Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

NEXTTEQ Detector Tube: NEXTEQ NX-1000, C7H14O, Gas Detection Tube, With Pump, 5 to 200 ppm - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ Detector Tube: NEXTEQ NX-1000, C7H14O, Gas Detection Tube, With Pump, 5 to 200 ppm

The NEXTTEQ NX-1000 Detector Tube (MPN NX182) is a C7H14O gas detection tube for use with NEXTTEQ NX-1000 pumps, supplied in packs of 10. It detects Methyl Cyclohexanol across a range of 5 to 200 ppm, enabling…

SKU 3G-OTH-602268

Brand
NEXTTEQ
Item
Detector Tube: NEXTEQ NX-1000, C7H14O, Gas Detection Tube, With Pump, 5 to 200 ppm
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX182
Type
C7H14O, Gas Detection Tube, With Pump, 5 to 200 ppm, 10 PK
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX182) is a C7H14O gas detection tube for use with NEXTTEQ NX-1000 pumps, supplied in packs of 10. It detects Methyl Cyclohexanol across a range of 5 to 200 ppm, enabling precise measurement of this specific compound in industrial environments.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX182) is used to measure Methyl Cyclohexanol (C7H14O) in industrial air. It works with the NEXTTEQ NX-1000 pump to detect concentrations from 5 to 200 ppm, helping plant engineers and safety teams monitor exposure in chemical processing or manufacturing environments.

What are the specifications of the NEXTTEQ NX-1000 detector tube?

The NEXTTEQ NX-1000 detector tube (NX182) detects Methyl Cyclohexanol (C7H14O) over a range of 5 to 200 ppm. It is designed for use with the NEXTTEQ NX-1000 pump and is supplied in packs of 10. The tube enables precise, on-site gas measurement for industrial hygiene and safety applications.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies the NEXTTEQ NX-1000 detector tube (NX182) to customers worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance for international orders. Contact us to source this gas detection tube for your facility, regardless of your location.

How to use the NEXTTEQ NX-1000 detector tube with the pump?

To use the NEXTTEQ NX-1000 detector tube, break off both tips, insert it into the NEXTTEQ NX-1000 pump, and follow the pump's stroke instructions. The tube's color change indicates Methyl Cyclohexanol concentration from 5 to 200 ppm. Always refer to the manufacturer's manual for proper handling and storage.

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from NEXTTEQ

View all NEXTTEQ parts
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H8O, Gas Detection Tube, Isopropyl Alcohol ( C3H8O ), 10 PK (MPN NX175). Key specifications — attr914051: Isopropyl Alcohol; attr914053: 20 to 480 ppm/50 to 1,200 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H8O, Gas Detection Tube, Isopropyl Alcohol ( C3H8O ), 10 PK (MPN NX175). Key specifications — attr914051: Isopropyl Alcohol; attr914053: 20 to 480 ppm/50 to 1,200 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN NX108VL). Key specifications — attr914051: Ammonia; attr914053: 0.2 to 4 ppm/0.5 to 10 ppm/1 to 20 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, NH3, Gas Detection Tube, Ammonia ( NH3 ), With Pump, 10 PK (MPN NX108VL). Key specifications — attr914051: Ammonia; attr914053: 0.2 to 4 ppm/0.5 to 10 ppm/1 to 20 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H5NH2, Gas Detection Tube, Aniline ( C6H5NH2 ), 10 PK (MPN NX109). Key specifications — attr914051: Aniline; attr914053: 1 to 15 ppm/2 to 30 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C6H5NH2, Gas Detection Tube, Aniline ( C6H5NH2 ), 10 PK (MPN NX109). Key specifications — attr914051: Aniline; attr914053: 1 to 15 ppm/2 to 30 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, NO, Gas Detection Tube, With Pump, Industrial Hygiene, 5 PK (MPN NX195C). Key specifications — attr914051: Nitrogen Oxide; attr914053: Nitric Oxide (10 to 300 ppm)/Nitrogen Dioxide (1 to 40 ppm).
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, NO, Gas Detection Tube, With Pump, Industrial Hygiene, 5 PK (MPN NX195C). Key specifications — attr914051: Nitrogen Oxide; attr914053: Nitric Oxide (10 to 300 ppm)/Nitrogen Dioxide (1 to 40 ppm).
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H2, Gas Detection Tube, Acetylene ( C2H2 ), 10 PK (MPN NX104). Key specifications — attr914051: Acetylene; attr914053: 50 to 1,000 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C2H2, Gas Detection Tube, Acetylene ( C2H2 ), 10 PK (MPN NX104). Key specifications — attr914051: Acetylene; attr914053: 50 to 1,000 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H4Cl2, Gas Detection Tube, With Pump, 0.5 to 10 ppm, 5 PK (MPN NX140). Key specifications — attr914051: Dichloropropene; attr914053: 0.5 to 10 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C3H4Cl2, Gas Detection Tube, With Pump, 0.5 to 10 ppm, 5 PK (MPN NX140). Key specifications — attr914051: Dichloropropene; attr914053: 0.5 to 10 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C5H6O2, Gas Detection Tube, With Pump, 5 to 25 ppm, 10 PK (MPN NX158). Key specifications — attr914051: Furfuryl Alcohol; attr914053: 5 to 25 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C5H6O2, Gas Detection Tube, With Pump, 5 to 25 ppm, 10 PK (MPN NX158). Key specifications — attr914051: Furfuryl Alcohol; attr914053: 5 to 25 ppm.
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C8H10, Gas Detection Tube, Ethyl Benzene ( C8H10 ), 10 PK (MPN NX149). Key specifications — attr914051: Ethyl Benzene; attr914053: 10 to 500 ppm.
NEXTTEQ
NEXTTEQ Detector Tube: NEXTEQ NX-1000, C8H10, Gas Detection Tube, Ethyl Benzene ( C8H10 ), 10 PK (MPN NX149). Key specifications — attr914051: Ethyl Benzene; attr914053: 10 to 500 ppm.