Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Pressure Plate - Fuse Blocks for UL Class RK1 & RK5 Fuses
MERSENFuse Blocks for UL Class RK1 & RK5 Fuses

MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Pressure Plate

The MERSEN 20326R is a 1-pole, open-block-design fuse block for UL Class RK1 and RK5 fuses, rated 250 V AC with a pressure-plate, non-indicating connection. 3G Electric interprets your demand for industrial…

SKU 3G-OTH-26746

Also listed as: 20326 R · 20326-R

Brand
MERSEN
Item
Fuse Block: Open Block Design, 1 Pole, 250 V AC, Pressure Plate
Category
Fuse Blocks for UL Class RK1 & RK5 Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

MERSEN
Manufacturer Part Number
20326R
Type
Pressure Plate, Non-Indicating
AC
250 V
Pole
1

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN 20326R is a 1-pole, open-block-design fuse block for UL Class RK1 and RK5 fuses, rated 250 V AC with a pressure-plate, non-indicating connection. 3G Electric interprets your demand for industrial electrical protection, sources this MERSEN component, and supports your application across 14 industrial departments — with specialist depth in controls to ensure the right solution.

Frequently Asked Questions

What is the MERSEN 20326R fuse block used for?

The MERSEN 20326R fuse block is used to safely mount and connect UL Class RK1 and RK5 fuses in industrial electrical circuits. It is commonly applied in motor control centers, panel boards, and distribution equipment requiring 250 V AC protection. The open block design and pressure plate terminals simplify wiring and maintenance.

What are the specifications of the MERSEN 20326R fuse block?

The MERSEN 20326R is a 1-pole, open block design fuse block rated for 250 V AC. It accepts UL Class RK1 and RK5 fuses and features pressure plate terminals for secure wire connections. The non-indicating design means no blown-fuse indicator is included. The manufacturer part number is 20326R.

Where to buy the MERSEN 20326R fuse block worldwide?

You can source the MERSEN 20326R fuse block through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time. 3G Electric supplies genuine MERSEN components for industrial applications.

How to install the MERSEN 20326R fuse block?

Mount the MERSEN 20326R fuse block on a flat surface using the provided slots. Strip wires to the recommended length, insert into pressure plate terminals, and tighten screws to the torque specified by MERSEN. Always de-energize circuits before installation and follow local electrical codes for fuse sizing and protection.

Used in

Common applications for MERSEN
Power electronics protection — MERSEN A70Q series semiconductor fuses in variable frequency drives for motor control.
Surge protection for industrial panels — MERSEN STP480D07 SPDs in three-phase 480V AC distribution boards.
Control circuit overcurrent protection — MERSEN ATM series midget fuses in PLC and instrumentation cabinets.
Power distribution in manufacturing — MERSEN FSPDB4A finger-safe blocks in motor control centers for wire management.
DC bus protection in renewable energy — MERSEN A30QS series fuses in solar inverter DC inputs.
High-voltage semiconductor protection — MERSEN A70Q series fuses in welding equipment power supplies.

MERSEN Products

3G Electric supplies MERSEN fuse blocks for ul class rk1 & rk5 fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20327R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20327R)
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20306R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20306R)
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20356R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20356R)
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20307R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20307R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20358R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20358R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20308R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20308R)

More from MERSEN

View all MERSEN parts
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60307R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60307R)
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20607R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20607R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Pressure Plate, Non-Indicating (MPN 60328R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Pressure Plate, Non-Indicating (MPN 60328R)
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 61036R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 61036R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 61038R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 61038R)
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60607R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60607R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60358R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60358R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20328R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20328R)