Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.125 A, 500 V AC, 13/32 in x 1 1/2 in - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.125 A, 500 V AC, 13/32 in x 1 1/2 in

The MERSEN ATQ Series is a time-delay cylindrical fuse, specifically a midget fuse rated at 1.125 A and 500 V AC, with dimensions of 13/32 in x 1 1/2 in. This non-indicating fuse, model ATQ1-1/8, is designed for…

SKU 3G-OTH-25688

Also listed as: ATQ118 · ATQ1 1 8 · ATQ1-1-8

Brand
MERSEN
Item
Fuse: ATQ Series, Midget, Time-Delay, 1.125 A, 500 V AC, 13/32 in x 1 1/2 in
Category
Time-Delay Cylindrical Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

MERSEN
Manufacturer Part Number
ATQ1-1/8
Series
ATQ
Type
Midget, Time-Delay, 1.125 A, 13/32 in x 1 1/2 in, Non-Indicating
AC
500 V

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN ATQ Series is a time-delay cylindrical fuse, specifically a midget fuse rated at 1.125 A and 500 V AC, with dimensions of 13/32 in x 1 1/2 in. This non-indicating fuse, model ATQ1-1/8, is designed for overcurrent protection in industrial equipment.

Frequently Asked Questions

What is the MERSEN ATQ1-1/8 fuse used for?

The MERSEN ATQ1-1/8 is a time-delay midget fuse rated 1.125 A and 500 V AC. It provides overcurrent protection in industrial equipment such as control transformers, solenoids, and motor starters, where temporary inrush currents occur.

What are the specifications of the MERSEN ATQ1-1/8 fuse?

The MERSEN ATQ1-1/8 is a non-indicating, time-delay cylindrical fuse from the ATQ Series. It is rated 1.125 A, 500 V AC, with dimensions 13/32 in x 1 1/2 in. The manufacturer part number is ATQ1-1/8.

Where to buy MERSEN ATQ1-1/8 fuses worldwide?

3G Electric supplies the MERSEN ATQ1-1/8 fuse worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to select the correct MERSEN ATQ1-1/8 fuse for my application?

Select the MERSEN ATQ1-1/8 fuse based on your circuit's continuous current (1.125 A) and maximum voltage (500 V AC). Its time-delay characteristic handles temporary surges, making it suitable for inductive loads like transformers and motors.

Used in

Common applications for MERSEN
Power electronics protection — MERSEN A70Q series semiconductor fuses in variable frequency drives for motor control.
Surge protection for industrial panels — MERSEN STP480D07 SPDs in three-phase 480V AC distribution boards.
Control circuit overcurrent protection — MERSEN ATM series midget fuses in PLC and instrumentation cabinets.
Power distribution in manufacturing — MERSEN FSPDB4A finger-safe blocks in motor control centers for wire management.
DC bus protection in renewable energy — MERSEN A30QS series fuses in solar inverter DC inputs.
High-voltage semiconductor protection — MERSEN A70Q series fuses in welding equipment power supplies.

MERSEN Products

3G Electric supplies MERSEN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1)
MERSEN
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1)
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.25 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-1/4)
MERSEN
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.25 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-1/4)
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.5 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-1/2)
MERSEN
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.5 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-1/2)
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.6 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-6/10)
MERSEN
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.6 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-6/10)
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 2.125 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ2-1/8)
MERSEN
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 2.125 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ2-1/8)
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.8 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-8/10)
MERSEN
MERSEN Fuse: ATQ Series, Midget, Time-Delay, 1.8 A, 500 V AC, 13/32 in x 1 1/2 in, Non-Indicating (MPN ATQ1-8/10)

