HUBBELL KILLARK LZ2SE2-32230 Fluorescent Linear Hazardous - Fluorescent Linear Hazardous Location Light Fixtures
HUBBELL KILLARKFluorescent Linear Hazardous Location Light Fixtures

HUBBELL KILLARK LZ2SE2-32230 Fluorescent Linear Hazardous

The HUBBELL KILLARK LZ2SE2-32230 is a 1,350 lm fluorescent linear hazardous location light fixture rated for Class I, Div 2, Groups A, B, C, D. It operates on 120/277V AC, uses a T8 bulb shape, and carries a T6…

SKU 3G-OTH-387293

Also listed as: LZ2SE232230 · LZ2SE2 32230

Brand
HUBBELL KILLARK
Item
LZ2SE2-32230 Fluorescent Linear Hazardous
Category
Fluorescent Linear Hazardous Location Light Fixtures
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

HUBBELL KILLARK
Manufacturer Part Number
LZ2SE2-32230
Type
T6 Temp Code, 65 W
AC
120/277V
Voltage
120/277V AC
For Bulb Shape
T8
Temperature Code
T6
Hazardous Location Rating
Class I, Div 2, Group A, B, C, D

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HUBBELL KILLARK Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HUBBELL KILLARK LZ2SE2-32230 is a 1,350 lm fluorescent linear hazardous location light fixture rated for Class I, Div 2, Groups A, B, C, D. It operates on 120/277V AC, uses a T8 bulb shape, and carries a T6 temperature code.

Frequently Asked Questions

What is the HUBBELL KILLARK LZ2SE2-32230 used for?

The HUBBELL KILLARK LZ2SE2-32230 is a fluorescent linear hazardous location light fixture designed for use in Class I, Div 2, Groups A, B, C, D environments. It provides 1,350 lm of illumination in areas where flammable gases or vapors may be present, such as oil refineries, chemical plants, and industrial processing facilities.

What are the specifications of the HUBBELL KILLARK LZ2SE2-32230?

The HUBBELL KILLARK LZ2SE2-32230 operates on 120/277V AC, uses a T8 bulb shape, and has a T6 temperature code with 65 W power consumption. It is rated for Class I, Div 2, Groups A, B, C, D hazardous locations and delivers 1,350 lm output. The manufacturer part number is LZ2SE2-32230.

Where to buy HUBBELL KILLARK hazardous location lighting worldwide?

3G Electric supplies the HUBBELL KILLARK LZ2SE2-32230 and other hazardous location lighting fixtures worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this T6 temp code, 65 W fixture.

How to select the right HUBBELL KILLARK hazardous location light fixture?

Select a HUBBELL KILLARK fixture by matching its hazardous location rating (e.g., Class I, Div 2, Groups A, B, C, D) to your area classification. Verify voltage compatibility (120/277V AC), temperature code (T6 for 850 °C max surface temp), and lumen output (1,350 lm). Ensure the T8 bulb shape fits your installation requirements.

Used in

Common applications for HUBBELL KILLARK
Oil and gas refineries — Hubbell Killark MM-90-1WW 90° elbows for conduit routing in Class I Division 1 areas
Chemical processing plants — Hubbell Killark SWB-5 device boxes for housing switches and controls in corrosive environments
Grain handling facilities — Hubbell Killark VM1L4530 LED light fixtures for illumination in dust-ignition-proof locations
Pharmaceutical manufacturing — Hubbell Killark GECLBT-1 conduit outlet bodies for wiring connections in clean rooms with hazardous vapors
Wastewater treatment plants — Hubbell Killark GRK-537L enclosures with lens covers for instrument housing in wet hazardous zones
Petrochemical storage terminals — Hubbell Killark OLL-8M iron conduit outlet bodies for heavy-duty conduit systems in outdoor classified areas

