Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

JOHNSON CONTROLS High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi - Single-Pressure Controls
JOHNSON CONTROLSSingle-Pressure Controls

JOHNSON CONTROLS High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi

The JOHNSON CONTROLS P70CA-2C is a High Pressure Control: High Limit, categorized as a Single-Pressure Control. It features an SPST contact form, a rated voltage of 120V AC, and a switch action of Open on Rise. The…

SKU 3G-OTH-69112

Also listed as: P70CA2C · P70CA 2C

Brand
JOHNSON CONTROLS
Item
High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi
Category
Single-Pressure Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

JOHNSON CONTROLS
Manufacturer Part Number
P70CA-2C
Type
Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise
Contact Form
SPST
Rated Voltage
120V AC
Switch Action
Open on Rise

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

JOHNSON CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The JOHNSON CONTROLS P70CA-2C is a High Pressure Control: High Limit, categorized as a Single-Pressure Control. It features an SPST contact form, a rated voltage of 120V AC, and a switch action of Open on Rise. The control has an auto reset and operates within a pressure range of 50 psi to 500 psi, with a differential of 60 psi to 150 psi.

Frequently Asked Questions

What is the JOHNSON CONTROLS P70CA-2C high pressure control used for?

The JOHNSON CONTROLS P70CA-2C is a high-limit single-pressure control used in HVAC and refrigeration systems to protect compressors from excessive pressure. It opens the circuit on pressure rise and auto-resets when pressure drops, preventing system damage.

What are the specifications of the JOHNSON CONTROLS P70CA-2C?

The JOHNSON CONTROLS P70CA-2C is a SPST high-pressure control rated at 120V AC with open-on-rise switch action. It has an adjustable range of 50 psi to 500 psi and a differential of 60 psi to 150 psi. The control features auto reset for reliable operation.

Where to buy JOHNSON CONTROLS P70CA-2C worldwide?

3G Electric supplies the JOHNSON CONTROLS P70CA-2C worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this single-pressure control.

How to install the JOHNSON CONTROLS P70CA-2C high pressure control?

Install the JOHNSON CONTROLS P70CA-2C by mounting it securely in the refrigeration line, connecting the SPST contacts to the 120V AC circuit, and setting the cut-out pressure within the 50–500 psi range. Always follow local electrical codes and system manufacturer guidelines.

Used in

Common applications for JOHNSON CONTROLS
Industrial refrigeration — Johnson Controls P170SA-1C dual pressure control for compressor protection in ammonia or halocarbon systems
Chiller plant automation — Johnson Controls VA7810-HGA-2 electric globe valve actuator for modulating chilled water flow in VG7000 series valves
Pneumatic HVAC retrofit — Johnson Controls T-4002-302 conversion kit for upgrading existing Robertshaw thermostats in commercial buildings
Cooling tower water management — Johnson Controls V-4332-1007 pneumatically actuated diaphragm valve for 3-way diverting of water flow
Boiler fuel oil pressure monitoring — Johnson Controls P545NCB-25C electronic lube oil pressure control with alarm for burner management systems
Process pressure sensing — Johnson Controls P599AAPS105C pressure transmitter with IP67 rating for washdown zones in food and beverage plants

JOHNSON CONTROLS Products

3G Electric supplies JOHNSON CONTROLS single-pressure controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-3C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Auto Reset, 50 psi to 500 psi, 60 psi to 150 psi, Open on Rise (MPN P70CA-3C)
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-1C)
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-4C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Rise (MPN P70CA-4C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-1C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Close on Rise/Open on Rise, SPST (MPN P70KA-1C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)

More from JOHNSON CONTROLS

View all JOHNSON CONTROLS parts
High Pressure Control: Fan Cycling, Auto Reset, 50 psi to 300 psi, 20 psi to 120 psi, Open on Fall (MPN P70AA-119C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 50 psi to 300 psi, 20 psi to 120 psi, Open on Fall (MPN P70AA-119C)
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 475 psi, 35 psi to 200 psi, Open on Fall (MPN P72AA-27C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 475 psi, 35 psi to 200 psi, Open on Fall (MPN P72AA-27C)
Low Pressure Control: Low Limit, Auto Reset, 100 psi to 100 psi, 7 psi to 50 psi, Open on Fall, SPST (MPN P70AB-2CQ)
JOHNSON CONTROLS
Low Pressure Control: Low Limit, Auto Reset, 100 psi to 100 psi, 7 psi to 50 psi, Open on Fall, SPST (MPN P70AB-2CQ)
Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P170KA-1C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P170KA-1C)
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, SPST (MPN P70GA-11C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, SPST (MPN P70GA-11C)
Single Pressure Control: High or Low Limit, Auto Reset, 0 psi to 750 psi, 5 psi to 20 psi, SPDT (MPN P470FB-1C)
JOHNSON CONTROLS
Single Pressure Control: High or Low Limit, Auto Reset, 0 psi to 750 psi, 5 psi to 20 psi, SPDT (MPN P470FB-1C)
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 400 psi, 35 psi to 200 psi, Open on Fall (MPN P70AA-118C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 400 psi, 35 psi to 200 psi, Open on Fall (MPN P70AA-118C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, 35 psi to 200 psi, Close on Rise (MPN P70KA-7)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, 35 psi to 200 psi, Close on Rise (MPN P70KA-7)