Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

HONEYWELL HOME Intermittent Pilot Ignitor - Intermittent Pilot Ignition Controls
HONEYWELL HOMEIntermittent Pilot Ignition Controls

HONEYWELL HOME Intermittent Pilot Ignitor

The HONEYWELL HOME Intermittent Pilot Ignitor (MPN Y8610U4001) is a universal 24V AC ignition control with a 15-second lockout and 30-second pre-purge. It is designed as a replacement for Honeywell OEM brands.

SKU 3G-OTH-68046

Brand
HONEYWELL HOME
Item
Intermittent Pilot Ignitor
Category
Intermittent Pilot Ignition Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

HONEYWELL HOME
Manufacturer Part Number
Y8610U4001
Product Type
Intermittent Pilot Ignitor
Control Voltage
24V AC
Replacement for OEM Brands
Honeywell

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL HOME Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL HOME Intermittent Pilot Ignitor (MPN Y8610U4001) is a universal 24V AC ignition control with a 15-second lockout and 30-second pre-purge. It is designed as a replacement for Honeywell OEM brands.

Frequently Asked Questions

What is the Honeywell Home Y8610U4001 intermittent pilot ignitor used for?

The Honeywell Home Y8610U4001 is a universal 24V AC intermittent pilot ignitor used to control gas ignition in furnaces, boilers, and other heating appliances. It provides a 30-second pre-purge and a 15-second lockout, ensuring safe and reliable ignition in residential and light commercial systems.

What are the specifications of the Honeywell Home Y8610U4001?

The Honeywell Home Y8610U4001 is a 24V AC intermittent pilot ignitor with a 15-second lockout and 30-second pre-purge. It is designed as a universal replacement for Honeywell OEM brands. The product type is Intermittent Pilot Ignition Controls, and the manufacturer part number is Y8610U4001.

Where to buy the Honeywell Home Y8610U4001 worldwide?

You can source the Honeywell Home Y8610U4001 through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we supply genuine Honeywell Home ignition controls for international orders.

How to install the Honeywell Home Y8610U4001 intermittent pilot ignitor?

To install the Honeywell Home Y8610U4001, first disconnect power and gas supply. Mount the ignitor in the appliance control panel, connect 24V AC power leads, and wire the pilot flame sensor per the wiring diagram. Set the pre-purge and lockout timers as required. Always follow local codes and the manufacturer's instructions.

Used in

Common applications for HONEYWELL HOME
Residential HVAC — Honeywell Home TH115-A-120S/U thermostat for 7-day programmable temperature control in homes.
Light commercial buildings — Honeywell Home TL8230A1003 line-voltage thermostat for electric heating systems in offices.
Hydronic heating systems — Honeywell Home L4006E1117 immersion controller for high-limit temperature regulation in boilers.
Indoor air quality monitoring — Honeywell Home C7263A1008 air quality sensor for gas analysis in commercial facilities.
Furnace control — Honeywell Home ST9120U1011 timer controller for circulating fan timing in integrated furnace systems.
HVAC switching — Honeywell Home RA889A1001 switching relay for 24V AC control of zone valves or dampers.

HONEYWELL HOME Products

3G Electric supplies HONEYWELL HOME intermittent pilot ignition controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Universal intermittent pilot ignition control for gas-fired heating systems. Operates at 24V AC with 15-second lockout and 30-second pre-purge. Replaces other OEM brands
RESIDEO
Universal intermittent pilot ignition control for gas-fired heating systems. Operates at 24V AC with 15-second lockout and 30-second pre-purge. Replaces other OEM brands
Universal hot surface ignition module for gas-fired heating equipment. Operates on 120V AC control voltage with a 4-second lockout and 32-second pre-purge timing. Replaces White-Rodgers OEM brands. Controls ignition sequence by energizing a hot surface igniter and monitoring flame presence
HONEYWELL HOME
Universal hot surface ignition module for gas-fired heating equipment. Operates on 120V AC control voltage with a 4-second lockout and 32-second pre-purge timing. Replaces White-Rodgers OEM brands. Controls ignition sequence by energizing a hot surface igniter and monitoring flame presence
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 270-second lockout, 15-second pre-purge, and 1.5 A main valve output. Designed as an OEM replacement for Goodman equipment. Used in gas furnaces to manage ignition sequencing and safety functions
WHITE-RODGERS
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 270-second lockout, 15-second pre-purge, and 1.5 A main valve output. Designed as an OEM replacement for Goodman equipment. Used in gas furnaces to manage ignition sequencing and safety functions
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 15-second pre-purge, 258-second lockout, and 1.5 A main valve output. Suitable for use as an OEM replacement in gas furnaces requiring 120V AC control
WHITE-RODGERS
Integrated furnace control for intermittent pilot ignition systems. Operates at 120V AC control voltage with a 15-second pre-purge, 258-second lockout, and 1.5 A main valve output. Suitable for use as an OEM replacement in gas furnaces requiring 120V AC control
This hot surface ignition module is designed for intermittent pilot ignition control in gas-fired heating equipment. It operates on 18 to 30V AC control voltage, features a 45-second pre-purge and a 687-second lockout time, and provides a 4 A main valve output
WHITE-RODGERS
This hot surface ignition module is designed for intermittent pilot ignition control in gas-fired heating equipment. It operates on 18 to 30V AC control voltage, features a 45-second pre-purge and a 687-second lockout time, and provides a 4 A main valve output
The Robertshaw 780-001 is a universal intermittent pilot ignition control for gas-fired heating equipment. It operates at 24V AC with a 1-minute lockout and 5-minute pre-purge, and provides a 1.5 A main valve output. This control is designed as a replacement for Honeywell OEM brands
Robertshaw
The Robertshaw 780-001 is a universal intermittent pilot ignition control for gas-fired heating equipment. It operates at 24V AC with a 1-minute lockout and 5-minute pre-purge, and provides a 1.5 A main valve output. This control is designed as a replacement for Honeywell OEM brands

More from HONEYWELL HOME

View all HONEYWELL HOME parts
HONEYWELL HOME
HONEYWELL HOME
This integrated furnace control is designed for oil-fired heating systems with intermittent pilot ignition. It operates at 24 V AC control voltage and features a 15-second lockout time. Main valve output ratings are 7.4 A and 3.7 A. Suitable for managing burner operation in residential and light commercial oil heating applications
Intermittent pilot ignition control for gas-fired heating systems. Operates at 24V AC with a 15-second lockout time and 30-second pre-purge period. Main valve output rated at 24 A. Universal replacement for Honeywell OEM brands
HONEYWELL HOME
Intermittent pilot ignition control for gas-fired heating systems. Operates at 24V AC with a 15-second lockout time and 30-second pre-purge period. Main valve output rated at 24 A. Universal replacement for Honeywell OEM brands