Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

MADISON Closed Liquid Level Switch: Close On Rise, SPST - Vertically Mounted Float Switches
MADISONVertically Mounted Float Switches

MADISON Closed Liquid Level Switch: Close On Rise, SPST

The MADISON Closed Liquid Level Switch (MPN M7000-PBT-ULL-NO) is a vertically mounted float switch with a SPST, close-on-rise contact configuration. It features a PBT housing and lead wire electrical connection, with…

SKU 3G-OTH-30820

Also listed as: M7000PBTULLNO · M7000 PBT ULL NO

Brand
MADISON
Item
Closed Liquid Level Switch: Close On Rise, SPST
Category
Vertically Mounted Float Switches
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

MADISON
Manufacturer Part Number
M7000-PBT-ULL-NO
Electrical Connection Type
Lead Wires
Minimum Media Specific Gravity
0.56

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MADISON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MADISON Closed Liquid Level Switch (MPN M7000-PBT-ULL-NO) is a vertically mounted float switch with a SPST, close-on-rise contact configuration. It features a PBT housing and lead wire electrical connection, with a minimum media specific gravity of 0.56.

Frequently Asked Questions

What is the MADISON M7000-PBT-ULL-NO liquid level switch used for?

The MADISON M7000-PBT-ULL-NO is a vertically mounted float switch used to detect liquid levels in tanks or vessels. It closes its SPST circuit on rising liquid, making it suitable for high-level alarms or pump control in water, chemical, or industrial fluid applications.

What are the specifications of the MADISON M7000-PBT-ULL-NO?

This MADISON switch has a SPST close-on-rise contact, PBT housing, and lead wire electrical connection. It requires a minimum media specific gravity of 0.56 to operate. The MPN is M7000-PBT-ULL-NO, and it is designed for vertical mounting.

Where to buy the MADISON M7000-PBT-ULL-NO worldwide?

3G Electric supplies the MADISON M7000-PBT-ULL-NO worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install a MADISON vertical float switch?

Mount the MADISON M7000-PBT-ULL-NO vertically in the tank wall or top, ensuring the float moves freely. Connect the lead wires to your control circuit per the SPST close-on-rise wiring. Verify the media specific gravity meets the 0.56 minimum for proper float actuation.

Used in

Common applications for MADISON
Industrial tank level monitoring — MADISON M4400-ULL-NO vertically mounted float switch for high-level alarm in water storage tanks
Pump control in wastewater systems — MADISON M4168-1 side-mounted float switch for automatic pump start/stop in sump pits
Hydraulic system flow verification — MADISON FS8000-20003 piston flow switch for detecting flow in lubrication lines
Chemical processing level sensing — MADISON M3827-3NO stainless steel float switch for corrosive liquid level detection
Non-contact level measurement in bulk storage — MADISON U5098-D024-019 ultrasonic sensor for tank level monitoring up to 19 ft
Cooling water flow monitoring — MADISON FS8000-10010 compact flow switch for verifying coolant flow in heat exchangers

MADISON Products

3G Electric supplies MADISON vertically mounted float switches. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

More from MADISON

View all MADISON parts
Vertically mounted float switch with selectable SPST stainless steel design. Electrical connection via lead wires. Requires minimum media specific gravity of 0.63. Used for liquid level detection and control in tanks, reservoirs, and process vessels
MADISON
Vertically mounted float switch with selectable SPST stainless steel design. Electrical connection via lead wires. Requires minimum media specific gravity of 0.63. Used for liquid level detection and control in tanks, reservoirs, and process vessels
Vertically mounted float switch with a PBT body and lead wires for electrical connection. Provides SPST switching for liquid level detection in tanks or vessels. Suitable for media with a minimum specific gravity of 0.56, such as water, oils, or chemicals
MADISON
Vertically mounted float switch with a PBT body and lead wires for electrical connection. Provides SPST switching for liquid level detection in tanks or vessels. Suitable for media with a minimum specific gravity of 0.56, such as water, oils, or chemicals
Vertically mounted float switch with polypropylene construction. Features SPST normally open contact that closes on rising liquid level. Electrical connection via lead wires. Requires minimum media specific gravity of 0.75. Suitable for level detection in tanks or vessels containing water, oils, or chemicals
MADISON
Vertically mounted float switch with polypropylene construction. Features SPST normally open contact that closes on rising liquid level. Electrical connection via lead wires. Requires minimum media specific gravity of 0.75. Suitable for level detection in tanks or vessels containing water, oils, or chemicals
Vertically mounted float switch with SPST open-on-rise switching action. Polypropylene construction with lead wire electrical connection. Requires minimum media specific gravity of 0.75. Used for high- or low-level detection in tanks and vessels for pump control or alarm triggering
MADISON
Vertically mounted float switch with SPST open-on-rise switching action. Polypropylene construction with lead wire electrical connection. Requires minimum media specific gravity of 0.75. Used for high- or low-level detection in tanks and vessels for pump control or alarm triggering
Vertically mounted float switch with brass construction and SPST contact that closes on rising liquid level. Features lead wire electrical connections. Requires minimum media specific gravity of 0.56. Suitable for level detection in tanks, reservoirs, and process equipment
MADISON
Vertically mounted float switch with brass construction and SPST contact that closes on rising liquid level. Features lead wire electrical connections. Requires minimum media specific gravity of 0.56. Suitable for level detection in tanks, reservoirs, and process equipment
Vertically mounted float switch with brass construction and SPST switch action that opens on rise. Features lead wires for electrical connection and requires a minimum media specific gravity of 0.56. Suitable for high- or low-level alarm and control in industrial tanks, such as sump pump control or overflow prevention
MADISON
Vertically mounted float switch with brass construction and SPST switch action that opens on rise. Features lead wires for electrical connection and requires a minimum media specific gravity of 0.56. Suitable for high- or low-level alarm and control in industrial tanks, such as sump pump control or overflow prevention
MADISON Closed Liquid Level Switch: Selectable, SPST, Brass (MPN M4300)
MADISON
MADISON Closed Liquid Level Switch: Selectable, SPST, Brass (MPN M4300)
MADISON Closed Liquid Level Switch: Close On Rise, SPST, Kynar (MPN M9000-ULL-NO)
MADISON
MADISON Closed Liquid Level Switch: Close On Rise, SPST, Kynar (MPN M9000-ULL-NO)