More from MERSEN

View all MERSEN parts
Class RK5 time-delay cylindrical fuse rated 15 A, 600 V AC, 300 V DC. Features an indicating function for quick identification of a blown fuse. Suitable for overcurrent protection in motor circuits, transformers, and other equipment that experiences inrush currents
MERSEN
Class RK5 time-delay cylindrical fuse rated 15 A, 600 V AC, 300 V DC. Features an indicating function for quick identification of a blown fuse. Suitable for overcurrent protection in motor circuits, transformers, and other equipment that experiences inrush currents
Midget time-delay fuse rated 200 mA at 250 V AC, with 13/32 in x 1 1/2 in dimensions. Indicating type for visual blown-fuse detection. Suitable for overcurrent protection in control circuits, instrumentation, and small motor loads where tolerance of inrush surges is required
MERSEN
Midget time-delay fuse rated 200 mA at 250 V AC, with 13/32 in x 1 1/2 in dimensions. Indicating type for visual blown-fuse detection. Suitable for overcurrent protection in control circuits, instrumentation, and small motor loads where tolerance of inrush surges is required
Time-delay cylindrical fuse rated 10 A, 250 V AC, with non-indicating design. Dimensions 1/4 in x 1 1/4 in. Equivalent to MDA and GSA series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits and power supplies
MERSEN
Time-delay cylindrical fuse rated 10 A, 250 V AC, with non-indicating design. Dimensions 1/4 in x 1 1/4 in. Equivalent to MDA and GSA series. Used for overcurrent protection in circuits with temporary inrush currents, such as motor circuits and power supplies
E-rated time-delay cylindrical fuse, 5 A, 4.8 kV AC, non-indicating. Designed for overcurrent protection in medium voltage industrial power systems, including motor circuits, transformers, and switchgear. The time-delay characteristic accommodates harmless inrush currents without nuisance opening
MERSEN
E-rated time-delay cylindrical fuse, 5 A, 4.8 kV AC, non-indicating. Designed for overcurrent protection in medium voltage industrial power systems, including motor circuits, transformers, and switchgear. The time-delay characteristic accommodates harmless inrush currents without nuisance opening
Class RK5 time-delay cylindrical fuse rated 30 A, 250 V AC, 160 V DC. Features an indicating function for visual blown-fuse detection. Suitable for overcurrent protection in industrial power distribution, motor, and transformer circuits where inrush currents require a time-delay characteristic
MERSEN
Class RK5 time-delay cylindrical fuse rated 30 A, 250 V AC, 160 V DC. Features an indicating function for visual blown-fuse detection. Suitable for overcurrent protection in industrial power distribution, motor, and transformer circuits where inrush currents require a time-delay characteristic
The MERSEN TR1/2R is a Class RK5 time-delay cylindrical fuse rated 500 mA at 250 V AC and DC. Part of the TR-R series, it is non-indicating and designed to protect circuits from overloads and short circuits while allowing temporary inrush currents. Typical applications include motor circuits, transformers, and lighting systems
MERSEN
The MERSEN TR1/2R is a Class RK5 time-delay cylindrical fuse rated 500 mA at 250 V AC and DC. Part of the TR-R series, it is non-indicating and designed to protect circuits from overloads and short circuits while allowing temporary inrush currents. Typical applications include motor circuits, transformers, and lighting systems
MERSEN ATQ Series time-delay cylindrical fuse, midget size, rated 1.4 A and 500 V AC. Dimensions 13/32 in x 1 1/2 in, non-indicating. Provides overcurrent protection for circuits with inrush currents, such as control panels, transformers, and motor circuits
MERSEN
MERSEN ATQ Series time-delay cylindrical fuse, midget size, rated 1.4 A and 500 V AC. Dimensions 13/32 in x 1 1/2 in, non-indicating. Provides overcurrent protection for circuits with inrush currents, such as control panels, transformers, and motor circuits
Time-delay cylindrical fuse from the TR-R series, rated 3.2 A, 250 V AC and 160 V DC. Class RK5, non-indicating design. Suitable for protecting circuits with inrush currents such as motor control centers, transformers, and lighting panels
MERSEN
Time-delay cylindrical fuse from the TR-R series, rated 3.2 A, 250 V AC and 160 V DC. Class RK5, non-indicating design. Suitable for protecting circuits with inrush currents such as motor control centers, transformers, and lighting panels