Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

MERSEN GDL Series Time-Delay Cylindrical Fuse, 10 A, 125 V AC, 1/4 in x 1 1/4 in - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

MERSEN GDL Series Time-Delay Cylindrical Fuse, 10 A, 125 V AC, 1/4 in x 1 1/4 in

The MERSEN GDL Series Time-Delay Cylindrical Fuse (MPN GDL10) is a 10 A, 125 V AC fuse with dimensions of 1/4 in x 1 1/4 in. This time-delay fuse from MERSEN is designed for overcurrent protection in industrial…

SKU 3G-OTH-27186

Also listed as: GDL 10 · GDL-10

Brand
MERSEN
Item
GDL Series Time-Delay Cylindrical Fuse, 10 A, 125 V AC, 1/4 in x 1 1/4 in
Category
Time-Delay Cylindrical Fuses
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

MERSEN
Manufacturer Part Number
GDL10
Series
GDL

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN GDL Series Time-Delay Cylindrical Fuse (MPN GDL10) is a 10 A, 125 V AC fuse with dimensions of 1/4 in x 1 1/4 in. This time-delay fuse from MERSEN is designed for overcurrent protection in industrial equipment.

Frequently Asked Questions

What is the MERSEN GDL10 fuse used for?

The MERSEN GDL10 is a 10 A, 125 V AC time-delay cylindrical fuse used for overcurrent protection in industrial equipment. Its time-delay characteristic allows it to withstand temporary inrush currents without nuisance tripping, making it suitable for motors, transformers, and control circuits.

What are the specifications of the MERSEN GDL10 fuse?

The MERSEN GDL10 is a GDL Series time-delay fuse rated 10 A at 125 V AC. It has a cylindrical body measuring 1/4 in x 1 1/4 in. The manufacturer part number is GDL10. This fuse is designed for reliable overcurrent protection in industrial applications.

Where to buy MERSEN GDL10 fuses worldwide?

3G Electric supplies MERSEN GDL10 fuses worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your location. Contact us to order the GDL10 or any MERSEN fuse for your overcurrent protection needs.

How to select the right MERSEN GDL fuse for my application?

To select the correct MERSEN GDL fuse, match the voltage rating (125 V AC) and current rating (10 A for GDL10) to your circuit requirements. Ensure the time-delay characteristic suits your equipment's inrush current. Consult the fuse's dimensions (1/4 in x 1 1/4 in) for holder compatibility.

Used in

Common applications for MERSEN
Power electronics protection — MERSEN A70Q series semiconductor fuses in variable frequency drives for motor control.
Surge protection for industrial panels — MERSEN STP480D07 SPDs in three-phase 480V AC distribution boards.
Control circuit overcurrent protection — MERSEN ATM series midget fuses in PLC and instrumentation cabinets.
Power distribution in manufacturing — MERSEN FSPDB4A finger-safe blocks in motor control centers for wire management.
DC bus protection in renewable energy — MERSEN A30QS series fuses in solar inverter DC inputs.
High-voltage semiconductor protection — MERSEN A70Q series fuses in welding equipment power supplies.

MERSEN Products

3G Electric supplies MERSEN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MERSEN GDL series time-delay cylindrical fuse rated 250 mA at 250 V AC. Physical size 1/4 in x 1 1/4 in. Designed for overcurrent protection in circuits with temporary inrush currents, such as motor starters, transformers, and control panels
MERSEN
MERSEN GDL series time-delay cylindrical fuse rated 250 mA at 250 V AC. Physical size 1/4 in x 1 1/4 in. Designed for overcurrent protection in circuits with temporary inrush currents, such as motor starters, transformers, and control panels
Time-delay cylindrical fuse rated 15 A at 125 V AC with a 1/4 in x 1 1/4 in body. Provides overcurrent protection for circuits with inductive loads such as motors and transformers that experience temporary inrush currents
MERSEN
Time-delay cylindrical fuse rated 15 A at 125 V AC with a 1/4 in x 1 1/4 in body. Provides overcurrent protection for circuits with inductive loads such as motors and transformers that experience temporary inrush currents
Time-delay cylindrical fuse rated 500 mA, 250 V AC with 1/4 in x 1 1/4 in body. Designed to tolerate temporary inrush currents without nuisance opening, suitable for circuits with brief startup surges
MERSEN
Time-delay cylindrical fuse rated 500 mA, 250 V AC with 1/4 in x 1 1/4 in body. Designed to tolerate temporary inrush currents without nuisance opening, suitable for circuits with brief startup surges
MERSEN GDL Series time-delay cylindrical fuse rated 1.25 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Designed for overcurrent protection in industrial equipment, suitable for motor circuits, transformers, and other inductive loads where temporary inrush currents occur
MERSEN
MERSEN GDL Series time-delay cylindrical fuse rated 1.25 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Designed for overcurrent protection in industrial equipment, suitable for motor circuits, transformers, and other inductive loads where temporary inrush currents occur
MERSEN GDL12 time-delay cylindrical fuse rated 12 A, 125 V AC with a physical size of 1/4 in x 1 1/4 in. Designed for overcurrent protection in industrial equipment such as motor circuits, transformers, and control panels, its time-delay characteristic accommodates temporary inrush currents without nuisance opening
MERSEN
MERSEN GDL12 time-delay cylindrical fuse rated 12 A, 125 V AC with a physical size of 1/4 in x 1 1/4 in. Designed for overcurrent protection in industrial equipment such as motor circuits, transformers, and control panels, its time-delay characteristic accommodates temporary inrush currents without nuisance opening
Time-delay cylindrical fuse rated 4 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, where temporary inrush currents occur
MERSEN
Time-delay cylindrical fuse rated 4 A, 250 V AC, with dimensions 1/4 in x 1 1/4 in. Designed for overcurrent protection in circuits with inductive loads such as motors and transformers, where temporary inrush currents occur

