Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug - Fuse Blocks for UL Class RK1 & RK5 Fuses
MERSENFuse Blocks for UL Class RK1 & RK5 Fuses

MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug

MERSEN Fuse Blocks for UL Class RK1 & RK5 Fuses.

SKU 3G-OTH-25608

Also listed as: 20606 R · 20606-R

Brand
MERSEN
Item
Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug
Category
Fuse Blocks for UL Class RK1 & RK5 Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

MERSEN
Manufacturer Part Number
20606R

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

MERSEN Fuse Blocks for UL Class RK1 & RK5 Fuses.

Frequently Asked Questions

What is the MERSEN 20606R fuse block used for?

The MERSEN 20606R fuse block is used to safely mount and connect UL Class RK1 and RK5 fuses in industrial electrical circuits. It is commonly applied in motor control centers, panel boards, and distribution equipment requiring overcurrent protection at 250 V AC.

What are the specifications of the MERSEN 20606R fuse block?

The MERSEN 20606R is a 1-pole, open-block-design fuse block rated for 250 V AC. It features box-lug terminals and is non-indicating. It accepts UL Class RK1 and RK5 fuses. The manufacturer part number is 20606R.

Where to buy the MERSEN 20606R fuse block worldwide?

You can source the MERSEN 20606R fuse block through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time.

How to install the MERSEN 20606R fuse block?

Mount the MERSEN 20606R fuse block on a flat surface using the provided slots. Connect incoming and outgoing conductors to the box-lug terminals, torquing to the manufacturer's specification. Insert the correct Class RK1 or RK5 fuse. Always de-energize the circuit before installation.

Used in

Common applications for MERSEN
Power electronics protection — MERSEN A70Q series semiconductor fuses in variable frequency drives for motor control.
Surge protection for industrial panels — MERSEN STP480D07 SPDs in three-phase 480V AC distribution boards.
Control circuit overcurrent protection — MERSEN ATM series midget fuses in PLC and instrumentation cabinets.
Power distribution in manufacturing — MERSEN FSPDB4A finger-safe blocks in motor control centers for wire management.
DC bus protection in renewable energy — MERSEN A30QS series fuses in solar inverter DC inputs.
High-voltage semiconductor protection — MERSEN A70Q series fuses in welding equipment power supplies.

MERSEN Products

3G Electric supplies MERSEN fuse blocks for ul class rk1 & rk5 fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20306R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20306R)
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20356R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20356R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20358R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20358R)
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20307R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20307R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20308R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20308R)
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20326R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20326R)

More from MERSEN

View all MERSEN parts
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20328R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Pressure Plate, Non-Indicating (MPN 20328R)
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Pressure Plate, Non-Indicating (MPN 60327R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Pressure Plate, Non-Indicating (MPN 60327R)
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20657R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20657R)
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60357R)
MERSEN
MERSEN Fuse Block: Open Block Design, 2 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60357R)
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60306R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60306R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20608R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 20608R)
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60606R)
MERSEN
MERSEN Fuse Block: Open Block Design, 1 Pole, 600 V AC, Box Lug, Non-Indicating (MPN 60606R)
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 22003R)
MERSEN
MERSEN Fuse Block: Open Block Design, 3 Pole, 250 V AC, Box Lug, Non-Indicating (MPN 22003R)