Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

LENNOX Fixed Set-Point Air Pressure Switch - Fixed Set-Point Air Pressure Switches
LENNOXFixed Set-Point Air Pressure Switches

LENNOX Fixed Set-Point Air Pressure Switch

The LENNOX Fixed Set-Point Air Pressure Switch (SKU 57W79, MPN 57W79) is a fixed, auto-reset, open-mounted SPST switch with a 1/4 in barb sample line connection. It operates at 24V AC switch voltage.

SKU 3G-OTH-69269

Brand
LENNOX
Item
Fixed Set-Point Air Pressure Switch
Category
Fixed Set-Point Air Pressure Switches
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

LENNOX
Manufacturer Part Number
57W79
Type
Auto Reset, Open Mounted, SPST, Barb
Switch Voltage
24V AC
Sample Line Connection Size
1/4 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

LENNOX Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The LENNOX Fixed Set-Point Air Pressure Switch (SKU 57W79, MPN 57W79) is a fixed, auto-reset, open-mounted SPST switch with a 1/4 in barb sample line connection. It operates at 24V AC switch voltage.

Frequently Asked Questions

What is a LENNOX 57W79 pressure switch used for?

The LENNOX 57W79 fixed set-point air pressure switch monitors air pressure in HVAC systems. It automatically resets and opens when pressure drops, protecting equipment like furnaces and air handlers. 3G Electric supplies this SPST switch with a 1/4 in barb connection for reliable pressure sensing.

What are the specifications of the LENNOX 57W79 pressure switch?

The LENNOX 57W79 is a fixed, auto-reset, open-mounted SPST pressure switch with a 1/4 in barb sample line connection. It operates at 24V AC switch voltage. The manufacturer part number is 57W79, and it is designed for fixed set-point air pressure applications.

Where to buy a LENNOX 57W79 pressure switch worldwide?

3G Electric supplies the LENNOX 57W79 pressure switch worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source genuine LENNOX parts like this fixed set-point switch for HVAC and combustion systems.

How to install a LENNOX 57W79 fixed pressure switch?

Mount the LENNOX 57W79 in an open position with the 1/4 in barb connection facing the sample line. Connect the 24V AC circuit to the SPST terminals. Ensure the switch resets automatically after pressure normalizes. Always follow OEM guidelines for safe installation and testing.

Used in

Common applications for LENNOX
Commercial HVAC maintenance — Lennox blower wheel 31G67 for replacing worn fans in rooftop units
Gas furnace repair — Lennox induced draft blower 56W68 for exhaust system replacement in residential furnaces
Thermostat upgrade — Lennox 24Z12 for manual control in heat and cool applications in office buildings
Safety system replacement — Lennox limit switch 26G78 for over-temperature protection in industrial heaters
Heat exchanger retrofit — Lennox heat exchanger assembly 96L74 for furnace repair in manufacturing facilities

LENNOX Products

3G Electric supplies LENNOX fixed set-point air pressure switches. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MODINE
MODINE
Fixed set-point air pressure switch with auto reset, designed for monitoring air pressure in HVAC and combustion systems. Features a 1.15 in wc set point, SPST switch action, and 24V switch voltage. Standard housing with 1/4 in push-on terminals for easy installation
This fixed set-point air pressure switch features an auto-reset, open-mounted design with a single-pole single-throw (SPST) configuration. It operates at 24V AC and includes a 1/4-inch barbed sample line connection. Commonly used in HVAC and air-handling systems for monitoring duct or line pressure
CARRIER
This fixed set-point air pressure switch features an auto-reset, open-mounted design with a single-pole single-throw (SPST) configuration. It operates at 24V AC and includes a 1/4-inch barbed sample line connection. Commonly used in HVAC and air-handling systems for monitoring duct or line pressure
Fixed set-point air pressure switch with auto reset, SPDT switching, and barb connection. Set point of 0.05 in wc, rated for 277V AC. Open mounted. Used for low air pressure or airflow detection in HVAC systems, fume hoods, and industrial ventilation
CLEVELAND CONTROLS
Fixed set-point air pressure switch with auto reset, SPDT switching, and barb connection. Set point of 0.05 in wc, rated for 277V AC. Open mounted. Used for low air pressure or airflow detection in HVAC systems, fume hoods, and industrial ventilation
Auto reset adjustable set-point air pressure switch with SPDT push-on contacts. Range 0.1 in wc to 10 in wc, open mounted, rated 277V AC. Used in HVAC duct static pressure, combustion air, and ventilation monitoring
CLEVELAND CONTROLS
Auto reset adjustable set-point air pressure switch with SPDT push-on contacts. Range 0.1 in wc to 10 in wc, open mounted, rated 277V AC. Used in HVAC duct static pressure, combustion air, and ventilation monitoring
Fixed set-point air pressure switch with auto reset function. SPST switch rated at 115V AC, set point of 0.05 in wc. Features a 1/4 in barb connection and conduit box enclosure. Used in HVAC systems to monitor air pressure and control fan or damper operation
TJERNLUND
Fixed set-point air pressure switch with auto reset function. SPST switch rated at 115V AC, set point of 0.05 in wc. Features a 1/4 in barb connection and conduit box enclosure. Used in HVAC systems to monitor air pressure and control fan or damper operation
Auto reset air pressure switch with SPST contact form. Adjustable set-point range of 1 in wc to 12 in wc. Conduit box enclosure with integral compression connection. Switch voltage 120 to 277V AC. Used in HVAC ducts, furnaces, and ventilation systems to monitor air pressure and control equipment
Siemens
Auto reset air pressure switch with SPST contact form. Adjustable set-point range of 1 in wc to 12 in wc. Conduit box enclosure with integral compression connection. Switch voltage 120 to 277V AC. Used in HVAC ducts, furnaces, and ventilation systems to monitor air pressure and control equipment

More from LENNOX

View all LENNOX parts