LAXCO RHB-62 Analog Handheld Refractometer, 28-62% Brix, +/-0.2% Accuracy - Analog Handheld Refractometers
LAXCOAnalog Handheld Refractometers

LAXCO RHB-62 Analog Handheld Refractometer, 28-62% Brix, +/-0.2% Accuracy

<p>The LAXCO RHB-62 is a reliable analog handheld refractometer designed for measuring Brix concentrations in the range of 28-62%. With an accuracy of ±0.2% and a resolution of 0.2% Brix, this manual instrument…

SKU 3G-OTH-377200

Also listed as: RHB62 · RHB 62

Brand
LAXCO
Item
RHB-62 Analog Handheld Refractometer, 28-62% Brix, +/-0.2% Accuracy
Part Number
RHB-62
Category
Analog Handheld Refractometers
Available to Order
Also known as:RHB-62LAXCO
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

LAXCO
Manufacturer Part Number
RHB-62
Type
+/-0.2% Accuracy, Manual, Analog
Accuracy
+/-0.2 %
Overall Dp
7 1/2 in
Resolution
0.2% Brix
Test Parameters
Brix
INC Refractometer
Brix
Refractive Index - Max
62 % Brix
Refractive Index - Min
28 % Brix
Automatic Temperature Compensation Included
Manual

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

LAXCO Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

<p>The LAXCO RHB-62 is a reliable analog handheld refractometer designed for measuring Brix concentrations in the range of 28-62%. With an accuracy of ±0.2% and a resolution of 0.2% Brix, this manual instrument provides precise readings for quality control in food and beverage, agriculture, and industrial applications. Its sturdy construction and easy-to-read scale make it a practical choice for field or lab use.</p><p>As a Singapore-based supplier, 3G Electric offers this refractometer with worldwide shipping. Request an SGD quote for competitive pricing, and enjoy GST handling for local buyers. For customers in Singapore and Southeast Asia, we provide fast delivery to keep your operations running smoothly.</p>

Frequently Asked Questions

What is the measurement range and accuracy of the LAXCO RHB-62?

The LAXCO RHB-62 measures Brix from 28% to 62% with an accuracy of ±0.2% and a resolution of 0.2% Brix.

Does the RHB-62 have automatic temperature compensation?

No, the RHB-62 is a manual refractometer; it does not include automatic temperature compensation.

Not sure this is the right part? Photo-identify it

LAXCO Products

3G Electric supplies LAXCO analog handheld refractometers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from LAXCO

View all LAXCO parts
Analog handheld refractometer for measuring refractive index, serum protein, and specific gravity (urine). Accuracy ±0.0005, resolution 0.001 SG, with automatic temperature compensation. Used in clinical and veterinary settings for rapid fluid analysis
LAXCO
Analog handheld refractometer for measuring refractive index, serum protein, and specific gravity (urine). Accuracy ±0.0005, resolution 0.001 SG, with automatic temperature compensation. Used in clinical and veterinary settings for rapid fluid analysis
Analog handheld refractometer for measuring ethylene glycol concentration. Provides specific gravity readings with ±0.01 SG accuracy and 0.01 SG resolution. Includes automatic temperature compensation. Suitable for field testing of antifreeze and cooling system fluids
LAXCO
Analog handheld refractometer for measuring ethylene glycol concentration. Provides specific gravity readings with ±0.01 SG accuracy and 0.01 SG resolution. Includes automatic temperature compensation. Suitable for field testing of antifreeze and cooling system fluids
Analog handheld refractometer for measuring Brix concentration in liquids. Covers 0% to 32% Brix with +/-0.1% accuracy and 0.2% resolution. Includes automatic temperature compensation. Dimensions: 9 in depth x 1.5 in width. Suitable for field or lab use in quality control and fluid analysis
LAXCO
Analog handheld refractometer for measuring Brix concentration in liquids. Covers 0% to 32% Brix with +/-0.1% accuracy and 0.2% resolution. Includes automatic temperature compensation. Dimensions: 9 in depth x 1.5 in width. Suitable for field or lab use in quality control and fluid analysis