100 ppm carbon monoxide in an 11 L cylinder. Designed for verifying and calibrating GasAlert Series Model Carbon Monoxide sensors in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture containing 500 ppm hydrogen in air, supplied in a 103 L cylinder with CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors during routine safety checks
HONEYWELL
HONEYWELL
Calibration gas mixture containing 19% oxygen in a 58 L cylinder with CGA 600 connection. Used for verifying and adjusting the accuracy of portable gas detectors, particularly GasAlert Series Model Methane Sensors in industrial safety applications

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first