More from MERSEN

View all MERSEN parts
Class RK5 time-delay cylindrical fuse rated 1.25 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristic for motor and equipment protection. Suitable for overcurrent protection in industrial control panels, HVAC systems, and pump controls
MERSEN
Class RK5 time-delay cylindrical fuse rated 1.25 A at 600 V AC and 600 V DC. Non-indicating design with time-delay characteristic for motor and equipment protection. Suitable for overcurrent protection in industrial control panels, HVAC systems, and pump controls
Time-delay midget fuse rated 6 A and 250 V AC, with dimensions 13/32 in x 1 1/2 in. Non-indicating design. Suitable for protecting circuits with inrush currents in control panels, motor starters, and lighting systems
MERSEN
Time-delay midget fuse rated 6 A and 250 V AC, with dimensions 13/32 in x 1 1/2 in. Non-indicating design. Suitable for protecting circuits with inrush currents in control panels, motor starters, and lighting systems
MERSEN GFN Series midget time-delay fuse rated 20 A at 32 V AC. Dimensions 13/32 in x 1 1/2 in. Indicating type for visual blown-fuse identification. Used in control panels and industrial equipment for overcurrent protection with tolerance to inrush currents
MERSEN
MERSEN GFN Series midget time-delay fuse rated 20 A at 32 V AC. Dimensions 13/32 in x 1 1/2 in. Indicating type for visual blown-fuse identification. Used in control panels and industrial equipment for overcurrent protection with tolerance to inrush currents
Class RK5, TR-R series time-delay fuse rated 2.5 A at 250 V AC and 250 V DC. Non-indicating cylindrical body. Designed for branch-circuit protection in motor circuits, control panels, and equipment with high inrush currents
MERSEN
Class RK5, TR-R series time-delay fuse rated 2.5 A at 250 V AC and 250 V DC. Non-indicating cylindrical body. Designed for branch-circuit protection in motor circuits, control panels, and equipment with high inrush currents
Time-delay cylindrical fuse from MERSEN GDG Series, rated 8 A and 250 V AC. Body dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits with temporary inrush currents, such as control panels, motor circuits, and power supplies
MERSEN
Time-delay cylindrical fuse from MERSEN GDG Series, rated 8 A and 250 V AC. Body dimensions 5.1 mm x 20.1 mm. Provides overcurrent protection in circuits with temporary inrush currents, such as control panels, motor circuits, and power supplies
MERSEN A6D Series Class RK1 time-delay cylindrical fuse, rated 300 mA at 600 V AC and 600 V DC. Non-indicating design for overcurrent protection in industrial circuits, such as motor and transformer branch circuits where inrush currents occur
MERSEN
MERSEN A6D Series Class RK1 time-delay cylindrical fuse, rated 300 mA at 600 V AC and 600 V DC. Non-indicating design for overcurrent protection in industrial circuits, such as motor and transformer branch circuits where inrush currents occur
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
MERSEN
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
The MERSEN TR20R is a Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. It is part of the TR-R Series and is non-indicating. This fuse provides overcurrent protection for motor circuits, transformers, and lighting systems, allowing temporary inrush currents without nuisance opening
MERSEN
The MERSEN TR20R is a Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. It is part of the TR-R Series and is non-indicating. This fuse provides overcurrent protection for motor circuits, transformers, and lighting systems, allowing temporary inrush currents without nuisance opening