Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

HUBBELL KILLARK Fully Configured Fixture: 2,880 lm, T4 Temp Code, 150 W, 120/240V AC - Bulb-Dependent Jelly Jar Hazardous Location Lights
HUBBELL KILLARKBulb-Dependent Jelly Jar Hazardous Location Lights

HUBBELL KILLARK Fully Configured Fixture: 2,880 lm, T4 Temp Code, 150 W, 120/240V AC

The HUBBELL KILLARK Fully Configured Fixture: 2,880 lm is a bulb-dependent jelly jar hazardous location light rated for Class I, Div 1 and 2, Group C, D environments. It operates at 120/240V AC with a T4 temperature…

SKU 3G-OTH-390956

Brand
HUBBELL KILLARK
Item
Fully Configured Fixture: 2,880 lm, T4 Temp Code, 150 W, 120/240V AC
Category
Bulb-Dependent Jelly Jar Hazardous Location Lights
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

HUBBELL KILLARK
Manufacturer Part Number
EMI15X2G
Type
T4 Temp Code, 150 W
AC
120/240V
Ht
14 in
Voltage
120/240V AC
Temperature Code
T4
Emergency Battery Backup
No
Hazardous Location Rating
Class I, Div 1 and 2, Group C, D
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HUBBELL KILLARK Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HUBBELL KILLARK Fully Configured Fixture: 2,880 lm is a bulb-dependent jelly jar hazardous location light rated for Class I, Div 1 and 2, Group C, D environments. It operates at 120/240V AC with a T4 temperature code and a 150 W rating, measuring 14 in height (MPN EMI15X2G). This fixture does not include an emergency battery backup.

Frequently Asked Questions

What is the HUBBELL KILLARK EMI15X2G fixture used for?

The HUBBELL KILLARK EMI15X2G is a bulb-dependent jelly jar hazardous location light used in Class I, Div 1 and 2, Group C, D environments. It provides 2,880 lm of illumination for industrial areas with flammable gases or vapors, such as refineries, chemical plants, and oil rigs.

What are the specifications of the HUBBELL KILLARK EMI15X2G?

The HUBBELL KILLARK EMI15X2G operates at 120/240V AC, has a T4 temperature code, a 150 W rating, and a height of 14 in. It is rated for Class I, Div 1 and 2, Group C, D hazardous locations. This fixture does not include an emergency battery backup.

Where to buy the HUBBELL KILLARK EMI15X2G worldwide?

You can source the HUBBELL KILLARK EMI15X2G through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to install the HUBBELL KILLARK EMI15X2G fixture?

Installation must follow the manufacturer's instructions and local electrical codes. Ensure the fixture is properly grounded and wired for 120/240V AC. Use only approved conduit seals for Class I, Div 1 locations. Always disconnect power before servicing. Consult a qualified electrician.

Used in

Common applications for HUBBELL KILLARK
Oil and gas refineries — Hubbell Killark MM-90-1WW 90° elbows for conduit routing in Class I Division 1 areas
Chemical processing plants — Hubbell Killark SWB-5 device boxes for housing switches and controls in corrosive environments
Grain handling facilities — Hubbell Killark VM1L4530 LED light fixtures for illumination in dust-ignition-proof locations
Pharmaceutical manufacturing — Hubbell Killark GECLBT-1 conduit outlet bodies for wiring connections in clean rooms with hazardous vapors
Wastewater treatment plants — Hubbell Killark GRK-537L enclosures with lens covers for instrument housing in wet hazardous zones
Petrochemical storage terminals — Hubbell Killark OLL-8M iron conduit outlet bodies for heavy-duty conduit systems in outdoor classified areas

HUBBELL KILLARK Products

3G Electric supplies HUBBELL KILLARK bulb-dependent jelly jar hazardous location lights. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
HUBBELL KILLARK
HUBBELL KILLARK
HUBBELL KILLARK Hazardous Location LED Fixture: 6,515 lm, T4A Temp Code, 5000K, 40 W, 277V AC (MPN VML1X530G). Key specifications — attr1259085: 277V AC; attr1259084: T4A; attr1259058: Class II, Div 1 and 2, Group E, F, G; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK
HUBBELL KILLARK
HUBBELL KILLARK Explosion Proof LED Fixture: 5,295 lm, T6 Temp Code, 5000K, 65 W, 277V AC, 22 in Ht (MPN EZL6530). Key specifications — attr1259085: 277V AC; attr1259084: T6; attr1259058: Class II, Div 1 and 2, Group E, F, G; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK Hazardous Location Fixture Combo: 1,625 lm, T5 Temp Code, 5000K, 16 W, 120/277V AC (MPN VSL1630F1HG). Key specifications — attr1259085: 120/277V AC; attr1259084: T5; attr1259058: Class I, Div 2, Group A, B, C, D; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK
HUBBELL KILLARK Hazardous Location Fixture Combo: 1,625 lm, T5 Temp Code, 5000K, 16 W, 120/277V AC (MPN VSL1630F1HG). Key specifications — attr1259085: 120/277V AC; attr1259084: T5; attr1259058: Class I, Div 2, Group A, B, C, D; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK Hazardous Location Fixture Combo: 1,300 lm, T5 Temp Code, 5000K, 13 W, 120/277V AC (MPN VSL1330F1HG). Key specifications — attr1259085: 120/277V AC; attr1259084: T5; attr1259058: Class II, Div 2, Group F, G; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK
HUBBELL KILLARK Hazardous Location Fixture Combo: 1,300 lm, T5 Temp Code, 5000K, 13 W, 120/277V AC (MPN VSL1330F1HG). Key specifications — attr1259085: 120/277V AC; attr1259084: T5; attr1259058: Class II, Div 2, Group F, G; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK Hazardous Location Fixture Combo: 1,625 lm, T5 Temp Code, 5000K, 16 W, 120/277V AC (MPN VSL1630W2HG). Key specifications — attr1259085: 120/277V AC; attr1259084: T5; attr1259058: Class I, Div 2, Group A, B, C, D; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK
HUBBELL KILLARK Hazardous Location Fixture Combo: 1,625 lm, T5 Temp Code, 5000K, 16 W, 120/277V AC (MPN VSL1630W2HG). Key specifications — attr1259085: 120/277V AC; attr1259084: T5; attr1259058: Class I, Div 2, Group A, B, C, D; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.
HUBBELL KILLARK
HUBBELL KILLARK
HUBBELL KILLARK Explosion Proof LED Fixture: 12,720 lm, T6 Temp Code, 5000K, 125 W, 277V AC (MPN EZL12530). Key specifications — attr1259085: 277V AC; attr1259084: T6; attr1259058: Class I, Div 1 and 2, Group C, D; attr1259088: No; attr1259089: 5000K; attr1259106: HUBBELL KILLARK.

More from HUBBELL KILLARK

View all HUBBELL KILLARK parts