Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
MERSEN TR15/100R Time-Delay Cylindrical Fuse, Class RK5, 150 mA, 250 V AC/DC - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

MERSEN TR15/100R Time-Delay Cylindrical Fuse, Class RK5, 150 mA, 250 V AC/DC

The MERSEN TR-R Series Class RK5 Time-Delay Cylindrical Fuse (MPN TR15/100R) is a 150 mA, non-indicating fuse rated for 250 V AC and 250 V DC. 3G Electric interprets your demand for industrial circuit protection…

SKU 3G-OTH-26817

Also listed as: TR15100R · TR15 100R · TR15-100R

Brand
MERSEN
Item
TR15/100R Time-Delay Cylindrical Fuse, Class RK5, 150 mA, 250 V AC/DC
Part Number
TR15/100R
Category
Time-Delay Cylindrical Fuses
Available to Order
Also known as:TR15/100RMERSEN
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

MERSEN
Manufacturer Part Number
TR15/100R
Series
TR-R
Type
TR-R Series, Time-Delay, 150 mA, Non-Indicating
AC
250 V
DC
250 V

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN TR-R Series Class RK5 Time-Delay Cylindrical Fuse (MPN TR15/100R) is a 150 mA, non-indicating fuse rated for 250 V AC and 250 V DC. 3G Electric interprets your demand for industrial circuit protection, sourcing this OEM fuse across 14 departments — with specialist depth in electrical controls to ensure the right solution.

Frequently Asked Questions

What is a MERSEN TR15/100R fuse used for?

The MERSEN TR15/100R is a Class RK5, time-delay cylindrical fuse rated 150 mA at 250 V AC/DC. It protects motor circuits, transformers, and lighting systems from overcurrent while tolerating harmless inrush surges. Common in industrial control panels and HVAC equipment.

What are the specifications of the MERSEN TR15/100R fuse?

The MERSEN TR15/100R is a Class RK5, TR-R series, time-delay, non-indicating fuse. It is rated 150 mA, 250 V AC, and 250 V DC. The manufacturer part number is TR15/100R. It provides reliable overcurrent protection for sensitive industrial circuits.

Where to buy MERSEN TR15/100R fuses worldwide?

3G Electric supplies the MERSEN TR15/100R fuse to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial sourcing partner, we provide genuine MERSEN circuit protection components for demanding applications.

How to select the correct MERSEN TR-R series fuse for a circuit?

Select a MERSEN TR-R series fuse by matching voltage (250 V AC/DC), current rating (150 mA for TR15/100R), and interrupting rating to your circuit. Time-delay fuses handle motor start-ups. Verify the Class (RK5) meets your branch-circuit protection requirements per NEC/CEC.

Used in

Common applications for MERSEN
Industrial control panels — Mersen USCC1 and USCC2 UL Class CC fuse blocks for DIN rail mounting and finger-safe branch circuit protection.
Motor starters — Mersen ATQ time-delay fuses and DAR0 R-rated fuses for motor overload and short-circuit protection.
Power supplies and instrumentation — Mersen GGM and GSB fast-acting cylindrical fuses for overcurrent protection in compact electronic circuits.
DC systems — Mersen A30QS very-fast-acting square fuses rated 300 V DC for semiconductor and DC equipment protection.
Medium-voltage distribution — Mersen DAR0 R-rated fuses rated 5.08 kV AC for general-purpose overcurrent protection with visual indication.
Not sure this is the right part? Photo-identify it→

MERSEN Products

3G Electric supplies MERSEN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from MERSEN

View all MERSEN parts →
Class RK5 time-delay cylindrical fuse rated 1.125 A at 250 V AC and 250 V DC. Non-indicating type from the TR-R series. Designed for overload and short-circuit protection in circuits with inrush currents, such as motor control centers, panel boards, and branch circuits
MERSEN
Class RK5 time-delay cylindrical fuse rated 1.125 A at 250 V AC and 250 V DC. Non-indicating type from the TR-R series. Designed for overload and short-circuit protection in circuits with inrush currents, such as motor control centers, panel boards, and branch circuits
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
MERSEN
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
MERSEN
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. Features visual indication for blown fuse detection. Used for motor and transformer protection in industrial control panels, switchgear, and distribution equipment requiring inrush current tolerance and overload protection
MERSEN
Class RK5 time-delay cylindrical fuse rated 20 A, 250 V AC and 160 V DC. Features visual indication for blown fuse detection. Used for motor and transformer protection in industrial control panels, switchgear, and distribution equipment requiring inrush current tolerance and overload protection
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
MERSEN
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents
MERSEN
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents
Time-delay cylindrical fuse rated 5 A and 250 V AC with a non-indicating 5 mm x 20 mm body. Suitable for overcurrent protection in industrial equipment, power supplies, and control panels where delayed response to transient surges is required. Equivalent to S505, 477, and GSF fuse series
MERSEN
Time-delay cylindrical fuse rated 5 A and 250 V AC with a non-indicating 5 mm x 20 mm body. Suitable for overcurrent protection in industrial equipment, power supplies, and control panels where delayed response to transient surges is required. Equivalent to S505, 477, and GSF fuse series
Time-delay cylindrical fuse rated 125 mA at 600 V AC. Dual-element design with melamine body, non-indicating, 13/32 in x 1 1/2 in. Suited for control transformers and solenoids in industrial circuits
MERSEN
Time-delay cylindrical fuse rated 125 mA at 600 V AC. Dual-element design with melamine body, non-indicating, 13/32 in x 1 1/2 in. Suited for control transformers and solenoids in industrial circuits

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first