Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
MERSEN TRS5R Class RK5 Time-Delay Cylindrical Fuse - Time-Delay Cylindrical Fuses
MERSENTime-Delay Cylindrical Fuses

MERSEN TRS5R Class RK5 Time-Delay Cylindrical Fuse

The MERSEN TRS-R Series TRS5R is a Class RK5 time-delay cylindrical fuse rated for 5 A at 600 V AC and 600 V DC. This non-indicating fuse is designed for overcurrent protection in industrial electrical systems…

SKU 3G-OTH-27626

Brand
MERSEN
Item
TRS5R Class RK5 Time-Delay Cylindrical Fuse
Part Number
TRS5R
Category
Time-Delay Cylindrical Fuses
Available to Order
Also known as:TRS5RMERSEN
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

MERSEN
Manufacturer Part Number
TRS5R
Series
TRS-R
Type
TRS-R Series, Time-Delay, 5 A, Non-Indicating
AC
600 V
DC
600 V

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

MERSEN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The MERSEN TRS-R Series TRS5R is a Class RK5 time-delay cylindrical fuse rated for 5 A at 600 V AC and 600 V DC. This non-indicating fuse is designed for overcurrent protection in industrial electrical systems, supporting reliable operation across 14 departments including electrical and instrumentation.

Frequently Asked Questions

What is the MERSEN TRS5R fuse used for?

The MERSEN TRS5R is a Class RK5 time-delay cylindrical fuse rated 5 A, 600 V AC/DC. It protects industrial circuits with high inrush currents, such as motors, transformers, and lighting systems, by allowing temporary overloads without nuisance opening.

What are the specifications of the MERSEN TRS5R fuse?

The MERSEN TRS5R is part of the TRS-R series, a Class RK5 time-delay fuse. It is rated 5 A, 600 V AC and 600 V DC, non-indicating. The manufacturer part number is TRS5R, and it is designed for overcurrent protection in industrial equipment.

Where to buy MERSEN TRS5R fuses worldwide?

You can source MERSEN TRS5R fuses through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring reliable supply for your maintenance or project needs.

How to select the correct MERSEN TRS5R fuse for an application?

To select the MERSEN TRS5R, verify the circuit voltage (up to 600 V AC/DC) and continuous current (5 A). Ensure the Class RK5 time-delay characteristic matches your equipment's inrush profile. Consult the manufacturer's data sheet for interrupting rating and coordination with downstream devices.

Used in

Common applications for MERSEN
Industrial control panels — Mersen USCC1 and USCC2 UL Class CC fuse blocks for DIN rail mounting and finger-safe branch circuit protection.
Motor starters — Mersen ATQ time-delay fuses and DAR0 R-rated fuses for motor overload and short-circuit protection.
Power supplies and instrumentation — Mersen GGM and GSB fast-acting cylindrical fuses for overcurrent protection in compact electronic circuits.
DC systems — Mersen A30QS very-fast-acting square fuses rated 300 V DC for semiconductor and DC equipment protection.
Medium-voltage distribution — Mersen DAR0 R-rated fuses rated 5.08 kV AC for general-purpose overcurrent protection with visual indication.
Not sure this is the right part? Photo-identify it→

MERSEN Products

3G Electric supplies MERSEN time-delay cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from MERSEN

View all MERSEN parts →
Class RK5 time-delay cylindrical fuse rated 1.125 A at 250 V AC and 250 V DC. Non-indicating type from the TR-R series. Designed for overload and short-circuit protection in circuits with inrush currents, such as motor control centers, panel boards, and branch circuits
MERSEN
Class RK5 time-delay cylindrical fuse rated 1.125 A at 250 V AC and 250 V DC. Non-indicating type from the TR-R series. Designed for overload and short-circuit protection in circuits with inrush currents, such as motor control centers, panel boards, and branch circuits
Time-delay midget fuse rated 1.25 A and 250 V AC, with dimensions 13/32 in x 1 1/2 in. Non-indicating design. Used for overcurrent protection in control transformers, solenoids, and other inductive loads where temporary inrush currents occur
MERSEN
Time-delay midget fuse rated 1.25 A and 250 V AC, with dimensions 13/32 in x 1 1/2 in. Non-indicating design. Used for overcurrent protection in control transformers, solenoids, and other inductive loads where temporary inrush currents occur
Class RK5 time-delay cylindrical fuse rated 17.5 A, 250 V AC and 160 V DC. The indicating feature provides visual confirmation of a blown fuse. Suitable for motor circuits, transformers, and lighting systems where temporary inrush currents occur
MERSEN
Class RK5 time-delay cylindrical fuse rated 17.5 A, 250 V AC and 160 V DC. The indicating feature provides visual confirmation of a blown fuse. Suitable for motor circuits, transformers, and lighting systems where temporary inrush currents occur
Midget time-delay cylindrical fuse rated 1 A at 250 V AC. Body size 13/32 in x 1 1/2 in with indicating feature for blown fuse identification. Used for overcurrent protection in control circuits, transformers, and solenoids
MERSEN
Midget time-delay cylindrical fuse rated 1 A at 250 V AC. Body size 13/32 in x 1 1/2 in with indicating feature for blown fuse identification. Used for overcurrent protection in control circuits, transformers, and solenoids
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
MERSEN
Time-delay cylindrical fuse from the ATQ Series, rated 8 A and 500 V AC. Midget size with 13/32 in x 1 1/2 in dimensions and non-indicating design. Provides overload and short-circuit protection for circuits that experience temporary inrush currents, such as control transformers and motor starters
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
MERSEN
Midget time-delay fuse rated 100 mA at 250 V AC. Measures 13/32 in x 1 1/2 in with indicating feature for visual blown-fuse identification. Provides overcurrent protection in circuits such as control transformers, solenoids, and instrumentation where temporary inrush currents occur
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
MERSEN
MERSEN GDG Series time-delay cylindrical fuse rated 2.5 A, 250 V AC. Physical dimensions are 5.1 mm x 20.1 mm. Designed for overcurrent protection in industrial equipment such as control panels, motor circuits, and power supplies where tolerance to inrush currents is required
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents
MERSEN
Class RK1 time-delay cylindrical fuse rated 30 A at 250 V AC and 250 V DC. Features indicating function for blown fuse detection. Suitable for overcurrent protection in motor circuits, transformers, and other equipment with inrush currents

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first