Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

JOHNSON CONTROLS High Pressure Control: Fan Cycling, Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi - Single-Pressure Controls
JOHNSON CONTROLSSingle-Pressure Controls

JOHNSON CONTROLS High Pressure Control: Fan Cycling, Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi

The JOHNSON CONTROLS High Pressure Control: Fan Cycling (SKU 3G-OTH-69383, MPN P70CA-400C) is a single-pressure control with an SPST contact form, rated for 120V AC. Its switch action is Open on Rise, with an auto…

SKU 3G-OTH-69383

Also listed as: P70CA400C · P70CA 400C

Brand
JOHNSON CONTROLS
Item
High Pressure Control: Fan Cycling, Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi
Category
Single-Pressure Controls
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

JOHNSON CONTROLS
Manufacturer Part Number
P70CA-400C
Type
Auto Reset, 200 psi to 610 psi, 60 psi to 150 psi, Open on Rise
Contact Form
SPST
Rated Voltage
120V AC
Switch Action
Open on Rise

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

JOHNSON CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The JOHNSON CONTROLS High Pressure Control: Fan Cycling (SKU 3G-OTH-69383, MPN P70CA-400C) is a single-pressure control with an SPST contact form, rated for 120V AC. Its switch action is Open on Rise, with an auto reset and a pressure range of 200 psi to 610 psi and 60 psi to 150 psi.

Frequently Asked Questions

What is the Johnson Controls P70CA-400C high pressure control used for?

The Johnson Controls P70CA-400C is a single-pressure control used for fan cycling in HVAC and refrigeration systems. It opens on rise to protect equipment from overpressure, with auto reset and a pressure range of 200 psi to 610 psi and 60 psi to 150 psi.

What are the specifications of the Johnson Controls P70CA-400C?

The Johnson Controls P70CA-400C is an SPST contact form, rated for 120V AC, with switch action Open on Rise. It features auto reset and a pressure range of 200 psi to 610 psi and 60 psi to 150 psi. The manufacturer part number is P70CA-400C.

Where to buy the Johnson Controls P70CA-400C worldwide?

3G Electric supplies the Johnson Controls P70CA-400C high pressure control to customers worldwide. We handle full logistics, customs clearance, and delivery, ensuring you receive the genuine part regardless of your location. Contact us for availability and lead time.

How to install the Johnson Controls P70CA-400C high pressure control?

Install the Johnson Controls P70CA-400C by mounting it securely in the refrigeration line, ensuring the pressure sensing port is properly connected. Wire the SPST contacts for 120V AC, following the Open on Rise action. Always consult the manufacturer's manual for specific torque and electrical ratings.

Used in

Common applications for JOHNSON CONTROLS
Industrial refrigeration — Johnson Controls P170SA-1C dual pressure control for compressor protection in ammonia or halocarbon systems
Chiller plant automation — Johnson Controls VA7810-HGA-2 electric globe valve actuator for modulating chilled water flow in VG7000 series valves
Pneumatic HVAC retrofit — Johnson Controls T-4002-302 conversion kit for upgrading existing Robertshaw thermostats in commercial buildings
Cooling tower water management — Johnson Controls V-4332-1007 pneumatically actuated diaphragm valve for 3-way diverting of water flow
Boiler fuel oil pressure monitoring — Johnson Controls P545NCB-25C electronic lube oil pressure control with alarm for burner management systems
Process pressure sensing — Johnson Controls P599AAPS105C pressure transmitter with IP67 rating for washdown zones in food and beverage plants

JOHNSON CONTROLS Products

3G Electric supplies JOHNSON CONTROLS single-pressure controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 470 psi, 35 psi to 200 psi, Open on Fall (MPN P70AA-400C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 470 psi, 35 psi to 200 psi, Open on Fall (MPN P70AA-400C)
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 400 psi, 35 psi to 200 psi, Open on Fall (MPN P70AA-118C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 400 psi, 35 psi to 200 psi, Open on Fall (MPN P70AA-118C)
High Pressure Control: Fan Cycling, Auto Reset, 50 psi to 300 psi, 20 psi to 120 psi, Open on Fall (MPN P70AA-119C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 50 psi to 300 psi, 20 psi to 120 psi, Open on Fall (MPN P70AA-119C)
High Pressure Control: Fan Cycling, Auto Reset, 0 psi to 150 psi, 10 psi to 70 psi, Open on Fall (MPN P70AA-2C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 0 psi to 150 psi, 10 psi to 70 psi, Open on Fall (MPN P70AA-2C)
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 475 psi, 35 psi to 200 psi, Open on Fall (MPN P72AA-27C)
JOHNSON CONTROLS
High Pressure Control: Fan Cycling, Auto Reset, 100 psi to 475 psi, 35 psi to 200 psi, Open on Fall (MPN P72AA-27C)
Single Pressure Control: Fan Cycling, Auto Reset, 0 psi to 150 psi, 10 psi to 70 psi, Open on Fall (MPN P170AA-2C)
JOHNSON CONTROLS
Single Pressure Control: Fan Cycling, Auto Reset, 0 psi to 150 psi, 10 psi to 70 psi, Open on Fall (MPN P170AA-2C)

More from JOHNSON CONTROLS

View all JOHNSON CONTROLS parts
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-1C)
Single Pressure Control: Fan Cycling, Auto Reset, 100 psi to 470 psi, 35 psi to 200 psi, SPST (MPN P170AA-400C)
JOHNSON CONTROLS
Single Pressure Control: Fan Cycling, Auto Reset, 100 psi to 470 psi, 35 psi to 200 psi, SPST (MPN P170AA-400C)
Pressure Cut-Out Control: High or Low Limit, Auto Reset, 7 psi to 250 psi, 30 psi, Open on Fall (MPN P20EB-1C)
JOHNSON CONTROLS
Pressure Cut-Out Control: High or Low Limit, Auto Reset, 7 psi to 250 psi, 30 psi, Open on Fall (MPN P20EB-1C)
Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P170DA-1C)
JOHNSON CONTROLS
Single Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P170DA-1C)
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)
JOHNSON CONTROLS
High Pressure Control: High Limit, Manual Reset, 50 psi to 500 psi, Open on Rise, SPST (MPN P70DA-2C)
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P170AB-2C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 20 in Hg to 100 psi, 7 psi to 50 psi, Open on Fall (MPN P170AB-2C)
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P70AB-12C)
JOHNSON CONTROLS
Single Pressure Control: Low Limit, Auto Reset, 12 in Hg to 80 psi, 5 psi to 35 psi, Open on Fall (MPN P70AB-12C)
Single Pressure Control: Fan Cycling, Auto Reset, 100 psi to 400 psi, 35 psi to 200 psi, SPST (MPN P170AA-118C)
JOHNSON CONTROLS
Single Pressure Control: Fan Cycling, Auto Reset, 100 psi to 400 psi, 35 psi to 200 psi, SPST (MPN P170AA-118C)