JOHNSON CONTROLS Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise - Single-Pressure Controls
JOHNSON CONTROLSSingle-Pressure Controls

JOHNSON CONTROLS Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise

The JOHNSON CONTROLS Single Pressure Control: High Limit (MPN P170KA-1C) is a single-pressure control with a manual reset, featuring an SPST contact form and a switch action of Open on Rise. It is rated for 208/240V…

SKU 3G-OTH-69507

Also listed as: P170KA1C · P170KA 1C

Brand
JOHNSON CONTROLS
Item
Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise
Category
Single-Pressure Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

JOHNSON CONTROLS
Manufacturer Part Number
P170KA-1C
Type
Manual Reset, 50 psi to 500 psi, Open on Rise, SPST
Contact Form
SPST
Rated Voltage
208/240V AC
Switch Action
Open on Rise

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

JOHNSON CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The JOHNSON CONTROLS Single Pressure Control: High Limit (MPN P170KA-1C) is a single-pressure control with a manual reset, featuring an SPST contact form and a switch action of Open on Rise. It is rated for 208/240V AC and operates within a 50 psi to 500 psi range.

Frequently Asked Questions

What is the Johnson Controls P170KA-1C single pressure control used for?

The Johnson Controls P170KA-1C is a high-limit single pressure control used in industrial refrigeration, HVAC, and process systems to protect compressors and pressure vessels by opening the circuit on a pressure rise between 50 psi and 500 psi.

What are the specifications of the Johnson Controls P170KA-1C?

The Johnson Controls P170KA-1C is a manual reset, open-on-rise SPST pressure control rated for 208/240V AC. It operates from 50 psi to 500 psi and is designed for high-limit safety shutdown in refrigeration and HVAC applications.

Where to buy the Johnson Controls P170KA-1C worldwide?

3G Electric supplies the Johnson Controls P170KA-1C single pressure control worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this manual reset, 50 psi to 500 psi SPST control.

How to install a Johnson Controls P170KA-1C manual reset pressure control?

Install the Johnson Controls P170KA-1C in a dry location, connect to the pressure source via a 1/4" flare fitting, and wire the SPST contacts for 208/240V AC. After a high-pressure trip, manually reset the control by pressing the button once the fault is cleared.

Used in

Common applications for JOHNSON CONTROLS
Industrial refrigeration — Johnson Controls P170SA-1C dual pressure control for compressor protection in ammonia or halocarbon systems
Chiller plant automation — Johnson Controls VA7810-HGA-2 electric globe valve actuator for modulating chilled water flow in VG7000 series valves
Pneumatic HVAC retrofit — Johnson Controls T-4002-302 conversion kit for upgrading existing Robertshaw thermostats in commercial buildings
Cooling tower water management — Johnson Controls V-4332-1007 pneumatically actuated diaphragm valve for 3-way diverting of water flow
Boiler fuel oil pressure monitoring — Johnson Controls P545NCB-25C electronic lube oil pressure control with alarm for burner management systems
Process pressure sensing — Johnson Controls P599AAPS105C pressure transmitter with IP67 rating for washdown zones in food and beverage plants

JOHNSON CONTROLS Products

3G Electric supplies JOHNSON CONTROLS single-pressure controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P170DA-1C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P170DA-1C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-1C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-1C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-3C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-3C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-7C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-7C)

More from JOHNSON CONTROLS

View all JOHNSON CONTROLS parts
Single Pressure Control: Low Limit, Manual Reset, 20 in Hg to 100 psi, Open on Fall, SPST (MPN P70BA-1C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Manual Reset, 20 in Hg to 100 psi, Open on Fall, SPST (MPN P70BA-1C)
High Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P70DA-400C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P70DA-400C)
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
Pressure Cut-Out Control: High Limit, Manual Reset, 400 psi to 600 psi, Open on Rise, SPST (MPN P20DA-116C)
JOHNSON CONTROLS
Pressure Cut-Out Control: High Limit, Manual Reset, 400 psi to 600 psi, Open on Rise, SPST (MPN P20DA-116C)
Single Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P170CA-3C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P170CA-3C)
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P170CA-1C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P170CA-1C)
Single Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P170DA-400C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Manual Reset, 200 psi to 610 psi, Open on Rise, SPST (MPN P170DA-400C)
High Pressure Control: Fan Cycling, Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-400C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-400C)