HUBBELL KILLARK Products

3G Electric supplies HUBBELL KILLARK fluorescent linear hazardous location light fixtures. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 1 and 2, Groups B, C, D. It delivers 8,919 lumens at 5000K color temperature with a T6 temperature code. The fixture operates on 120/277V AC, consumes 80.4W, and is surface mounted. Suitable for industrial environments where flammable gases or vapors may be present
HUBBELL KILLARK
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 1 and 2, Groups B, C, D. It delivers 8,919 lumens at 5000K color temperature with a T6 temperature code. The fixture operates on 120/277V AC, consumes 80.4W, and is surface mounted. Suitable for industrial environments where flammable gases or vapors may be present
LED linear light fixture for hazardous locations, rated Class I, Div 1 and 2, Groups B, C, D. Operates on 120/277V AC, 46.5 W, 5000K, 5598 lumens, T6 temperature code. Surface mount installation. Suitable for areas with flammable gases or vapors
HUBBELL KILLARK
LED linear light fixture for hazardous locations, rated Class I, Div 1 and 2, Groups B, C, D. Operates on 120/277V AC, 46.5 W, 5000K, 5598 lumens, T6 temperature code. Surface mount installation. Suitable for areas with flammable gases or vapors
Surface-mount LED linear light fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, 46.5 W, producing 5,598 lumens at 5000K with T6 temperature code. Suitable for areas with combustible fibers or flyings
HUBBELL KILLARK
Surface-mount LED linear light fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, 46.5 W, producing 5,598 lumens at 5000K with T6 temperature code. Suitable for areas with combustible fibers or flyings
Fluorescent light tank for hazardous locations, rated 84W with 4000K color temperature and T2B temperature code. Operates on 120-277V AC and measures 14 1/16 inches in length. Suspended mounting style, not color selectable. Suitable for areas where flammable gases, vapors, or combustible dusts may be present
HUBBELL KILLARK
Fluorescent light tank for hazardous locations, rated 84W with 4000K color temperature and T2B temperature code. Operates on 120-277V AC and measures 14 1/16 inches in length. Suspended mounting style, not color selectable. Suitable for areas where flammable gases, vapors, or combustible dusts may be present
LED linear light fixture for hazardous locations rated Class II, Div 1 and 2, Groups E, F, G. Operates at 120/277V AC, 28 W, 5000K color temperature, T5 temperature code. Surface mount, 3 ft length, 3321 lumens output. Suitable for areas with combustible dusts
HUBBELL KILLARK
LED linear light fixture for hazardous locations rated Class II, Div 1 and 2, Groups E, F, G. Operates at 120/277V AC, 28 W, 5000K color temperature, T5 temperature code. Surface mount, 3 ft length, 3321 lumens output. Suitable for areas with combustible dusts
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 2, Groups A, B, C, D. It delivers 7,064 lumens at 5000K color temperature, operates on 120/277V AC, and consumes 60 W. The fixture has a T5 temperature code, is surface-mounted, and measures 3 ft in length. Suitable for environments where flammable gases or vapors may be present
HUBBELL KILLARK
This LED linear light fixture is designed for hazardous locations classified as Class I, Division 2, Groups A, B, C, D. It delivers 7,064 lumens at 5000K color temperature, operates on 120/277V AC, and consumes 60 W. The fixture has a T5 temperature code, is surface-mounted, and measures 3 ft in length. Suitable for environments where flammable gases or vapors may be present

More from HUBBELL KILLARK

View all HUBBELL KILLARK parts
Fluorescent linear light fixture rated for Class I, Division 2, Groups A, B, C, D hazardous locations. Operates on 120/277V AC, uses T8 bulbs, and carries a T6 temperature code. Suitable for areas where flammable gases or vapors may be present
HUBBELL KILLARK
Fluorescent linear light fixture rated for Class I, Division 2, Groups A, B, C, D hazardous locations. Operates on 120/277V AC, uses T8 bulbs, and carries a T6 temperature code. Suitable for areas where flammable gases or vapors may be present
Fluorescent linear light fixture for hazardous locations rated Class I, Division 2, Groups A, B, C, D. Operates at 120/277V AC, uses T8 bulbs, and has a T6 temperature code with 65 W power consumption. Suitable for areas where flammable gases or vapors may be present
HUBBELL KILLARK
Fluorescent linear light fixture for hazardous locations rated Class I, Division 2, Groups A, B, C, D. Operates at 120/277V AC, uses T8 bulbs, and has a T6 temperature code with 65 W power consumption. Suitable for areas where flammable gases or vapors may be present
Fluorescent linear fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, uses T5HO bulbs, and has a T5 temperature code. Suitable for areas with combustible fibers or flyings
HUBBELL KILLARK
Fluorescent linear fixture rated for Class III, Div 1 and 2 hazardous locations. Operates on 120/277V AC, uses T5HO bulbs, and has a T5 temperature code. Suitable for areas with combustible fibers or flyings